Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV2 2BV2070 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Liquid ring vacuum pump family L-BV2, data sheet 2BV2 070. Covers 2BV2070 with 50 Hz and 60 Hz motors, voltage ranges 190-210, 220-240/380-420, 440-480, 500, 575, 380-420/660-725, 460 V, IE3 or NP efficiency, and material variants N (cast iron/ceramic/bronze), C (cast iron/ceramic/CrNi steel), P (CrNi steel/ceramic/CrNi steel), H (CrNi steel/CrNi steel/CrNi steel). ATEX category 2G pumps available.

Technical Data

Parameter Value Condition
Operating principle Liquid ring vacuum pump p.1 ↗ 2BV2 070
Ultimate inlet pressure 33 mbar abs. p.1 ↗ 2BV2 070
Cavitation-free operation down to 80 mbar abs. p.1 ↗ 2BV2 070, with built-in cavitation protection
Suction capacity 66 m³/h p.2 ↗ 2BV2070, 50 Hz, 2.6 kW
Suction capacity 70 m³/h p.2 ↗ 2BV2070, 50 Hz, 3.7 kW
Suction capacity 70 m³/h p.2 ↗ 2BV2070, 60 Hz, 3.5 kW
Motor power 2,6 kW p.2 ↗ 2BV2070, 50 Hz
Motor power 3,7 kW p.2 ↗ 2BV2070, 50 Hz
Motor power 3,5 kW p.2 ↗ 2BV2070, 60 Hz
Voltage 190-210 V p.2 ↗ 2BV2070, 50 Hz, 2.6 kW
Voltage 220-240 / 380-420 V p.2 ↗ 2BV2070, 50 Hz, 2.6 kW
Voltage 440-480 V p.2 ↗ 2BV2070, 60 Hz, 3.7 kW
Current 16,5 A p.2 ↗ 2BV2070, 50 Hz, 190-210 V, 2.6 kW
Current 18,6 / 9,3 A p.2 ↗ 2BV2070, 50 Hz, 190-210/380-420 V, 3.7 kW
Current 8,1 A p.2 ↗ 2BV2070, 60 Hz, 440-480 V, 3.7 kW
Service factor 1,54 p.2 ↗ 2BV2070, 50 Hz, 2.6 kW
Service factor 1,23 p.2 ↗ 2BV2070, 50 Hz, 3.7 kW
Service factor 1,22 p.2 ↗ 2BV2070, 60 Hz, 3.5 kW
Efficiency level IE3 p.2 ↗ 2BV2070, 2.6 kW and 3.7 kW
Noise level 66 dB(A) p.2 ↗ 2BV2070, 50 Hz, 2.6 kW
Noise level 70 dB(A) p.2 ↗ 2BV2070, 50 Hz, 3.7 kW
Weight 46 kg p.2 ↗ 2BV2070, 2.6 kW
Weight 49 kg p.2 ↗ 2BV2070, 3.7 kW
Protection rating IP55 p.2 ↗ 2BV2070
Insulation class F p.2 ↗ 2BV2070

Operating Limits

  • Minimum inlet pressure (ultimate vacuum): 33 mbar abs. p.1 ↗
  • Cavitation-free operation minimum inlet pressure: 80 mbar abs. p.1 ↗
  • Maximum additional water carry-over: 0,70 m³/h at 50 Hz; 0,85 m³/h at 60 Hz p.2 ↗
  • Maximum back pressure: 1200 mbar abs. p.2 ↗
  • Protection rating: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BV2 Product family: liquid ring vacuum pump L-BV2
5-7 p.2 ↗ 070 Size 070
field 1 (after 2BV2…-) p.2 ↗ 0 Design variant / generation
field 2 (material code) p.2 ↗ N, C, P, H Material variant: N = cast iron casing with ceramic coating / bronze port plate; C = cast iron casing with ceramic coating / CrNi steel port plate; P = CrNi steel casing / ceramic port plate / CrNi steel impeller; H = CrNi steel casing / Cr
field 3 (voltage/frequency code) p.2 ↗ K, Q Voltage/frequency variant: K = 50 Hz 190-210 V or 220-240/380-420 V; Q = 60 Hz 440-480 V or 50 Hz 380-420/660-725 V
field 4 (suffix) p.2 ↗ 1, 6, 7 Ordering suffix: 1 = 2.6 kW variant; 6 = 3.7 kW variant; 7 = 3.7 kW variant with 60 Hz 440-480 V