Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH2 2BH20780-3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH2 0780-3: VELOCIS G-BH2 e side channel blower for operation on frequency converter; covers 50 Hz, 60 Hz and 87 Hz (345 V, delta) operation, plus integrated frequency converter (IP55) variants A–K and I/O automation options Z=U51…U54.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH2 0780-3
Rated frequency 60 Hz p.2 ↗ 2BH2 0780-3
Rated frequency 85 Hz p.2 ↗ 2BH2 0780-3, 400 V
Rated voltage 400 V p.2 ↗ 2BH2 0780-3, 85 Hz
Current 75.0 A p.2 ↗ 2BH2 0780-3, 85 Hz, 400 V
Power 40.0 kW p.2 ↗ 2BH2 0780-3, 85 Hz, 400 V
Max. differential pressure vacuum -600 mbar p.2 ↗ 2BH2 0780-3, 50 Hz
Max. differential pressure vacuum -580 mbar p.2 ↗ 2BH2 0780-3, 60 Hz
Max. differential pressure vacuum -500 mbar p.2 ↗ 2BH2 0780-3, 85 Hz, 400 V
Max. differential pressure pressure 980 mbar p.2 ↗ 2BH2 0780-3, 50 Hz
Max. differential pressure pressure 820 mbar p.2 ↗ 2BH2 0780-3, 60 Hz
Max. differential pressure pressure 450 mbar p.2 ↗ 2BH2 0780-3, 85 Hz, 400 V
Sound pressure level 71 dB(A) p.2 ↗ 2BH2 0780-3, 50 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH2 0780-3, 60 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH2 0780-3, 85 Hz, 400 V
Weight 256 kg p.2 ↗ 2BH2 0780-3
Rated voltage/frequency set point 345 V / 87 Hz p.1 ↗ frequency converter operation, delta connection
Minimum pulse frequency 4 kHz p.1 ↗ frequency converter operation
Minimum mains voltage 380 V p.1 ↗ frequency converter operation
Rated mains voltage 400V (-15%) … 480V (+10%) V p.2 ↗ integrated frequency converter
Protection class IP55 p.2 ↗ integrated frequency converter motor

Operating Limits

  • Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗
  • Minimum pulse frequency (frequency converter operation): 4 kHz p.1 ↗
  • Minimum mains voltage (frequency converter operation): 380 V p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series / type: side channel blower G-BH2 e
5-8 p.2 ↗ 0780 Size designation
9-10 p.2 ↗ -3 Variant / stage code
field 1 p.2 ↗ A Motor / voltage variant (A = 400 V, 85 Hz data)
field 2 p.2 ↗ A Connection / winding variant
field 3 p.2 ↗ 3 Frequency / speed variant
field 4 p.2 ↗ Q Option field
field 5 p.2 ↗ 6 Option field
field 6 p.2 ↗ B Option field
field 7 p.2 ↗ A Option field