Technical Data Sheet — G-BH2 2BH20360-2 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH2 0360-2: side channel blower in ATEX configuration (G-BH2 N / VELOCIS), ATEX categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; 3/2G only as 50 Hz or 60 Hz versions. Ordering code 2BH2….-….□-Z with Z=M74.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 50 Hz p.2 ↗ | 2BH20360-2, 50 Hz |
| Voltage | 230 ∆/ 400 Y V p.2 ↗ | 2BH20360-2, 50 Hz |
| Current | 22,5 ∆/ 13,1 Y A p.2 ↗ | 2BH20360-2, 50 Hz |
| Power | 7,5 kW p.2 ↗ | 2BH20360-2, 50 Hz |
| Max. differential pressure | 550 mbar p.2 ↗ | 2BH20360-2, 50 Hz |
| Vacuum | -380 mbar p.2 ↗ | 2BH20360-2, 50 Hz |
| Sound level | 70 dB(A) p.2 ↗ | 2BH20360-2, 50 Hz |
| Weight | 113 kg p.2 ↗ | 2BH20360-2, 50 Hz |
| Protection class | IP55 p.2 ↗ | 2BH20360-2 |
| Rated frequency | 60 Hz p.2 ↗ | 2BH20360-2, 60 Hz |
| Voltage | 460 Y V p.2 ↗ | 2BH20360-2, 60 Hz |
| Current | 13,0 Y A p.2 ↗ | 2BH20360-2, 60 Hz |
| Power | 8,6 kW p.2 ↗ | 2BH20360-2, 60 Hz |
| Max. differential pressure | 550 mbar p.2 ↗ | 2BH20360-2, 60 Hz |
| Vacuum | -380 mbar p.2 ↗ | 2BH20360-2, 60 Hz |
| Sound level | 76 dB(A) p.2 ↗ | 2BH20360-2, 60 Hz |
| Weight | 113 kg p.2 ↗ | 2BH20360-2, 60 Hz |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Frequency tolerance: +/- 2 % maximum p.2 ↗
- Protection class: IP55 p.2 ↗
- ATEX category 3GD temperature class: II 3G IIB T3 Gc and II 3D IIIB T125°C Dc p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series / type: side channel blower G-BH2 |
| 5-8 p.2 ↗ | 0360 | Size designation |
| 9-10 p.2 ↗ | -2 | Stage / variant number |
| field 1 p.2 ↗ | AADN1 | Motor / ATEX variant code (as printed in type designation 2BH20360-2AADN1-BA-Z) |
| field 2 p.2 ↗ | BA | Design / connection variant code (as printed in type designation 2BH20360-2AADN1-BA-Z) |