Technical Data Sheet — G-BH2 2BH20540-1 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH2 0540-1: side channel blower in ATEX configuration, G-BH2 N series, ATEX categories 3GD and 3/2D as fixed-voltage machines for 50 and 60 Hz; 3/2G available only as 50 Hz or 60 Hz versions. Ordering code 2BH20540-1AADN1-BA-Z with Z=M74.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 230 ∆/ 400 Y V p.2 ↗ | 2BH20540-1, 50 Hz |
| Rated current | 22,5 ∆/ 13,1 Y A p.2 ↗ | 2BH20540-1, 50 Hz |
| Rated power | 7,5 kW p.2 ↗ | 2BH20540-1, 50 Hz |
| Max. differential pressure (vacuum) | -300 mbar p.2 ↗ | 2BH20540-1, 50 Hz |
| Max. differential pressure (pressure) | 410 mbar p.2 ↗ | 2BH20540-1, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH20540-1, 50 Hz |
| Weight | 103 kg p.2 ↗ | 2BH20540-1, 50 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH20540-1 |
| ATEX category | 3GD p.2 ↗ | 2BH20540-1 |
| Rated voltage | 460 Y V p.2 ↗ | 2BH20540-1, 60 Hz |
| Rated current | 13,0 Y A p.2 ↗ | 2BH20540-1, 60 Hz |
| Rated power | 8,6 kW p.2 ↗ | 2BH20540-1, 60 Hz |
| Max. differential pressure (vacuum) | -310 mbar p.2 ↗ | 2BH20540-1, 60 Hz |
| Max. differential pressure (pressure) | 420 mbar p.2 ↗ | 2BH20540-1, 60 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH20540-1, 60 Hz |
| Weight | 103 kg p.2 ↗ | 2BH20540-1, 60 Hz |
| Motor thermal class | F p.2 ↗ | |
| Motor efficiency class | IE3 p.2 ↗ | |
| Frequency tolerance | +/- 2 % p.2 ↗ |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Frequency tolerance: +/- 2 % p.2 ↗
- Degree of protection: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series / type: side channel blower G-BH2 N |
| 5-8 p.2 ↗ | 0540 | Size designation |
| 9-10 p.2 ↗ | -1 | Variant / stage designation |
| 11-15 p.2 ↗ | AADN1 | Motor / ATEX configuration code |
| 16-17 p.2 ↗ | -BA | Design / connection variant |
| Z= (voltage field) p.2 ↗ | D1 | Voltage variant: 230 ∆ / 400 Y, 50 Hz |
| Z= (voltage field) p.2 ↗ | D6 | Voltage variant: 400 ∆ / 690 Y, 50 Hz |
| Z= (voltage field) p.2 ↗ | D5 | Voltage variant: 500 ∆ / 575 ∆, 50 Hz |