Technical Data Sheet — L-BV5 2BV5131 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BV5 131, Edition 04/2015: liquid ring vacuum pump with ejector, model range L-BV5. Motors standard for 50 and 60 Hz input voltage ranges, protection category IP55, approbated for UL and CSA. Vacuum ATEX-pumps for category 2G (2006/42 EG) available.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | L-BV5, 97 % vacuum |
| Cavitation-free operation down to | 80 mbar abs. p.1 ↗ | L-BV5, with built-in cavitation protection |
| Suction capacity | see characteristic curve (up to 500) m³/h p.1 ↗ | L-BV5, 50 Hz |
| Suction capacity | see characteristic curve (up to 500) m³/h p.1 ↗ | L-BV5, 60 Hz |
| Power consumption at pump shaft | see characteristic curve (up to 16) kW p.1 ↗ | L-BV5, 50 Hz |
| Power consumption at pump shaft | see characteristic curve (up to 16) kW p.1 ↗ | L-BV5, 60 Hz |
| Protection rating | IP55 p.1 ↗ | standard motor |
| Intake temperature for characteristic curves | 20 °C p.1 ↗ | 100 % saturated air |
| Operating liquid temperature for characteristic curves | 15 °C p.1 ↗ | water as operating liquid, suction pressure 1013 mbar abs. |
| Characteristic curve tolerance | ± 10 % p.1 ↗ |
Operating Limits
- minimum inlet pressure: 33 mbar abs. (97 % vacuum) p.1 ↗
- cavitation-free operation minimum inlet pressure: 80 mbar abs. p.1 ↗
- protection category: IP55 p.1 ↗