Elmo Rietschle 2BL2341
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BL2341

Elmo Rietschle 2BL2341 — Liquid Ring Vacuum Pumps with Motor power 7 kW, Pumping speed 250 m³/h.

The 2BL2341 is a dry-running, liquid-ring vacuum pump in the L-BL2 series, driven by a 7.0 kW IE3 motor and delivering 250 m³/h at 50 Hz or 300 m³/h at 60 Hz. Its cast-iron body with ceramic-coated internal surfaces distinguishes it from smaller or oil-lubricated siblings, making it suitable for continuous oil-free vacuum generation in industrial processes.

Motor power
7 kW
Pumping speed
250 m³/h

Elmo Rietschle L-BL2 Series — Model Comparison & Selection

Model Lubrication typeOperating principleMotor power, kWPower supplyWeight, kgNoise level, dB
2BL2341 Current dryliquid ring7AC261—
2BL2041 oil-freeliquid ring—AC69—
2BL2061 oil-freeliquid ring4.33~ AC7364
2BL2101 oil-lubricatedVenturi—AC—78
2BL2141 oil-lubricatedliquid ring3.4AC10178
2BL2251 oil-freeliquid ring5.6AC7671
2BL2281 oil-freeliquid ring5.5AC7378
2BL2501 oil-lubricatedliquid ring15AC58372

Full specifications

Core Performance & Functional Specifications
Lubrication type dry (oil free)
Motor power 7.0 kW
Operating principle liquid ring
Pumping speed 250 m³/h (50 Hz)
60 Hz: 300 m³/h
Nominal size / model mfr 2BL2 341
Service factor mfr 1.30
Efficiency mfr 90.0 %
Order No. mfr 253 00
Dimensions, Weight & Mechanical Design
Weight 261 kg (Cast iron (internal surface with ceramic coating))
Partially stainless steel version: 253 kg
Electrical, Power & Drive Specifications
Power supply AC (3~)
Voltage range mfr 550-600 V Y (50 Hz)
Voltage range mfr 550-600 V Y (60 Hz)
Voltage range mfr 400 V Δ / 690 V Y
Current mfr 22.5 A
Current mfr 9.7 A (50 Hz)
Current mfr 9.7 A (60 Hz)
Efficiency class mfr IE3
Operating Conditions, Environment & Protection
Protection rating IP55
Cooling type air
Sound pressure level mfr 70 dB(A)
Standards, Safety & General Data
UL certificate number mfr E489378

Description

Construction and series positioning

Operating behaviour

Electrical and control interface

Integration & Operating Notes

Electrical
Verify motor connection matches 400 V Δ or 690 V Y supply

The motor is wound for dual voltage (400 V Δ / 690 V Y) and also listed for 550–600 V Y at 50/60 Hz. Connecting the motor to the wrong voltage or winding configuration will exceed insulation limits or reduce torque; confirm the terminal-box link arrangement against the nameplate before first start.

Technical Data Sheet — L-BL2 2BL2341 IE3 vacuum pump, Electrical Data
Process Limits
Seal-liquid quality and supply determine achievable vacuum

As a liquid-ring pump, the 2BL2341 requires a seal liquid to form the ring. The data sheet does not specify a seal-liquid flow or temperature range for this model, so the system designer must provide a compatible liquid supply and ensure it is available before the pump is loaded; dry running without the ring liquid will not generate the rated vacuum and can damage the pump.

Technical Data Sheet — L-BL2 2BL2341 IE3 vacuum pump, Operating Principle
Maintenance
No lubrication schedule; inspect seal-liquid circuit instead

Because the pump is dry (oil-free), there is no oil change interval. Maintenance attention should focus on the seal-liquid supply, strainers, and coupling alignment. The data sheet does not define service intervals for this model; establish a site-specific inspection plan based on operating hours and seal-liquid condition.

Technical Data Sheet — L-BL2 2BL2341 IE3 vacuum pump, Lubrication

Selection & Integration Q&A

When should I choose the 2BL2341 instead of the smaller 2BL2061 or the oil-lubricated 2BL2141?

Choose the 2BL2341 when you need 250–300 m³/h oil-free vacuum and a 7.0 kW IE3 drive. The 2BL2061 is only 4.35 kW and lower capacity; the 2BL2141 is oil-lubricated and not suitable for oil-free process gas.

What starter and cable sizing must be provided for the 2BL2341 motor?

The motor draws 22.5 A at 400 V Δ and 9.7 A at 690 V Y. Size the contactor, overload and cable for the actual supply voltage and starting method; no starter or cable is included in the base delivery.

What maintenance and accessories are required beyond the base pump?

No oil changes are needed, but the seal-liquid circuit, strainers and coupling must be inspected regularly. The base delivery does not include a seal-liquid supply system, starter, or suction/discharge fittings; these must be specified separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BL2 2BL2341 IE3 vacuum pump (EN)
Datasheet ·270,7 КБ ·3 pp.
View PDF