Elmo Rietschle 2BV5110
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV5110

Elmo Rietschle 2BV5110 — Liquid Ring Vacuum Pumps with Motor power 5.5 kW.

The 2BV5110 is a monoblock liquid ring vacuum pump/compressor from the L-BV5 series, driven by a 5.5 kW IE3 motor for 50/60 Hz operation. It is the base 5.5 kW modification in the series, positioned below the 7.5 kW 2BV5111 and above smaller L-BV2 types, and is intended for continuous vacuum generation where a compact, close-coupled unit with IP55 protection is required.

Motor power
5.5 kW

Elmo Rietschle L-BV5 Series — Model Comparison & Selection

Model Motor power, kWOperating principleNoise level, dBPower supplyPumping speed, m³/hWeight, kg
2BV5110 Current 5.5ring blow67AC—67
2BV5111 7.5Liquid ring723~ AC—124
2BV5121 11Liquid ring compressor70AC40—
2BV5131 15Liquid ring74AC17.4178
2BV5161 15Liquid ring74AC500160
L-BV5 2060 ——————

Full specifications

Core Performance & Functional Specifications
Motor power 5.5 kW (50 Hz)
60 Hz: 5.5 kW
Operating principle ring blow
Design (alt var) mfr monoblock
Dimensions, Weight & Mechanical Design
Weight 67 kg
Electrical, Power & Drive Specifications
Power supply AC (3~ 50/60 Hz)
Operating Conditions, Environment & Protection
Noise level 67 dB(A)
Protection rating IP55
Sound pressure level (alt var) mfr 61 dB(A)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Mounting
Keep vibration below 4.5 mm/s to avoid bearing damage

The maximum permissible vibration velocity is 4.5 mm/s. Measure at the points shown in Fig. 7 after installation. Exceeding this limit indicates misalignment, pipe strain, or foundation issues that can lead to premature bearing failure and seal damage.

Operating Instructions — L-BV2 (EN), Installation, page 15
Process Limits
Discharge pressure must not exceed 1.3 bar abs in vacuum duty

In vacuum operation, the maximum discharge pressure is 1.3 bar abs for 2BV5.. types. Ensure the system downstream cannot impose higher pressure; install appropriate protection if higher pressures can occur. The maximum permissible internal pressure is 8 bar abs.

Operating Instructions — L-BV2 (EN), Technical data, page 10
Electrical
Verify motor insulation resistance before first start

Measure insulation resistance before commissioning. If the value is ≤1 kΩ per volt of measurement potential, the windings must be dried. Starting with low insulation resistance can cause motor failure or earth faults.

Operating Instructions — L-BV2 (EN), Commissioning, page 20
Electrical
Frequency converter operation limited to 1402–2454 min⁻¹

When driven by a frequency converter, the speed must stay within 1402–2454 min⁻¹ for the 2BV5110 (covers both 50 Hz and 60 Hz operation). Exceeding this range can cause cavitation, vibration, or motor overload. For ATEX versions, frequency converter operation is not permitted at all.

Operating Instructions — L-BV2 (EN), Technical data, page 9
Maintenance
Replace or re-grease bearings every 2.5 years or 20,000 hours

Bearing maintenance is due every 2.5 years or 20,000 operating hours, whichever comes first. Use UNIREX N3 grease (or DIN 51825-K3N equivalent) and fill approximately 50% of the free space in roller bearings and 65% of adjacent areas. Do not mix grease types.

Operating Instructions — L-BV2 (EN), Maintenance, page 28
Maintenance
Fit a suction strainer for the first 100 operating hours

To prevent installation residues (weld slag, scale, debris) from entering the pump and damaging the impeller or casing, install a temporary intake strainer in the suction line. Remove or clean it after the first 100 operating hours.

Operating Instructions — L-BV2 (EN), Installation, page 16
Process Limits
Operating liquid must be between +5 °C and +80 °C

The operating liquid temperature must be maintained between +5 °C and +80 °C, with a nominal value of +15 °C. Temperatures outside this range affect vacuum performance and can cause cavitation or seal damage. Ensure the liquid supply system can maintain this temperature.

Operating Instructions — L-BV2 (EN), Technical data, page 10

Selection & Integration Q&A

When should I choose the 2BV5110 over the 2BV5111 or 2BV5121?

Choose the 2BV5110 when your required vacuum level and pumping speed are met by its 5.5 kW motor, which is the lowest power in the L-BV5 series. The 2BV5111 offers 7.5 kW for higher capacity, and the 2BV5121 11.0 kW for even greater flow. Select the smallest motor that covers the duty point to minimize energy use and frame size.

What are the requirements for the suction and discharge piping connected to the 2BV5110?

Piping must be supported independently and connected without strain. Tightening torque for the suction and discharge connections must not exceed 100 Nm. Install an intake strainer for the first 100 operating hours. Ensure the discharge line cannot impose more than 1.3 bar abs during vacuum operation.

What ambient and installation conditions must be respected for the 2BV5110?

Ambient temperature must stay between +5 °C and +40 °C. Maximum installation altitude is 1000 m above sea level; consult the manufacturer if higher. Maintain a minimum clearance of 53 mm around the fan guard for heat dissipation. Vibration velocity at the installation must not exceed 4.5 mm/s.

What maintenance items and accessories are required but not included with the base pump?

The base delivery does not include the operating liquid, suction strainer, or monitoring devices. You must provide an operating-liquid supply system with flow control; the first fill quantity for the 2BV5110 is 3.0 L. For ATEX installations, mandatory monitoring includes liquid level, flow, and discharge pressure switches. Bearings require UNIREX N3 grease every 2.5 years or 20,000 hours.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Technical Data Sheet — L-BV5 2BV5110 IE3 compressor (EN)
Datasheet ·442,0 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF