Nabertherm QS 30
Nabertherm QS 30 — Salt Bath Furnaces.
The QS 30 is a 1-phase electrically heated salt bath furnace for martempering in neutral salts, with a maximum operating temperature of 550 °C and a charging basket work space of 300 × 230 × 580 mm. It holds a minimum salt volume of 30 (unit as printed) and accepts a maximum charge weight of 5 (unit as printed), positioning it as the mid-size unit between the QS 20 and QS 70 siblings. It is intended for isothermal heat-treatment steps where the workload is quenched into the molten salt bath and held at temperature.
Nabertherm QS Series — Model Comparison & Selection
Full specifications
| Electrical connection | 1-phase |
| min. amount of salt mfr | 30 |
| Heating mfr | 3,2 |
| Outer dimensions (W × D × H) mfr | 800 × 600 × 1020 mm |
| Weight | 165 kg |
| max. charge weight mfr | 5 |
| Work space dimensions in the charging basketin mm mfr | 300 |
| Work space dimensions in the charging basketin mm mfr | 230 |
| Work space dimensions in the charging basketin mm mfr | 580 |
| Max temperature | 550 °C |
Description
Construction and series positioning
- The QS 30 is a floor-standing salt bath furnace with outer dimensions of 800 × 600 × 1020 mm and a weight of 165 kg; the heated work space is defined by the charging basket at 300 × 230 × 580 mm.
- Within the QS series it sits between the smaller QS 20 and the larger QS 70; the 30 in the model code refers to the minimum salt amount (30, unit as printed), not to a power or voltage rating.
- Heating is electric, 1-phase; the heating value is printed as 3,2 without a unit in the factory data and is therefore not restated here as a power rating.
Process behaviour
- Maximum bath temperature is 550 °C, consistent with neutral-salt martempering duty; the maximum charge weight is 5 (unit as printed), so workload mass must be checked against this limit before each cycle.
- No digitized curve points were supplied for this model, so heat-up and cooling behaviour cannot be quantified from the available facts; the charge-weight and salt-volume limits are the governing process constraints.
Control and operation
- The attached controller document covers the Nabertherm 500 series and MyNabertherm app, including process data storage and AMS2750F instrumentation types, but it prints no QS-specific wiring or setpoint data; controller configuration must therefore be confirmed against the furnace order documentation.
- The remaining attached digests (fiber optics, foundry, dental) cover other product lines and contain no QS 30-specific installation facts.
Integration & Operating Notes
The furnace is specified for 1-phase connection. Because the factory data give the heating value without a unit, the actual connected load and required protective device cannot be derived from this card; obtain the nameplate or order-specific circuit diagram before preparing the feed cable and breaker.
The maximum charge weight is listed as 5 with no unit in the factory data. Exceeding the charge limit in a salt bath risks bath overflow and splashing of molten salt; the permissible mass must be confirmed in the unit stated on the order documents before loading.
The minimum salt amount is 30 (unit as printed). Operating below this fill level leaves the heating elements insufficiently immersed, which affects temperature uniformity and can overheat the bath; the fill level must be checked before each heat-up.
The controller digest describes the 500 series and MyNabertherm app, process data storage and AMS2750F instrumentation types, but prints no QS 30-specific parameters. Recorder and controller options must be selected from the furnace order documentation rather than from the generic controller brochure.
Selection & Integration Q&A
Pick the QS 30 when the charging basket work space of 300 × 230 × 580 mm and a maximum charge weight of 5 (unit as printed) fit the workload. The QS 20 is the smaller sibling for lighter charges; the QS 70 is the larger one for heavier workloads. All three share the 550 °C maximum temperature.
The furnace is a 1-phase unit, but the factory data give the heating value as 3,2 without a unit, so the connected load cannot be read from this card. Size the feed cable and breaker from the nameplate or order-specific circuit diagram, and confirm the plant provides a single-phase circuit at the installed location.
Keep the charge at or below the maximum charge weight of 5 (unit as printed) and maintain at least the minimum salt amount of 30 (unit as printed). Both limits are printed without units in the factory data, so confirm the stated units on the order documents before the first cycle.
The supplied documents do not list a controller, recorder or cabling as part of the base delivery; the controller brochure covers the 500 series and MyNabertherm app as options. Confirm the ordered scope, including any AMS2750F instrumentation type, against the order confirmation before commissioning.