Technical Data Sheet — G-BH2 2BH20780-1 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH2 0780-1: side channel blower in ATEX configuration (G-BH2 N), 50 Hz and 60 Hz, ATEX categories 3GD and 3/2D (fixed voltage machines), 3/2G 50 Hz or 60 Hz versions.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 230 ∆/ 400 Y V p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Rated current | 35,0 ∆/ 20,0 Y A p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Power | 11,0 kW p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Max. vacuum | -300 mbar p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Max. differential pressure | 420 mbar p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Sound pressure level | 71 dB(A) p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Weight | 150 kg p.2 ↗ | 2BH2 0780-1, 50 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH2 0780-1 |
| ATEX category | 3GD p.2 ↗ | 2BH2 0780-1 |
| Rated voltage | 460 Y V p.2 ↗ | 2BH2 0780-1, 60 Hz |
| Rated current | 19,5 Y A p.2 ↗ | 2BH2 0780-1, 60 Hz |
| Power | 12,6 kW p.2 ↗ | 2BH2 0780-1, 60 Hz |
| Max. vacuum | -310 mbar p.2 ↗ | 2BH2 0780-1, 60 Hz |
| Max. differential pressure | 380 mbar p.2 ↗ | 2BH2 0780-1, 60 Hz |
| Sound pressure level | 76 dB(A) p.2 ↗ | 2BH2 0780-1, 60 Hz |
Operating Limits
- Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Sound pressure level tolerance: ±3 dB(A) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Type series (side channel blower) |
| 5-8 p.2 ↗ | 0780 | Size |
| 9-10 p.2 ↗ | -1 | Variant |
| field 1 p.2 ↗ | AADP1 | ATEX motor variant |
| field 2 p.2 ↗ | BA | Configuration code |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH20780-1AADP1-BA-Z Z=M74 p.2 ↗ | 2BH20780-1AADP1-BA-Z Z=M74 | M74 | ATEX category 3GD, 50 Hz: 230 ∆/400 Y; 60 Hz: 460 Y |