Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated voltage | 230 ∆/ 400 Y V p.2 ↗ | 2BH20360-1, 50 Hz |
| Rated current | 17,2 ∆/ 9,9 Y A p.2 ↗ | 2BH20360-1, 50 Hz |
| Power | 5,5 kW p.2 ↗ | 2BH20360-1, 50 Hz |
| Max. vacuum | -280 mbar p.2 ↗ | 2BH20360-1, 50 Hz |
| Max. differential pressure | 370 mbar p.2 ↗ | 2BH20360-1, 50 Hz |
| Sound level | 71 dB(A) p.2 ↗ | 2BH20360-1, 50 Hz |
| Weight | 56 kg p.2 ↗ | 2BH20360-1, 50 Hz |
| Degree of protection | IP55 p.2 ↗ | 2BH20360-1 |
| Rated voltage | 460 Y V p.2 ↗ | 2BH20360-1, 60 Hz |
| Rated current | 9,7 Y A p.2 ↗ | 2BH20360-1, 60 Hz |
| Power | 6,3 kW p.2 ↗ | 2BH20360-1, 60 Hz |
| Max. vacuum | -300 mbar p.2 ↗ | 2BH20360-1, 60 Hz |
| Max. differential pressure | 410 mbar p.2 ↗ | 2BH20360-1, 60 Hz |
| Sound level | 76 dB(A) p.2 ↗ | 2BH20360-1, 60 Hz |
| Weight | 56 kg p.2 ↗ | 2BH20360-1, 60 Hz |
Operating Limits
- Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Frequency tolerance: +/- 2 % p.2 ↗
- Degree of protection: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series G-BH2 side channel blower |
| 5-8 p.2 ↗ | 0360 | Size 0360 |
| 9-10 p.2 ↗ | -1 | Variant 1 |
| field 1 p.2 ↗ | AADM1 | ATEX motor/equipment variant code |
| field 2 p.2 ↗ | BA | Further equipment variant code |