Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH2 2BH20780-2 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH2 0780-2: VELOCIS G-BH2 e side channel blower with integrated frequency converter (VFD), 2BH20780-2 series; covers 50 Hz and 60 Hz operation, Δ/Υ motor connection, VFD types 2FC4xxx-1 and order options Z=U51…U54.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH20780-2, 50 Hz
Rated voltage 380 V p.2 ↗ 2BH20780-2, 50 Hz, Υ connection
Rated current 48.0 A p.2 ↗ 2BH20780-2, 50 Hz, Υ connection
Motor power 25.0 kW p.2 ↗ 2BH20780-2, 50 Hz
Max. differential pressure, vacuum -400 mbar p.2 ↗ 2BH20780-2, 50 Hz
Max. differential pressure, pressure 160 mbar p.2 ↗ 2BH20780-2, 50 Hz
Sound pressure level 79/80 dB(A) p.2 ↗ 2BH20780-2, 50 Hz
Weight 225 kg p.2 ↗ 2BH20780-2, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH20780-2, 60 Hz
Rated voltage 400 V p.2 ↗ 2BH20780-2, 60 Hz, Δ connection
Rated current 53.7 A p.2 ↗ 2BH20780-2, 60 Hz, Δ connection
Motor power 28.2 kW p.2 ↗ 2BH20780-2, 60 Hz
Max. differential pressure, vacuum -480 mbar p.2 ↗ 2BH20780-2, 60 Hz
Max. differential pressure, pressure 270 mbar p.2 ↗ 2BH20780-2, 60 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH20780-2, 60 Hz
Weight 227 kg p.2 ↗ 2BH20780-2, 60 Hz
Rated voltage/frequency set point 345 V / 87 Hz p.1 ↗ frequency converter operation, delta connection
Minimum pulse frequency 4 kHz p.1 ↗ frequency converter operation
Minimum mains voltage for frequency converter 380 V p.1 ↗ frequency converter operation
Max. suction and ambient temperature for stated pressure differences 25 °C p.1 ↗ performance curves
Performance curve tolerance ± 10 % p.1 ↗ air at 15 °C, 1013 mbar

Operating Limits

  • Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series: side channel blower G-BH2 e
5-8 p.2 ↗ 0780 Size
9-10 p.2 ↗ -2 Stage/variant code
11-12 p.2 ↗ AA Motor/connection variant (Υ for 50 Hz, Δ for 60 Hz)
16-17 p.2 ↗ -BA Version suffix