Elmo Rietschle 2BV5111
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV5111

Elmo Rietschle 2BV5111 — Liquid Ring Vacuum Pumps with Motor power 8.6 kW.

The 2BV5111 is a liquid-ring vacuum pump/compressor in the L-BV5 series, driven by a 7.5 kW (50 Hz) / 8.6 kW (60 Hz) three-phase motor with IP55 protection. It is distinguished from smaller siblings by its 7.5 kW rating and from larger ones by its 3.0 L first-fill and 130/170 mm liquid-level window. It serves as a robust vacuum source for systems handling wet or condensable gas streams.

Motor power
8.6 kW

Elmo Rietschle L-BV5 Series — Model Comparison & Selection

Model Motor power, kWOperating principleNoise level, dBPower supplyPumping speed, m³/hWeight, kg
2BV5111 Current 7.5Liquid ring723~ AC—124
2BV5110 5.5ring blow67AC—67
2BV5121 11Liquid ring compressor70AC40—
2BV5131 15Liquid ring74AC17.4178
2BV5161 15Liquid ring74AC500160
L-BV5 2060 ——————

Full specifications

Core Performance & Functional Specifications
Motor power 7.5 kW (50 Hz)
60 Hz: 8.6 kW
Operating principle Liquid ring
Rotational speed 1.00 rpm (50 Hz)
60 Hz: 1.32 rpm
Dimensions, Weight & Mechanical Design
Weight 124 kg
Electrical, Power & Drive Specifications
Power supply 3~ AC (50/60 Hz)
Operating Conditions, Environment & Protection
Noise level 72 dB
Protection rating IP55

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Process Limits
Do not exceed 1.3 bar abs discharge pressure in vacuum duty

Exceeding the maximum discharge pressure of 1.3 bar abs (for 2BV5.. types) when the design operating-liquid flow is maintained can overload the pump and damage internal components. Install pressure relief or monitoring on the discharge line.

Operating Instructions — L-BV2, Technical data, page 10
Process Limits
Maintain suction pressure at least 50 mbar above vapour pressure

Operating below this margin causes cavitation, which erodes the impeller and reduces performance. If the process vapour pressure is close to the suction pressure, consult the manufacturer for a suitable configuration.

Operating Instructions — L-BV2 ATEX, Concerning 3.3 / p.5
Mounting
Keep vibration velocity below 4.5 mm/s at the measuring points

Excessive vibration from piping misalignment or foundation issues can lead to bearing failure and seal damage. Measure vibration at the points shown in Fig. 7 of the manual after installation and during operation.

Operating Instructions — L-BV2, Installation, page 15
Electrical
Verify motor insulation resistance before first start

If the insulation resistance is ≤1 kΩ per volt of measurement potential, the windings must be dried. Starting with low insulation resistance risks motor failure and electrical shock.

Operating Instructions — L-BV2, Commissioning, page 20
Maintenance
Re-grease or replace bearings every 2.5 years or 20,000 hours

Use UNIREX N3 grease or equivalent per DIN 51825-K3N, filling approximately 50% of the free space in roller bearings and 65% of adjacent areas. For ATEX units, the interval is 2 years or 18,000 hours and must be performed by a service technician.

Operating Instructions — L-BV2, Maintenance, page 28; ATEX supplement, Concerning 9.1 / p.8
Maintenance
Fit an intake strainer for the first 100 operating hours

This prevents installation residues and debris from entering the pump during initial running-in. After 100 hours, the strainer should be removed or cleaned as appropriate.

Operating Instructions — L-BV2, Installation, page 16

Selection & Integration Q&A

When should I choose the 2BV5111 over the 2BV5110 or 2BV5121?

Choose the 2BV5111 when your vacuum demand requires a 7.5 kW motor at 50 Hz, offering more capacity than the 5.5 kW 2BV5110 but less than the 11 kW 2BV5121. The 2BV5121 is also available as a liquid-ring compressor, so select it if you need compressing duty; the 2BV5111 is primarily a vacuum pump.

What are the requirements for the suction and discharge piping connected to the 2BV5111?

Piping must be aligned without stress, and tightening torque at the suction and discharge connections must not exceed 100 Nm. Use appropriate gaskets and ensure the pipes are supported independently to avoid transferring loads to the pump casing.

Can I install the 2BV5111 outdoors or in a high-altitude location?

The standard ambient temperature range is +5 °C to +40 °C, and the maximum installation altitude is 1000 m above sea level. For outdoor installation, provide protection against weather and ensure the IP55 motor is suitable; for altitudes above 1000 m, consult the manufacturer for derating.

What maintenance items and accessories are not included with the base pump?

The base delivery does not include the operating-liquid separator, intake strainer, or monitoring sensors (flow, level, pressure) required for ATEX or automatic operation. Bearings require periodic greasing with UNIREX N3, and a spare parts kit including seals and gaskets is recommended for service.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BV5 2BV5111 IE3 compressor (EN)
Datasheet ·428,7 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF