Elmo Rietschle 2BV5161
Elmo Rietschle 2BV5161 — Liquid Ring Vacuum Pumps with Motor power 15 kW, Pumping speed 500 m³/h.
The 2BV5161 is a liquid-ring vacuum pump/compressor in the L-BV5 series, size 161, with a 15 kW motor and 500 m³/h pumping speed at 50 Hz. It is the largest standard variant in the series, distinguished by an 8 L first-fill operating-liquid volume and 80 mm minimum heat-dissipation clearance. It serves as the central vacuum source in systems requiring reliable, oil-free extraction of gases and vapours.
Elmo Rietschle L-BV5 Series — Model Comparison & Selection
| Model | Motor power, kW | Operating principle | Noise level, dB | Power supply | Pumping speed, m³/h | Weight, kg |
|---|---|---|---|---|---|---|
| 2BV5161 Current | 15 | Liquid ring | 74 | AC | 500 | 160 |
| 2BV5110 | 5.5 | ring blow | 67 | AC | — | 67 |
| 2BV5111 | 7.5 | Liquid ring | 72 | 3~ AC | — | 124 |
| 2BV5121 | 11 | Liquid ring compressor | 70 | AC | 40 | — |
| 2BV5131 | 15 | Liquid ring | 74 | AC | 17.4 | 178 |
| L-BV5 2060 | — | — | — | — | — | — |
Full specifications
| Motor power | 15.0 kW (50 Hz) 60 Hz: 15.0 kW |
| Operating principle | Liquid ring |
| Pumping speed | 500 m³/h (50 Hz) 60 Hz: 575 m³/h |
| Rotational speed | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Suction capacity (alt 60 Hz) mfr | 660-725 m3/h (60 Hz) |
| Weight | 160 kg |
| Weight approx. (alt var) mfr | 162 kg |
| Power supply | AC |
| Rated motor power (alt 60 Hz) mfr | 17.7 kW (60 Hz) |
| Noise level | 74 dB(A) |
| Operating temperature | Water (pH 6-9) |
| Protection rating | IP55 |
| Sound pressure level (alt var) mfr | 75 dB(A) |
Description
Construction and series positioning
- The 2BV5161 is a single-stage liquid-ring machine with a cast-iron casing and bronze or CrNi steel impeller (variants K, C, H).
- Within the L-BV5 series, it is the highest-capacity standard model: 15 kW motor, 500 m³/h at 50 Hz and 575 m³/h at 60 Hz, compared to 5.5–15 kW and lower flows of siblings 2BV5110 through 2BV5131.
- It shares the series' IP55 motor, insulation class F, and optional ATEX category 2G construction (variant -..D..-Z or -..G..-Z).
Behavior under load and media
- The operating liquid (typically water, pH 6–9) forms the sealing ring; first fill is 8.0 L, and the design operating-liquid flow must be maintained to achieve the stated suction capacity.
- Maximum gas/vapour temperature is +80 °C; above this, increase operating-liquid flow to 2× design flow or install a pre-condenser.
- Maximum discharge pressure in vacuum operation is 1.3 bar abs; maximum internal pressure is 8 bar abs.
- Maximum water carry-over through the inlet is 2.5× design flow continuously and 5× for max 2 s.
- Minimum suction pressure must remain at least 50 mbar above the vapour pressure of the operating fluid to avoid cavitation.
Installation, connection and control
- The motor is directly connected to the AC supply; operation with a frequency converter is permitted only in non-ATEX versions, with a speed range of 913–1597 min⁻¹ for the 2BV5161.
- Electrical supply tolerance is ±5% voltage and ±2% frequency deviation.
- Piping connections to suction and discharge must not exceed 100 Nm tightening torque.
- For ATEX versions, compulsory monitoring includes discharge pressure (G2), operating-liquid feed (F1, trip at ≤50% design flow), liquid level (hf 175–235 mm), and operating-liquid temperature (trip at ≥60 °C).
- Bleeder resistance to ground must be <10⁶ Ω for the unit and each attached accessory.
Integration & Operating Notes
The 2BV5161 requires a minimum clearance of 80 mm for heat dissipation; insufficient clearance can cause overheating and reduced motor life. Ensure the installation location allows unobstructed airflow and consider ambient temperature limits of +5 °C to +40 °C.
Operating below this margin risks cavitation, which can damage the impeller and reduce performance. For ATEX versions, this is mandatory; for standard versions, it is a design guideline. Monitor suction pressure and ensure the operating liquid temperature (max +80 °C) is controlled.
For ATEX category 2G units, liquid feed, liquid level, and discharge pressure monitoring must be functionally independent and must shut down the unit on fault. Do not share a single controller path; EN ISO 13849 implementation is recommended. Non-ATEX units have no such requirement.
Bearing maintenance interval is 2.5 years or 20,000 operating hours for standard versions; ATEX versions require service every 2 years or 18,000 hours by a service technician. Use UNIREX N3 grease or equivalent, filling 50% of bearing free space. Weekly dust removal is required for ATEX.
Over-tightening suction and discharge connections can crack the casing or damage threads. Use a torque wrench and follow the specified limit. Also, install a suction strainer for the first 100 operating hours to prevent debris ingress.
Dry windings if insulation resistance is ≤1 MΩ per volt of measurement potential. This prevents motor failure due to moisture. Also ensure terminal box wiring maintains a minimum air gap of 5.5 mm between non-insulated energized components and to earth.
Selection & Integration Q&A
Choose 2BV5161 for the highest flow in the series (500 m³/h at 50 Hz) and 15 kW motor. Siblings 2BV5131 and 2BV5121 offer lower flows and are suited for smaller duties. The 2BV5161 also has a larger first-fill volume (8 L) and requires more space for heat dissipation.
The operating liquid (water, pH 6–9) must be supplied at a design flow rate (refer to technical data) and with a maximum operating-liquid temperature of +80 °C. For ATEX versions, flow monitoring must trip at ≤50% of design flow, and liquid level must be maintained between 175 and 235 mm. A pressure-resistant separator is required on the suction side if used.
The standard ambient temperature range is +5 °C to +40 °C, and maximum installation altitude is 1000 m above sea level. For outdoor installation, provide protection against weather and ensure the IP55 rating is sufficient. Consult the manufacturer for altitudes above 1000 m.
The base delivery does not include operating liquid, suction strainer (recommended for first 100 hours), or monitoring sensors for ATEX. Grease for bearings (UNIREX N3) must be procured separately. For ATEX, accessories like separators and check valves must have bleeder resistance <10⁶ Ω and be assessed for the hazardous area.