Technical Data Sheet — G-BH2 2BH20360-3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH2 0360-3: side channel blower with integrated frequency converter (VFD), 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, IP55, UL 1450; variants with 380 V Y / 400 V Δ motor windings and VFD types A–K; order option G17 (separately driven fan), Z = U56 (EtherCAT interface).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 85 Hz p.2 ↗ | 2BH2 0360-3, 380 V Y, VFD type G |
| Voltage | 380 V p.2 ↗ | 2BH2 0360-3, Y connection |
| Current | 27.4 A p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz |
| Power | 14.0 kW p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz |
| Max. differential pressure vacuum | -570 mbar p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz |
| Max. differential pressure pressure | 350 mbar p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz |
| Sound pressure level | 76/78 dB(A) p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz (50 Hz / 60 Hz with G17) |
| Weight | 130 kg p.2 ↗ | 2BH2 0360-3, 380 V Y, VFD type G |
| Weight | 132 kg p.2 ↗ | 2BH2 0360-3, 380 V Y, VFD type G, with separately driven fan G17 |
| Current | 41.0 A p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K |
| Power | 20.5 kW p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K |
| Max. differential pressure pressure | 790 mbar p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K |
| Sound pressure level | 77/79 dB(A) p.2 ↗ | 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K |
| Weight | 173 kg p.2 ↗ | 2BH2 0360-3, 380 V Y, VFD type K |
| Weight | 175 kg p.2 ↗ | 2BH2 0360-3, 380 V Y, VFD type K, with separately driven fan G17 |
| Current | 20.4 A p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz |
| Power | 10.2 kW p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz |
| Max. differential pressure vacuum | -250 mbar p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz |
| Max. differential pressure pressure | 100 mbar p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz |
| Sound pressure level | 84 dB(A) p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz |
| Current | 26.0 A p.2 ↗ | 2BH2 0360-3, 400 V, 85 Hz |
| Power | 14.0 kW p.2 ↗ | 2BH2 0360-3, 400 V, 85 Hz |
| Max. differential pressure vacuum | -570 mbar p.2 ↗ | 2BH2 0360-3, 400 V, 85 Hz |
| Max. differential pressure pressure | 350 mbar p.2 ↗ | 2BH2 0360-3, 400 V, 85 Hz |
| Current | 39.5 A p.2 ↗ | 2BH2 0360-3, 400 V Δ, 85 Hz, VFD type J |
Operating Limits
- Max. ambient / suction temperature for performance data: 25 °C p.1 ↗
- Rated voltage / frequency set point: 345 V / 87 Hz p.1 ↗
- Minimum mains voltage for frequency converter: 380 V p.1 ↗
- Frequency converter mains voltage range: 400 V -15% … 480 V +10% p.2 ↗
- Frequency tolerance: ±6% p.2 ↗
- Protection class: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-8 p.2 ↗ | 2BH20360 | Type designation: side channel blower 2BH2, size 0360 |
| 9-10 p.2 ↗ | -3 | Version / stage code |
| 11-12 p.2 ↗ | AA | Motor / winding variant code |
| 16-17 p.2 ↗ | -BA | Design / equipment variant |
| VFD type field p.2 ↗ | A–K | Integrated frequency converter type (A 2FC4152-1 … K 2FC4223-1) |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH20360-3AA3N6-BA p.2 ↗ | 2BH20360-3AA3N6-BA | G | 380 V Y, 85 Hz, 14.0 kW, VFD type G | Weight 130 kg (132 kg with G17) |
| 2BH20360-3AA3P6-BA p.2 ↗ | 2BH20360-3AA3P6-BA | K | 380 V Y, 85 Hz, 20.5 kW, VFD type K | Weight 173 kg (175 kg with G17) |
| 2FC4152-1 p.2 ↗ | 2FC4152-1 | A | VFD type A | Rated mains 4 A, max. motor current 2 A, 3 kW, typical motor current 10 A, fuse 4 A, 2 kg |
| 2FC4752-1 p.2 ↗ | 2FC4752-1 | F | VFD type F | Rated mains 18 A, max. motor current 8 A, 15 kW, typical motor current 25 A |
| 2FC4113-1 p.2 ↗ | 2FC4113-1 | G | VFD type G | Rated mains 28 A, max. motor current 11 A, 23 kW, typical motor current 35 A |
| 2FC4153-1 p.2 ↗ | 2FC4153-1 | H | VFD type H | Rated mains 34 A, max. motor current 15 A, 28 kW, typical motor current 50 A |