Operating Instructions — L-BV2 (EN)

Technical Reference Summary

Covered Models & Document Scope

Covers liquid ring vacuum pumps/compressors of the L-BV2 and L-BV5 series in standard design: 2BV2060, 2BV2061, 2BV2070, 2BV2071, 2BV5110, 2BV5111, 2BV5121, 2BV5131, 2BV5161, 2BV5410, 2BV5411, 2BV5421, 2BV5470, 2BV5471. Variants include cast iron and stainless steel constructions (stainless only for 2BV2070, 2BV2071, 2BV51..), bronze 2BV5410-.F, cast iron 2BV5410-1G, and explosion-protected designs (covered by separate supplementary instructions, not this manual).

Section-by-Section Technical Breakdown

pp. 8-9
Mechanical data

Provides weights by type and material, minimum clearances for heat dissipation, noise levels at 50/60 Hz, operating speeds, maximum speeds with frequency converters, and tightening torques for non-electrical, electrical, and threaded gland connections.

  • Weights range from 25 kg (2BV2060 cast iron) to 264 kg (2BV5161 stainless steel).
  • Minimum fan-guard clearance: 34 mm for 2BV206., 53 mm for most others, 80 mm for 2BV5161.
  • Sound pressure level 70–77 dB(A) at 1 m, tolerance ±3 dB(A).
  • Standard speeds: 2BV2… 3000/3600 min-1; 2BV5110–2BV5131 and 2BV54.. 1500/1800 min-1; 2BV5161 1000/1200 min-1.
  • Maximum frequency-converter speeds range from 1597 min-1 (2BV5161) to 4612 min-1 (2BV2060/2061).
  • Tightening torques: M4 2.7–3.3 Nm, M5 3.6–4.4 Nm, M6 7.2–8.8 Nm, M8 21.6–26.4 Nm, M10 37.8–46.2 Nm, M12 63.0–77.0 Nm, M16 90–110 Nm for non-electrical connections.
pp. 10-13
Electrical data and operating conditions

Electrical data refers to the motor rating plate. Operating conditions specify temperature limits for gases/vapours, operating liquid, and ambient air, maximum discharge pressures for vacuum and compressor operation, maximum internal pressure, minimum achievable suction pressure with cavitation notes, design operating-liquid flows, first-fill quantities, and maximum permissible water carry-over.

  • Max gas/vapour temperature +80 °C; operating liquid +5 to +80 °C (nominal +15 °C); ambient +5 to +40 °C.
  • Max discharge pressure for vacuum operation: 1.1 bar abs (2BV2…), 1.3 bar abs (2BV5…).
  • Max internal pressure: 8 bar abs for most types, 6 bar abs for 2BV5410-.F.
  • Design operating-liquid flow depends on type and pressure range; first fill 0.5–8.0 L.
  • Maximum water carry-over: 2.5x design flow continuous, 7x for max 2 s (2BV2…); 2.5x/5x for 2BV51..; 7x/7x for 2BV5410-.F; absolute limits for 2BV541.-1G, 2BV542., 2BV547.
pp. 15-19
Installation

Covers setup conditions, mechanical connection of suction/discharge and operating-liquid lines, connection of system components, ancillaries, and electrical motor connection including terminal box and frequency converter operation.

  • Set up on level, load-bearing surface, shaft horizontal, max altitude 1000 m, max vibration veff = 4.5 mm/s.
  • Bolt all mounting feet; intermediate plates supplied for 2BV5110-….2-.S, 2BV5121-….2-.S, 2BV5410-1G.
  • Suction/discharge tightening torque must not exceed 100 Nm.
  • Fit intake strainer for first 100 operating hours.
  • Operating-liquid connection sizes: G3/8 (2BV20, 2BV54..-1G), G3/4 (2BV51, 2BV54..-.F).
  • Electrical supply tolerance: ±5% voltage, ±2% frequency; air gaps ≥5.5 mm at UN ≤690 V.
pp. 20-21
Commissioning

Describes preparation, start-up with operating-liquid supply or self-suction, and checking direction of rotation. Includes warnings against dry running and requirements for pressure/leak testing and motor insulation resistance.

