BINDER CB 56
BINDER ·Made in Germany · In Active Production

BINDER CB 56

BINDER CB 56 — Incubators with Temperature 4…50 °C.

The BINDER CB 56 is a 53 L CO2 incubator with hot-air sterilization and a heat-sterilizable IR CO2 sensor, available in 200–230 V (CB056-230V) and 100–120 V UL (CB056UL-120V) variants. It operates from +4 to 50 °C with 0.1 K fluctuation and 0.3 K uniformity, and provides 90–95 % RH via the Permadry water pan. It is distinguished within the CB series by its compact 53 L chamber, suited to small-scale cell culture where reproducible CO2 control and in-chamber sterilization are required.

Temperature
4…50 °C

Direct drop-in replacements

⚖️ Compare
⚖️ Compare
⚖️ Compare
⚖️ Compare

BINDER CB Series — Model Comparison & Selection

Model Temperature, °CDepth, cmHeight, cmHumidity range, % rhInterior volume, LPermitted load, kg
CB 56 Current 4–5054.567.490...955330
CB 170 4–5071.58790 ...9517030
CB 260 5–5078.510290...9526740

Full specifications

Core Performance & Functional Specifications
Temperature 4...50 °C
CO2 measuring technology IR
Interior volume 53 L (CB056-230V / CB056UL-120V)
Load per rack 10 kg (CB056-230V / CB056UL-120V)
Nominal power 0.8 kW
Permitted load 30 kg (CB056-230V / CB056UL-120V)
Temperature fluctuation 0.1 K
Temperature uniformity 0.3 K
Back wall clearance 100 mm (CB056-230V / CB056UL-120V)
Side wall clearance 50 mm (CB056-230V / CB056UL-120V)
Article Number mfr 9040
Recovery time after door was opened for 30 s at 37°C mfr 5 min
CO2 recovery time after door was opened for 30 s at 5 vol. % CO2 mfr 5 min
Dimensions, Weight & Mechanical Design
Depth 545 mm (CB056-230V / CB056UL-120V)
Height 674 mm (CB056-230V / CB056UL-120V)
Width 528 mm (CB056-230V / CB056UL-120V)
Electrical, Power & Drive Specifications
Power frequency 50 Hz
Rated voltage 200...230 V
Unit fuse 10.0 A
Phase (Nominal voltage) mfr 1
Operating Conditions, Environment & Protection
Humidity range 90...95 % RH

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection, and control specifics

Integration & Operating Notes

Maintenance
Replace door gasket only when chamber is cold

Replacing the door gasket while the chamber is warm can damage the gasket material. Always allow the chamber to cool to ambient temperature before attempting replacement.

Operating Manual CB+CBF (E7.1), Section 22.5
Control & I/O
Alarm delay prevents nuisance trips during door openings

The MB2 controller allows setting alarm delay times for temperature, CO2, and door opening. Configure these delays to avoid false alarms during routine door access, but keep them short enough to detect real deviations.

Operating Manual CB+CBF (E7.1), Section 11.5
Maintenance
Annual electrical safety test required per EN 50678/50699

An electrical safety inspection according to EN 50678/VDE 0701 and EN 50699/VDE 0702 must be performed before initial startup and after any maintenance or repair, and is recommended annually. This ensures continued safe operation.

Operating Manual CB+CBF (E7.1), Section 22.1

Selection & Integration Q&A

When should I choose the CB 56 over the larger CB 170 or CB 260?

Choose the CB 56 for small-scale cell culture where 53 L capacity suffices and bench space is limited. The CB 170 and CB 260 offer larger volumes (170 L and 260 L) but share the same temperature range and control features. Select the larger models for higher throughput or when working with multiple racks.

What gas supply accessories are required for CO2 control?

A CO2 gas cylinder connection kit is required (available as accessory). For O2 control (if equipped), additional O2 and N2 connection kits are needed. Ensure the gas supply pressure matches the chamber's inlet requirements as specified in the manual.

What are the duty-cycle limitations for the hot-air sterilization cycle?

The sterilization cycle takes 10 hours total: 4 hours effective sterilization (heating and holding) followed by 6 hours cooling to 37 °C. CO2 control is deactivated during this period and reactivates only after successful confirmation and cooling below 80 °C. Plan experiments around this downtime.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the chamber and standard accessories. Optional accessories such as gas cylinder connection kits, APT-COM 4 software, silicone access ports, and stacking adapters must be ordered separately. Annual maintenance by BINDER Service is recommended, and the CO2 sensor may need periodic replacement and recalibration.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Data Sheet Model CB 56 en
Datasheet ·466,0 КБ ·7 pp.
View PDF
PDF
CB+CBF (E7.1) 01 2026 en
Manual ·19,4 МБ ·201 pp.
View PDF