Technical Data Sheet — L-BV5 2BV5121 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BV5 121, liquid ring vacuum pump, model range L-BV5. Variants: cast iron (K) and stainless steel (H) material versions, with port plate/impeller variants K, C, H; 3~ 50/60 Hz motors, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09; ATEX category 2G vacuum pumps available.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | L-BV5 family, 97 % vacuum |
| Cavitation-free operation down to | 80 mbar abs. p.1 ↗ | built-in cavitation protection |
| Rated voltage | 190-210 V p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz, delta |
| Rated voltage | 380-420 V p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz, star |
| Rated current | 45,0 A p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz, 190-210 V delta |
| Rated current | 22,6 A p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz, 380-420 V star |
| Motor power | 7,0 kW p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz |
| Motor power | 9,7 kW p.2 ↗ | 2BV5121-0 K03-1B, 60 Hz |
| Service factor | 1,57 - p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz |
| Service factor | 1,13 - p.2 ↗ | 2BV5121-0 K03-1B, 60 Hz |
| Efficiency class | IE3 - p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz |
| Quantity of operating liquid | 70 m3/h p.2 ↗ | 2BV5121-0 K03-1B, 50 Hz |
| Quantity of operating liquid | 75 m3/h p.2 ↗ | 2BV5121-0 K03-1B, 60 Hz |
| Sound pressure level | 152 dB(A) p.2 ↗ | 2BV5121-0 K03-1B, cast iron version (*) |
| Sound pressure level | 156 dB(A) p.2 ↗ | 2BV5121-0 K03-1B, stainless steel version (**) |
| Weight | 152 kg p.2 ↗ | 2BV5121-0 K03-1B, cast iron version (*) |
| Weight | 156 kg p.2 ↗ | 2BV5121-0 K03-1B, stainless steel version (**) |
| Protection rating | IP55 - p.1 ↗ | standard motor |
| Insulation material class | F - p.2 ↗ | standard motor |
| Max. additional water carry-over | 3,00 m³/h p.2 ↗ | 50 Hz |
| Max. additional water carry-over | 3,75 m³/h p.2 ↗ | 60 Hz |
| Max. back pressure | 1300 mbar abs. p.2 ↗ | 50 Hz and 60 Hz |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs. p.1 ↗
- Cavitation-free operation minimum inlet pressure: 80 mbar abs. p.1 ↗
- Max. additional water carry-over at 50 Hz: 3,00 m³/h p.2 ↗
- Max. additional water carry-over at 60 Hz: 3,75 m³/h p.2 ↗
- Max. back pressure: 1300 mbar abs. p.2 ↗
- Protection rating: IP55 p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BV5 | Product family: liquid ring vacuum pump |
| 5-7 p.2 ↗ | 121 | Size designation (2BV5 121) |
| field after 2BV5 p.3 ↗ | K / C / H | Material version: K = cast iron housing/port plate with bronze impeller; C = cast iron housing/port plate with CrNi steel impeller; H = CrNi steel housing/port plate/impeller |
| voltage field p.2 ↗ | 1 | Voltage code: 190-210 Δ / 380-420 Y (50 Hz); 200 YY / 230 Δ / 400 Y (60 Hz) |
| voltage field p.2 ↗ | 6 | Voltage code: 220-240 Δ / 380-420 Y (50 Hz); 220-240 YY / 440-480 Y (60 Hz) |
| voltage field p.2 ↗ | 7 | Voltage code: 380-420 Δ / 660-725 Y (50 Hz); 440-480 Δ (60 Hz) |
| voltage field p.2 ↗ | 5 | Voltage code: 475-525 Δ / 550-600 Y (50 Hz); 475-525 Δ / 550-600 Y (60 Hz) |
| voltage field p.2 ↗ | Q | Voltage code: 400 Δ / 690 Y (50 Hz); 460 Δ (60 Hz) |