  • Do not switch on until system filled with operating-liquid; dry running destroys rotary seals within seconds.
  • Measure motor insulation resistance; dry windings if ≤1 kΩ per volt of measurement potential.
  • Ensure maximum outlet pressure is not exceeded.
  • Check piping/hose connections for leaks before start-up.
pp. 22-23
Operation

Covers operation with automatically controlled or non-automatic operating-liquid supply, operation with self-suction, and checking/correcting the operating-liquid flow-rate.

  • Operating-liquid flow must be maintained continuously during operation.
  • Flow-rate checking and correction procedures are referenced in chapter 7.4.
  • Self-suction operation requires initial filling of the operating chamber before piping installation.
pp. 24-25
Decommissioning and long-term shutdown

Covers draining down, preparations for long-term shutdown, storage conditions, and commissioning after a long shutdown period.

  • Drain operating liquid before long-term shutdown.
  • Follow storage conditions and recommissioning steps after extended idle periods.
pp. 26-30
Maintenance

Specifies maintenance intervals and procedures for bearings, seals, and valves, including grease type and filling quantities. Also includes repairs/troubleshooting and service information.

  • Re-grease or renew roller bearings every 2.5 years or 20,000 operating hours.
  • Fill approx. 50% of free space in roller bearings and approx. 65% of adjacent areas with grease.
  • Grease type: UNIREX N3 (ESSO Co.) or alternative per DIN 51825-K3N.
  • Check rotary seal, V-ring, and valve head for wear and replace if necessary.
  • Avoid mixing different grease types.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Maximum permissible vibration velocity veff = 4.5 mm/s [0.177 in/s]. p.15 ↗ Installation must ensure vibration levels stay below this limit to avoid damage; measure at points shown in Fig. 7. whole series
Maximum installation altitude: 1000 m [3280 ft] above sea level. p.15 ↗ Consult service department if installation altitude exceeds this value. whole series
Tightening torque for piping connections to suction and discharge must not exceed 100 Nm [73.8 ft lbs]. p.16 ↗ Avoid over-tightening piping to prevent damage to connections. whole series
Intake strainer should be fitted in suction line for the first 100 operating hours. p.16 ↗ Prevents installation residues from entering the unit during initial operation. whole series
Electrical supply tolerance: ±5% voltage variation and ±2% frequency deviation without loss of performance. p.18 ↗ Verify power supply quality at installation site. whole series
Minimum air gap between non-insulated energized components and to earth: 5.5 mm [0.217 in] at design voltage UN ≤ 690 V. p.19 ↗ Ensure terminal box wiring maintains this clearance. whole series
Motor insulation resistance: dry windings if ≤1 kΩ per volt of measurement potential. p.20 ↗ Check before commissioning to avoid motor failure. whole series
Maximum gas/vapour temperature: +80 °C [176 °F]. p.10 ↗ For higher temperatures, increase operating-liquid flow to 2.5x (2BV2…) or 2x (2BV5…) design flow or install pre-condenser, and provide guards against burns. whole series
Operating-liquid temperature range: +5 °C to +80 °C, nominal +15 °C. p.10 ↗ Maintain operating-liquid temperature within limits for proper performance. whole series
Ambient temperature range: +5 °C to +40 °C. p.10 ↗ Ensure installation environment stays within these limits. whole series
Max discharge pressure for vacuum operation: 1.1 bar abs (2BV2…), 1.3 bar abs (2BV5…). p.10 ↗ Do not exceed these pressures when design operating-liquid flow is maintained. 2BV2… and 2BV5…
Max permissible internal pressure: 8 bar abs for most types, 6 bar abs for 2BV5410-.F. p.10 ↗ Install appropriate protection devices if higher pressures can occur in the system. whole series
Design operating-liquid flow for 2BV2060: 0.20 m³/h in all pressure ranges. p.12 ↗ Set flow limiter accordingly for proper operation. 2BV2060
First fill quantity of operating liquid: 0.5 L for 2BV206., 1.0 L for 2BV207., 3.0 L for 2BV511., 2BV5121, 2BV5131, 8.0 L for 2BV5161, 2.0 L for 2BV547., 3.0 L for 2BV541., 2BV5421. p.12 ↗ Use correct quantity when filling before start-up. specific types
Maximum water carry-over through inlet: 2.5x design flow continuous, 7x for max 2 s (2BV2…); 2.5x/5x for 2BV51..; 7x/7x for 2BV5410-.F; 6 m³/h for 2BV541.-1G; 5 m³/h for 2BV542. and 2BV547. p.13 ↗ Ensure liquid separation prevents exceeding these limits. specific types
Bearing maintenance interval: 2.5 years or 20,000 operating hours. p.28 ↗ Schedule re-greasing or bearing replacement accordingly. whole series
Grease type: UNIREX N3 (ESSO Co.) or alternative per DIN 51825-K3N; fill approx. 50% of free space in roller bearings and approx. 65% of adjacent areas. p.28 ↗ Use specified grease and filling quantities; avoid mixing grease types. whole series
Minimum clearances for heat dissipation: 34 mm for 2BV206., 53 mm for 2BV207., 2BV511., 2BV5121, 2BV5131, 2BV54.., 80 mm for 2BV5161. p.8 ↗ Maintain these clearances around fan guard to prevent overheating. specific types
Maximum speeds with frequency converter: 2BV2060/2061 2636–4612 min-1; 2BV2070/2071 2123–3715 min-1; 2BV5110/5111 1402–2454 min-1; 2BV5121 1290–2258 min-1; 2BV5131 1180–2066 min-1; 2BV5161 913–1597 min-1; 2BV54.. 1402–2454 min-1. p.9 ↗ Do not exceed these speeds when using frequency converters. specific types
Tightening torques for metal threaded glands: M12x1.5 4–6 Nm, M16x1.5 5–7.5 Nm, M25x1.5 6–9 Nm, M32x1.5 8–12 Nm. p.9 ↗ Use correct torque when installing cable glands. whole series

