Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH2 2BH20360-2 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH2 0360-2: VELOCIS G-BH2 e side channel blower with integrated frequency converter (VFD). Covers 2BH20360-2AA3M6-BA, -2AA3N6-BA, -2AA3P6-BA (380 V Y, 84/85 Hz) and 400 V Δ variants, plus VFD types 2FC4152-1 to 2FC4223-1 and accessories.

Technical Data

Parameter Value Condition
Rated frequency 84 Hz p.2 ↗ 2BH20360-2AA3M6-BA, 380 V Y
Voltage 380 V p.2 ↗ 2BH20360-2AA3M6-BA, Y connection
Current 20.3 A p.2 ↗ 2BH20360-2AA3M6-BA, 380 V Y
Power 9.9 kW p.2 ↗ 2BH20360-2AA3M6-BA, 380 V Y
Max. differential pressure vacuum -450 mbar p.2 ↗ 2BH20360-2AA3M6-BA
Max. differential pressure pressure 260 mbar p.2 ↗ 2BH20360-2AA3M6-BA
Sound pressure 84 dB(A) p.2 ↗ 2BH20360-2AA3M6-BA
Weight 115 kg p.2 ↗ 2BH20360-2AA3M6-BA
Rated frequency 85 Hz p.2 ↗ 2BH20360-2AA3N6-BA, 380 V Y
Current 27.4 A p.2 ↗ 2BH20360-2AA3N6-BA, 380 V Y
Power 14.0 kW p.2 ↗ 2BH20360-2AA3N6-BA, 380 V Y
Max. differential pressure vacuum -540 mbar p.2 ↗ 2BH20360-2AA3N6-BA
Max. differential pressure pressure 520 mbar p.2 ↗ 2BH20360-2AA3N6-BA
Weight 131 kg p.2 ↗ 2BH20360-2AA3N6-BA
Rated frequency 85 Hz p.2 ↗ 2BH20360-2AA3P6-BA, 380 V Y
Current 41.0 A p.2 ↗ 2BH20360-2AA3P6-BA, 380 V Y
Power 20.5 kW p.2 ↗ 2BH20360-2AA3P6-BA, 380 V Y
Max. differential pressure vacuum -540 mbar p.2 ↗ 2BH20360-2AA3P6-BA
Max. differential pressure pressure 940 mbar p.2 ↗ 2BH20360-2AA3P6-BA
Sound pressure 85 dB(A) p.2 ↗ 2BH20360-2AA3P6-BA
Weight 156 kg p.2 ↗ 2BH20360-2AA3P6-BA
Voltage 400 V p.2 ↗ 2BH20360-2AA3M6-BA, Δ connection
Current 14.4 A p.2 ↗ 2BH20360-2AA3M6-BA, 400 V Δ
Power 7.5 kW p.2 ↗ 2BH20360-2AA3M6-BA, 400 V Δ
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH20360-2AA3M6-BA, 400 V Δ

Operating Limits

  • Max ambient temperature for performance curves: 25 °C p.1 ↗
  • Performance tolerance: ±10 % p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum pulse frequency: 4 kHz p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series / product family (side channel blower)
5-8 p.2 ↗ 0360 Size designation
9-10 p.2 ↗ -2 Stage / variant code
11-13 p.2 ↗ AA3 Motor / voltage variant code
16-17 p.2 ↗ -BA Execution / connection variant