Nabertherm VHT 100/..
Nabertherm VHT 100/.. — Cold Wall Retort Furnaces.
The VHT 100/.. is a cold-wall retort furnace with a 100 l chamber and a 450 × 550 × 450 mm work space, rated for a maximum charge of 75 kg. It is the mid-size unit in the VHT series, between the VHT 40/.. and VHT 500/.., intended for high-temperature batch processing under controlled atmosphere or vacuum.
Nabertherm VHT Series — Model Comparison & Selection
| Model | Chamber volume, L |
|---|---|
| VHT 100/.. Current | 100 |
| VHT 40/.. | 40 |
| VHT 500/.. | 500 |
Full specifications
| Chamber volume | 100 l |
| Work space in mm mfr | 450 |
| Max. charge mfr | 75 |
| Heating power in kW4 mfr | 85 |
| Outer dimensions (W × D × H) mfr | 1900 × 35005 × 2500 mm |
| Inner dimensions (W × D × H) mfr | 425 × 500 × 425 mm |
Description
Construction and series positioning
- Cold-wall retort design with a 100 l chamber volume and a work space of 450 × 550 × 450 mm (W × D × H).
- Maximum charge is 75 kg, which sets the batch mass limit for the retort and hearth.
- Within the VHT series, this model sits between the VHT 40/.. and the VHT 500/..; it is the choice when the 40-litre chamber is too small for the batch geometry but the 500-litre unit would be oversized.
- The outer dimensions are 1900 × 3500 × 2500 mm (W × D × H); the depth figure carries a footnote marker in the source data and should be confirmed against the dimension drawing before layout.
Heating power and configuration space
- Heating power is not a single value for this model: the source lists 131/155/175 kW, 90/140 kW, 85 kW and 'on request' against the same model code, with footnote markers. These are configuration-dependent ratings, not interchangeable specifications.
- Because the heating power varies by configuration, the electrical supply, protection and cable sizing must be fixed only after the specific configuration is ordered; do not size the supply from a single figure in the table.
- No digitized curves are available for this model, so heat-up and cooling behaviour cannot be stated here; they must be taken from the order-specific documentation.
Control and documentation
- The attached controller documentation covers the Nabertherm 500 controller series and the MyNabertherm app, including process data storage and temperature uniformity instrumentation types (AMS2750F). It does not print furnace model sizes or ordering codes, so controller assignment must be confirmed per order.
- The other attached brochures (fiber optics glass, foundry, dental) cover different product lines and contain no facts specific to this furnace; they are not a basis for specifying the VHT 100/...
Gaps in the verified data
- No certifications and no applications are listed for this model. No process media, atmosphere or vacuum data, no connection sizes and no installation clearances are present in the verified facts. These must come from the order-specific manual and drawing set.
Integration & Operating Notes
The maximum charge of 75 kg applies to the retort and its loading. Exceeding it overloads the retort and hearth and is outside the verified specification; the charge weight must include fixtures and any baskets, not only the parts.
The outer dimensions are given as 1900 × 3500 × 2500 mm, but the depth value carries a footnote marker in the source data. Floor layout, door swing and service access should be planned from the order-specific dimension drawing rather than from this table row alone.
Selection & Integration Q&A
Pick the VHT 100/.. when the batch fits the 450 × 550 × 450 mm work space and stays under 75 kg but is too large for the VHT 40/... The VHT 500/.. is for larger batches; using it for small loads wastes chamber volume and energy.
The heating power is configuration-dependent (131/155/175 kW, 90/140 kW, 85 kW or on request), so the supply voltage, current and protection cannot be fixed until the exact configuration is chosen. Confirm the rating with the order before routing cables.
The verified facts list no included controller, recorder, thermocouples or cables. The controller documentation describes the 500 series and MyNabertherm app as options but names no furnace model, so controller, recorder and sensor scope must be confirmed from the order confirmation.