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Motor does not start p.28 ↗ Electrical power supply failure Check fuses, terminals and cables for continuity. Repair any break in continuity. Electrician
Motor does not start p.28 ↗ Impeller does not rotate freely To free it, rotate the shaft: 2BV2…: Screw in an M8 bolt of sufficient length into the shaft end on the external fan side. Use a wrench to turn the shaft manually. Remove the bolt. 2BV5…: Remove the fan guard. Turn the external fan by hand. Refit the fan guard. Operator
Motor does not start p.28 ↗ Impeller does not rotate freely (due to calcification) See "Decalcifying the unit", page 27. Operator
Motor does not start p.28 ↗ Impeller does not rotate freely (due to foreign matter) See "Flushing the pump casing", page 27. Operator
Motor does not start p.28 ↗ Impeller does not rotate freely (clearance issue) Check the clearance adjustment on the impeller and readjust if necessary. Service
Motor does not start p.28 ↗ Foreign matter in the unit Remove the foreign matter. Check that the unit functions correctly. Service
Motor does not start p.28 ↗ Defective impeller Replace the impeller. Service
Motor does not start p.28 ↗ Defective motor bearing Replace the motor bearing. Service
Circuit breaker trips out again after it has been switched on p.28 ↗ Short-circuit in the winding Check the winding. Electrician
Circuit breaker trips out again after it has been switched on p.28 ↗ Motor overloaded When operating with supply of the operating-liquid: Check the operating-liquid flow-rate and if necessary reduce it (see chapter 7.4, "Checking and correcting the operating-liquid flow-rate", page 23). Operator
Circuit breaker trips out again after it has been switched on p.28 ↗ Excessive backpressure in the discharge connection Reduce the backpressure. Operator
Circuit breaker trips out again after it has been switched on p.28 ↗ Proportion of liquid entrained in the main flow is too high Reduce the proportion of liquid. Operator