Elmo Rietschle 2BV2060
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV2060

Elmo Rietschle 2BV2060 — Liquid Ring Vacuum Pumps with Max inlet pressure 101.3 kPa, Motor power 3.5 kW, Ultimate pressure 10 mbar.

Single-stage liquid-ring vacuum pump 2BV2060 with cast-iron casing, ceramic coating and bronze impeller, driven by a 3.05 kW (50 Hz) / 3.5 kW (60 Hz) motor. Ultimate pressure 10 mbar, max inlet 1013 mbar, design operating-liquid flow 0.20 m³/h. Used for wet, condensable or particle-laden gas duty where a dry pump would foul.

Max inlet pressure
101.3 kPa
Motor power
3.5 kW
Ultimate pressure
10 mbar

Elmo Rietschle L-BV2 Series — Model Comparison & Selection

Model Motor power, kWOperating principlePumping speed, m³/hNoise level, dBPower supplyWeight, kg
2BV2060 Current 3.5Liquid ring vacuum pump—653~ 50/60 Hz28
2BV2061 3Liquid ring2765AC26
2BV2070 7.3Liquid ring7070AC49
2BV2071 7.3Liquid ring50061AC64

Full specifications

Core Performance & Functional Specifications
Max inlet pressure 1013 mbar
Motor power 3.05 kW (50 Hz)
60 Hz: 3.5 kW
Operating principle Liquid ring vacuum pump
Ultimate pressure 10 mbar
Dimensions, Weight & Mechanical Design
Number of stages 1 dimensionless
Weight 28 kg
Electrical, Power & Drive Specifications
Power supply 3~ 50/60 Hz
Operating Conditions, Environment & Protection
Noise level 62 dB(A) (50 Hz)
60 Hz: 65 dB(A)
Protection rating IP55

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Process Limits
Keep suction pressure 50 mbar above vapour pressure

Operating below the vapour pressure of the operating liquid causes cavitation, erosion and loss of vacuum. If the process vapour pressure approaches the suction pressure, consult the manufacturer before commissioning.

ATEX Operating Instructions, Section 3.3
Process Limits
Limit water carry-over to 2.5× design flow continuous

The inlet can tolerate 2.5 times the 0.20 m³/h design operating-liquid flow continuously, or 7× for no more than 2 seconds. Exceeding this requires a liquid separator upstream to protect the pump.

Technical Data, page 13
Mounting
Maintain 34 mm clearance around fan guard

Insufficient clearance restricts cooling air and causes motor overheating. The 34 mm minimum applies to 2BV2060/2061 types and must be checked after installation of guards or enclosures.

Technical Data, page 8
Mounting
Do not exceed 100 Nm on suction/discharge connections

Over-tightening piping can crack the cast-iron flanges or damage the ceramic coating. Use torque wrenches and support heavy pipework independently of the pump.

Installation, page 16
Electrical
Verify motor insulation resistance before first start

Dry windings if insulation resistance is ≤1 kΩ per volt of measurement potential. Commissioning with damp windings risks motor failure and invalidates warranty.

Commissioning, page 20
Electrical
VFD operation limited to 4612 min⁻¹ for 2BV2060

When using a frequency converter, do not exceed the maximum speed of 4612 min⁻¹. ATEX variants of this model must not be operated with a frequency converter at all.

Technical Data, page 9; ATEX Instructions, Section 5.3.2
Maintenance
Re-grease or replace bearings at 20,000 h

Bearing service interval is 2.5 years or 20,000 operating hours. Use UNIREX N3 grease (DIN 51825-K3N), filling approx. 50% of roller-bearing free space and 65% of adjacent areas. Do not mix grease types.

Maintenance, page 28
Maintenance
Fit intake strainer for first 100 operating hours

Installation debris can damage the impeller and casing. Fit a temporary strainer in the suction line and remove it after the first 100 hours of operation.

Installation, page 16

Selection & Integration Q&A

When should I choose 2BV2060 instead of 2BV2061 or 2BV2070?

Pick 2BV2060 for low-flow duties needing 10 mbar ultimate with a 3.05 kW motor (50 Hz) or 3.5 kW (60 Hz).

What are the requirements for the operating-liquid supply system?

Provide 0.20 m³/h design flow with first fill of 0.5 L. Keep liquid temperature +5 to +80 °C (nominal +15 °C).

What maintenance parts and intervals are required, and what is not included?

Bearings need service every 2.5 years or 20,000 h with UNIREX N3 grease; intake strainer for first 100 h is not supplied. Operating liquid, piping, and electrical cables are not included in base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Technical Data Sheet — L-BV2 2BV2060 IE3 vacuum pump (EN)
Datasheet ·391,0 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF