Elmo Rietschle 2BL2141
Elmo Rietschle 2BL2141 — Liquid Ring Vacuum Pumps with Motor power 3.4 kW.
The 2BL2141 is an oil-lubricated liquid ring vacuum pump from the L-BL2 series, driven by a 3.4 kW AC motor and protected to IP55. It is the oil-lubricated modification within a series that also includes oil-free liquid ring and Venturi variants, distinguishing it by its lubrication method rather than a different operating principle. Its primary purpose is to generate vacuum in industrial systems where an oil-lubricated liquid ring pump is acceptable and a compact, air-cooled package is required.
Elmo Rietschle L-BL2 Series — Model Comparison & Selection
| Model | Lubrication type | Operating principle | Motor power, kW | Power supply | Weight, kg | Noise level, dB |
|---|---|---|---|---|---|---|
| 2BL2141 Current | oil-lubricated | liquid ring | 3.4 | AC | 101 | 78 |
| 2BL2041 | oil-free | liquid ring | — | AC | 69 | — |
| 2BL2061 | oil-free | liquid ring | 4.3 | 3~ AC | 73 | 64 |
| 2BL2101 | oil-lubricated | Venturi | — | AC | — | 78 |
| 2BL2251 | oil-free | liquid ring | 5.6 | AC | 76 | 71 |
| 2BL2281 | oil-free | liquid ring | 5.5 | AC | 73 | 78 |
| 2BL2341 | dry | liquid ring | 7 | AC | 261 | — |
| 2BL2501 | oil-lubricated | liquid ring | 15 | AC | 583 | 72 |
Full specifications
| Lubrication type | oil-lubricated |
| Motor power | 3.4 kW (50 Hz) 60 Hz: 3.4 kW |
| Operating principle | liquid ring |
| Weight | 101 kg |
| Power supply | AC |
| Noise level | 78 dB |
| Operating temperature | F |
| Protection rating | IP55 |
| Cooling type | air |
Description
Construction and series positioning
- The 2BL2141 is a liquid ring vacuum pump with oil-lubricated bearings and an air-cooled heat rejection path.
- It shares the liquid ring operating principle with siblings 2BL2041, 2BL2061 and 2BL2251, but is the only oil-lubricated liquid ring model listed; 2BL2101 is a Venturi-type pump and is not a liquid ring machine.
- The 3.4 kW motor is available in both 50 Hz and 60 Hz variants, and the datasheet ordering code covers both 50 Hz and 60 Hz voltage variants (K50-1B, K50-6B, Q50-7B).
- With a mass of 101 kg and IP55 protection, the unit is a compact floor- or base-mounted package rather than a split close-coupled assembly.
Behavior under load and media
- No digitized curve points were supplied for this model, so performance must be taken from the datasheet ordering-code variants rather than interpolated.
- The liquid ring principle means the pump requires a service liquid (typically water) to form the ring; the oil-lubricated designation refers to the bearing/shaft lubrication, not to the ring fluid.
- Air cooling is the only cooling type listed; there is no external heat exchanger or cooling-water circuit specified for this modification.
- The 78 dB noise level and 3.4 kW motor power are the only quantified operating data available; no inlet pressure or suction capacity values are given in the verified facts.
Installation, connection and control
- The technical data sheet defines the ordering code as 2BL2141-2 □ K50-1B / K50-6B / Q50-7B, so the voltage and frequency variant must be fixed at order time.
- IP55 protection permits installation in dusty or hose-down environments, but the air-cooled motor still needs unobstructed ventilation.
- No control, I/O or interlock details are present in the supplied document digest; these must be obtained from the full instruction manual before commissioning.
Integration & Operating Notes
The ordering code 2BL2141-2 □ K50-1B / K50-6B / Q50-7B defines distinct 50 Hz and 60 Hz voltage variants. Supplying the wrong voltage or frequency variant will change the motor speed and therefore the vacuum performance, and may overload the 3.4 kW winding. Confirm the site supply before placing the order.
The pump is air-cooled and rated IP55. Enclosing it in a tight cabinet or placing it against a wall will reduce heat rejection and raise winding temperature. Maintain clear space around the fan cowl and avoid recirculating hot exhaust air into the intake.
As a liquid ring pump, the 2BL2141 needs a service liquid to form the sealing ring. The oil-lubricated designation covers bearings and shaft sealing, not the ring fluid. Loss of service liquid will cause the pump to lose vacuum and may damage the impeller and casing.
Selection & Integration Q&A
Choose the 2BL2141 when an oil-lubricated bearing arrangement is acceptable and a 3.4 kW motor matches the duty. Select an oil-free sibling when the process cannot tolerate any oil ingress, or when a different motor power (e.g. 4.35 kW on 2BL2061 or 5.6 kW on 2BL2251) is required.
The motor is 3.4 kW AC, available in both 50 Hz and 60 Hz variants, with IP55 protection. The exact voltage variant is set by the ordering code suffix (K50-1B, K50-6B or Q50-7B), so the starter and protection settings must be matched to the ordered variant, not to a generic 3.4 kW rating.
The pump is oil-lubricated, so lubricant changes are part of routine service; the datasheet does not specify intervals, so follow the full instruction manual. Service liquid for the liquid ring must be provided by the plant. Electrical cables, starters and mating pipework are not part of the base pump delivery.