| Ultimate inlet pressure |
33 mbar abs.
p.1 ↗ |
97 % vacuum |
| Cavitation-free operation down to |
80 mbar abs.
p.1 ↗ |
|
| Frequency |
50 Hz
p.2 ↗ |
2BV5131, 400 D / 690 Y |
| Voltage |
400 D / 690 Y V
p.2 ↗ |
2BV5131, 50 Hz |
| Current |
26,0 D / 15,1 Y A
p.2 ↗ |
2BV5131, 50 Hz, 400 D / 690 Y |
| Motor power |
14,1 hp
p.2 ↗ |
2BV5131, 50 Hz |
| Service factor |
1,29
p.2 ↗ |
2BV5131, 50 Hz |
| Efficiency class |
IE3
p.2 ↗ |
2BV5131, 50 Hz |
| Quantity of operating liquid |
1,1 m³/h
p.2 ↗ |
2BV5131, 50 Hz |
| Sound pressure level |
73 dB(A)
p.2 ↗ |
2BV5131, 50 Hz |
| Weight |
476* / 483** lbs
p.2 ↗ |
2BV5131, 50 Hz; * material K, ** material H |
| Frequency |
50 Hz
p.2 ↗ |
2BV5131, 500 D |
| Voltage |
500 D V
p.2 ↗ |
2BV5131, 50 Hz |
| Current |
21,0 D A
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Motor power |
14,1 hp
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Service factor |
1,29
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Efficiency class |
IE3
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Quantity of operating liquid |
1,1 m³/h
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Sound pressure level |
73 dB(A)
p.2 ↗ |
2BV5131, 50 Hz, 500 D |
| Weight |
476* / 483** lbs
p.2 ↗ |
2BV5131, 50 Hz, 500 D; * material K, ** material H |
| Protection rating |
IP55
p.2 ↗ |
ATEX 3~ 50 Hz version |
| Insulation material class |
F
p.2 ↗ |
ATEX 3~ 50 Hz version |
| ATEX category |
II 2G Ex h IIB T3 Gb
p.2 ↗ |
material K (cast iron); motor: 0158 II 2G Ex eb IIC T3 Gb |
| ATEX category |
II 2G Ex h IIC T3 Gb
p.2 ↗ |
material H (stainless steel); motor: 0158 II 2G Ex eb IIC T3 Gb |