Technical Reference Summary
Covered Models & Document Scope
L-BV5 liquid ring vacuum pump with ejector, data sheet 2BV5 161. Covers 50 Hz and 60 Hz operation, voltage variants 230Δ/400Y, 265Δ/460Y, 400Δ/690Y, 460Δ, 500Δ, 575Δ, and material variants K (cast iron casing with ceramic coating, bronze port plate) and H (CrNi steel casing, port plate and impeller).
Technical Data
| Parameter |
Value |
Condition |
| Suction capacity |
300 m³/h
p.2 ↗ |
2BV5 161, 50 Hz, material K |
| Suction capacity |
304 m³/h
p.2 ↗ |
2BV5 161, 60 Hz, material H |
| Rated voltage |
230 ∆/ 400 Y V
p.2 ↗ |
50 Hz |
| Rated voltage |
265 ∆/ 460 Y V
p.2 ↗ |
60 Hz |
| Rated voltage |
400 ∆/ 690 Y V
p.2 ↗ |
50 Hz |
| Rated voltage |
460 ∆ V
p.2 ↗ |
60 Hz |
| Rated voltage |
500 ∆ V
p.2 ↗ |
50 Hz |
| Rated voltage |
575 ∆ V
p.2 ↗ |
60 Hz |
| Current |
51,0 ∆ / 29,5 Y A
p.2 ↗ |
50 Hz, 230∆/400Y |
| Current |
∆/ 28 Y A
p.2 ↗ |
60 Hz, 265∆/460Y |
| Current |
29,5 ∆ / 17 Y A
p.2 ↗ |
50 Hz, 400∆/690Y |
| Current |
28,0 ∆ A
p.2 ↗ |
60 Hz, 460∆ |
| Current |
23,5 ∆ A
p.2 ↗ |
50 Hz, 500∆ |
| Current |
22,5 ∆ A
p.2 ↗ |
60 Hz, 575∆ |
| Power |
12,40 kW
p.2 ↗ |
50 Hz |
| Power |
16,00 kW
p.2 ↗ |
60 Hz |
| Service factor |
1,21
p.2 ↗ |
50 Hz |
| Service factor |
1,03
p.2 ↗ |
60 Hz |
| Operation liquid quantity |
2,40 m³/h
p.2 ↗ |
50 Hz / 60 Hz |
| Sound pressure level |
74 dB(A)
p.2 ↗ |
50 Hz |
| Sound pressure level |
75 dB(A)
p.2 ↗ |
60 Hz |
| Weight |
300 kg
p.2 ↗ |
material K |
| Weight |
304 kg
p.2 ↗ |
material H |
| Max. water carry-over |
6 m³/h
p.2 ↗ |
50 Hz and 60 Hz |
| Back pressure |
1300 mbar atm.
p.2 ↗ |
50 Hz and 60 Hz |
Operating Limits
- Ultimate pressure (inlet pressure): 33 mbar abs.
p.1 ↗
- Cavitation-free operation down to: 80 mbar abs.
p.1 ↗
- Protection category: IP55
p.1 ↗
- Max. back pressure: 1300 mbar atm.
p.2 ↗
- Max. water carry-over: 6 m³/h
p.2 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-6
p.2 ↗ |
2BV5161 |
Model range L-BV5, size 161 |
| field 1
p.2 ↗ |
0 |
Design variant |
| field 2
p.2 ↗ |
Q |
Voltage code (Q = standard voltage range) |
| field 3
p.2 ↗ |
1, 5, 6, 7 |
Voltage variant: 1 = 200-240V∆/310-415VY (50 Hz) / 200-275V∆/350-480VY (60 Hz); 5 = 450-550V∆ (50 Hz) / 520-600V∆ (60 Hz); 6 = 200-260V∆/350-450VY (50 Hz) / 230-290V∆/400-500VY (60 Hz); 7 = 350-450V∆/610-725VY (50 Hz) / 400-500V∆/690-725VY |
| suffix
p.2 ↗ |
K |
Material variant: cast iron casing with ceramic coating, bronze port plate |
| suffix
p.2 ↗ |
H |
Material variant: CrNi steel casing, port plate and impeller |