No photo available yet
Nabertherm VHT 500/..
Nabertherm VHT 500/.. — Cold Wall Retort Furnaces.
The VHT 500/.. is a cold-wall retort furnace with a 500 l chamber and a 750 × 900 × 750 mm work space, positioned at the upper end of the VHT series above the VHT 100/.. and VHT 40/.. siblings. Its heating power is configuration-dependent (220/260 kW or on request), and it is intended for high-temperature batch processing under controlled atmosphere or vacuum.
Nabertherm VHT Series — Model Comparison & Selection
| Model | Chamber volume, L |
|---|---|
| VHT 500/.. Current | 500 |
| VHT 100/.. | 100 |
| VHT 40/.. | 40 |
Full specifications
| Chamber volume | 500 l |
| Work space in mm mfr | 750 |
| Max. charge mfr | 350 |
| Heating power in kW4 mfr | on request |
| Outer dimensions (W × D × H) mfr | 32001 × 4500 × 3300 mm |
| Inner dimensions (W × D × H) mfr | 725 × 850 × 725 mm |
Description
Construction and series positioning
- Cold-wall retort design with a 500 l chamber volume and a work space of 750 × 900 × 750 mm (W × D × H).
- Maximum charge weight is 350 kg.
- Within the VHT series, this is the largest listed modification; the VHT 100/.. and VHT 40/.. are smaller-chamber siblings. Select the VHT 500/.. when batch volume and charge mass exceed the capacity of those smaller units.
- Outer dimensions are 3200 × 4500 × 3300 mm (W × D × H), requiring substantial floor space and height clearance.
Thermal and electrical configuration
- Heating power is not a single fixed value: the specification lists 220/260 kW and further ratings as "on request". The actual heating power must be confirmed per order configuration; no single rating should be assumed.
- No digitized curve points or verified temperature-range data are available for this model, so heat-up rates and uniformity cannot be stated here.
Control and documentation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process data storage and AMS2750F instrumentation types, but does not print model-specific settings for the VHT 500/..
- No furnace-specific manual digest with installation, connection or operating sequences was provided; those details must be taken from the model-specific instruction manual at commissioning.
Integration & Operating Notes
The outer dimensions leave little margin for service access, charge loading equipment and cable routing. Verify door swing, crane or hoist approach and maintenance clearance around the full envelope before committing the foundation and building height.
The maximum charge is 350 kg. Exceeding it loads the retort and hearth beyond their design basis; distribute the charge evenly and account for fixture weight, not only the workload, when checking against this limit.
Selection & Integration Q&A
Choose the VHT 500/.. when the batch requires a 500 l chamber and a work space of 750 × 900 × 750 mm with charges up to 350 kg. The VHT 100/.. and VHT 40/.. are smaller-chamber siblings; use them when batch volume and charge mass fit their smaller work spaces.
The heating power is configuration-dependent: the sheet lists 220/260 kW and further ratings as 'on request'. Confirm the ordered rating in writing before sizing transformers, protection and cables. Controller type and instrumentation (e.g. AMS2750F) are selected from the 500-series controller range.
The furnace occupies 3200 × 4500 × 3300 mm (W × D × H), so floor area, height clearance and access for loading equipment must be planned around that envelope. The maximum charge is 350 kg, including fixtures. No furnace-specific manual digest was supplied, so confirm clearances and foundation loads with Nabertherm.
No furnace-specific maintenance schedule, service intervals or base-delivery accessory list is included in the supplied documents. The controller brochure covers the 500-series controllers and MyNabertherm app but not consumables or cables. Request the VHT 500/.. instruction manual and spare-parts list from Nabertherm before commissioning.