Elmo Rietschle 2BL2041
Elmo Rietschle 2BL2041 — Liquid Ring Vacuum Pumps.
The 2BL2041 is a single-stage, oil-free liquid-ring vacuum pump from Elmo Rietschle's L-BL2 'Pump in a Box' series, supplied as a compact circuit with an IE3 AC motor in IP55 protection. It is distinguished within the series by its oil-free operation and air cooling, positioning it between smaller and larger liquid-ring siblings. Its primary purpose is to generate vacuum in processes where oil contamination is unacceptable and a simple, self-contained package is preferred.
Elmo Rietschle L-BL2 Series — Model Comparison & Selection
| Model | Lubrication type | Operating principle | Motor power, kW | Power supply | Weight, kg | Noise level, dB |
|---|---|---|---|---|---|---|
| 2BL2041 Current | oil-free | liquid ring | — | AC | 69 | — |
| 2BL2061 | oil-free | liquid ring | 4.3 | 3~ AC | 73 | 64 |
| 2BL2101 | oil-lubricated | Venturi | — | AC | — | 78 |
| 2BL2141 | oil-lubricated | liquid ring | 3.4 | AC | 101 | 78 |
| 2BL2251 | oil-free | liquid ring | 5.6 | AC | 76 | 71 |
| 2BL2281 | oil-free | liquid ring | 5.5 | AC | 73 | 78 |
| 2BL2341 | dry | liquid ring | 7 | AC | 261 | — |
| 2BL2501 | oil-lubricated | liquid ring | 15 | AC | 583 | 72 |
Full specifications
| Lubrication type | oil-free |
| Operating principle | liquid ring |
| Number of stages | 1 dimensionless |
| Weight | 69 kg |
| Power supply | AC |
| Protection rating | IP55 |
| Cooling type | air |
Description
Construction and series positioning
- Single-stage liquid-ring principle with oil-free lubrication; no oil carryover into the process stream.
- Compact 'Pump in a Box' architecture integrates pump, motor and circuit in one enclosure.
- Air-cooled design eliminates the need for a separate cooling-water circuit for the pump itself.
- Weighs 69 kg, with IP55 protection and insulation class F motor.
- Within the L-BL2 series, the 2BL2041 is the oil-free liquid-ring variant; siblings include the 2BL2061 (oil-free, 4.3 kW), 2BL2141 (oil-lubricated, 3.4 kW) and 2BL2251 (oil-free, 4.2 kW). The 2BL2101 is a Venturi-type unit and not directly comparable.
Behavior under load and media
- As a liquid-ring pump, vacuum is generated by a rotating liquid ring; the working liquid (typically water) must be supplied and maintained.
- Oil-free operation means the pumped gas contacts only the working liquid and the pump internals, making it suitable for applications where oil mist is prohibited.
- No digitized curve points were provided; performance data should be taken from the technical data sheet for the specific motor voltage variant.
- The pump is air-cooled, so adequate ambient airflow is required; operation in enclosed spaces without ventilation may derate performance.
Installation, connection and operation
- The data sheet covers motor voltage variants K50-1B, K50-6B, Q50-3B and Q50-7B for the 2BL2041-2; the correct variant must be specified for the site supply.
- Electrical connection is 3-phase AC, 50/60 Hz, with IP55 protection; the motor is IE3 efficiency class.
- The compact package requires only process inlet/outlet connections and a working-liquid supply; no external oil system is needed.
- Control and monitoring details are not included in the provided digest; refer to the full instruction manual for startup, shutdown and interlock logic.
Integration & Operating Notes
The 2BL2041-2 is offered in four motor voltage variants (K50-1B, K50-6B, Q50-3B, Q50-7B). Connecting a motor wound for one voltage to a different supply will cause overheating, loss of torque or immediate failure. Verify the nameplate against the site voltage and frequency before commissioning.
The pump is air-cooled, so it must be installed with sufficient clearance around the enclosure for convective airflow. Restricting airflow or placing the unit in a hot, enclosed cabinet will reduce cooling capacity and may lead to motor overheating or reduced vacuum performance.
As a liquid-ring pump, the working liquid (typically water) must be clean and compatible with the pump internals. Contaminated or scaling water can clog the ring circuit, reduce achievable vacuum and accelerate wear. A strainer or filtration on the liquid supply is recommended where particulate is present.
Selection & Integration Q&A
Choose the 2BL2041 when oil-free liquid-ring vacuum is required and the duty fits its single-stage performance. The 2BL2061 offers higher motor power (4.3 kW) for greater capacity; the 2BL2141 is oil-lubricated and suited where oil carryover is acceptable. The 2BL2041 is the oil-free option in this power band.
The pump is air-cooled, so it must be installed with adequate ventilation and ambient temperature within the motor's rating. Continuous duty is assumed for a liquid-ring pump; frequent starts or high ambient may require derating. Refer to the instruction manual for exact ambient limits and duty-cycle guidance.
Oil-free design eliminates oil changes, but the working liquid circuit requires periodic inspection for contamination and scaling. The base delivery does not include process piping, liquid supply fittings or electrical cables; these must be sourced separately. Refer to the manual for service intervals on seals and bearings.