Data sheet 2BH2 0540-1: side channel blower with integrated frequency converter (VFD), 3~ 400 V -15%…480 V +10%, 50/60 Hz ±6%, IP55, insulation class F, UL 1450 / CAN/CSA C22.2 No. 68-09. Variants differ by rated power/current and VFD type (G, A, F).

Technical Data

Parameter Value Condition
Rated frequency 50/60 Hz p.2 ↗ 2BH2 0540-1
Rated voltage 380 V p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz, Y
Rated voltage 400 V p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz, Δ
Current 20.3 A p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz, Y
Current 27.4 A p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz
Current 14.5 A p.2 ↗ 2BH20540-1AAKL6-BA, 72 Hz, Δ
Power 10.2 kW p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz
Power 14.0 kW p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz
Power 7.5 kW p.2 ↗ 2BH20540-1AAKL6-BA, 72 Hz
Max. differential pressure, vacuum -220 mbar p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz
Max. differential pressure, pressure 140 mbar p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz
Max. differential pressure, vacuum -420 mbar p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz
Max. differential pressure, pressure 330 mbar p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz
Max. differential pressure, vacuum -100 mbar p.2 ↗ 2BH20540-1AAKL6-BA, 72 Hz
Max. differential pressure, pressure 80 mbar p.2 ↗ 2BH20540-1AAKL6-BA, 72 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH20540-1AA3M6-BA, 85 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH20540-1AA3N6-BA, 85 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH20540-1AAKL6-BA, 72 Hz
Weight 91 kg p.2 ↗ 2BH20540-1AA3M6-BA
Weight 123 kg p.2 ↗ 2BH20540-1AA3N6-BA
Weight 83 kg p.2 ↗ 2BH20540-1AAKL6-BA
Protection class IP55 p.2 ↗ integrated VFD
Insulation material class F p.2 ↗ motor
Rated voltage/frequency set point 345 V / 87 Hz p.1 ↗ delta connection of motor
Minimum pulse frequency 4 kHz p.1 ↗ frequency converter operation

Operating Limits

  • Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Mains voltage for frequency converter: 380 V minimum p.1 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ 2BH20540 Type/size designation (side channel blower 2BH2, size 0540)
10-12 p.2 ↗ 1AA Motor/design variant field
17-18 p.2 ↗ BA Suffix variant field

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH20540-1AA3M6-BA p.2 ↗ 2BH20540-1AA3M6-BA G 85 Hz, 380 V Y, 20.3 A, 10.2 kW VFD type G
2BH20540-1AA3N6-BA p.2 ↗ 2BH20540-1AA3N6-BA G 85 Hz, 380 V, 27.4 A, 14.0 kW VFD type G
2BH20540-1AAKL6-BA p.2 ↗ 2BH20540-1AAKL6-BA F 72 Hz, 330 V Δ, 14.5 A, 7.5 kW VFD type F
2BH20540-1AAKM6-BA p.2 ↗ 2BH20540-1AAKM6-BA G 85 Hz, 400 V Δ, 20.4 A, 10.2 kW VFD type G
2BH20540-1AAKN6-BA p.2 ↗ 2BH20540-1AAKN6-BA G 85 Hz, 400 V Δ, 26.0 A, 14.0 kW VFD type G