Elmo Rietschle 2BV5161
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV5161

Elmo Rietschle 2BV5161 — Liquid Ring Vacuum Pumps with Motor power 15 kW, Pumping speed 500 m³/h.

The 2BV5161 is a liquid-ring vacuum pump/compressor in the L-BV5 series, size 161, with a 15 kW motor and 500 m³/h pumping speed at 50 Hz. It is the largest standard variant in the series, distinguished by an 8 L first-fill operating-liquid volume and 80 mm minimum heat-dissipation clearance. It serves as the central vacuum source in systems requiring reliable, oil-free extraction of gases and vapours.

Motor power
15 kW
Pumping speed
500 m³/h

Elmo Rietschle L-BV5 Series — Model Comparison & Selection

Model Motor power, kWOperating principleNoise level, dBPower supplyPumping speed, m³/hWeight, kg
2BV5161 Current 15Liquid ring74AC500160
2BV5110 5.5ring blow67AC—67
2BV5111 7.5Liquid ring723~ AC—124
2BV5121 11Liquid ring compressor70AC40—
2BV5131 15Liquid ring74AC17.4178
L-BV5 2060 ——————

Full specifications

Core Performance & Functional Specifications
Motor power 15.0 kW (50 Hz)
60 Hz: 15.0 kW
Operating principle Liquid ring
Pumping speed 500 m³/h (50 Hz)
60 Hz: 575 m³/h
Rotational speed 50 Hz (50 Hz)
60 Hz: 60 Hz
Suction capacity (alt 60 Hz) mfr 660-725 m3/h (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 160 kg
Weight approx. (alt var) mfr 162 kg
Electrical, Power & Drive Specifications
Power supply AC
Rated motor power (alt 60 Hz) mfr 17.7 kW (60 Hz)
Operating Conditions, Environment & Protection
Noise level 74 dB(A)
Operating temperature Water (pH 6-9)
Protection rating IP55
Sound pressure level (alt var) mfr 75 dB(A)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Mounting
Maintain 80 mm clearance around fan guard

The 2BV5161 requires a minimum clearance of 80 mm for heat dissipation; insufficient clearance can cause overheating and reduced motor life. Ensure the installation location allows unobstructed airflow and consider ambient temperature limits of +5 °C to +40 °C.

Technical Data, page 8
Process Limits
Keep suction pressure above vapour pressure plus 50 mbar

Operating below this margin risks cavitation, which can damage the impeller and reduce performance. For ATEX versions, this is mandatory; for standard versions, it is a design guideline. Monitor suction pressure and ensure the operating liquid temperature (max +80 °C) is controlled.

ATEX Supplement, Section 3.3
Electrical
ATEX versions require independent monitoring systems

For ATEX category 2G units, liquid feed, liquid level, and discharge pressure monitoring must be functionally independent and must shut down the unit on fault. Do not share a single controller path; EN ISO 13849 implementation is recommended. Non-ATEX units have no such requirement.

ATEX Supplement, Section 5.2.3
Maintenance
Replace bearings every 2.5 years or 20,000 hours

Bearing maintenance interval is 2.5 years or 20,000 operating hours for standard versions; ATEX versions require service every 2 years or 18,000 hours by a service technician. Use UNIREX N3 grease or equivalent, filling 50% of bearing free space. Weekly dust removal is required for ATEX.

Maintenance, page 28; ATEX Supplement, Section 9.1
Process Limits
Do not exceed 100 Nm tightening torque on piping

Over-tightening suction and discharge connections can crack the casing or damage threads. Use a torque wrench and follow the specified limit. Also, install a suction strainer for the first 100 operating hours to prevent debris ingress.

Installation, page 16
Electrical
Verify motor insulation resistance before commissioning

Dry windings if insulation resistance is ≤1 MΩ per volt of measurement potential. This prevents motor failure due to moisture. Also ensure terminal box wiring maintains a minimum air gap of 5.5 mm between non-insulated energized components and to earth.

Commissioning, page 20; Installation, page 19

Selection & Integration Q&A

When should I choose the 2BV5161 over smaller siblings like 2BV5131 or 2BV5121?

Choose 2BV5161 for the highest flow in the series (500 m³/h at 50 Hz) and 15 kW motor. Siblings 2BV5131 and 2BV5121 offer lower flows and are suited for smaller duties. The 2BV5161 also has a larger first-fill volume (8 L) and requires more space for heat dissipation.

What are the requirements for the operating-liquid supply system when integrating this pump?

The operating liquid (water, pH 6–9) must be supplied at a design flow rate (refer to technical data) and with a maximum operating-liquid temperature of +80 °C. For ATEX versions, flow monitoring must trip at ≤50% of design flow, and liquid level must be maintained between 175 and 235 mm. A pressure-resistant separator is required on the suction side if used.

Can I install this pump outdoors or in a high-altitude location?

The standard ambient temperature range is +5 °C to +40 °C, and maximum installation altitude is 1000 m above sea level. For outdoor installation, provide protection against weather and ensure the IP55 rating is sufficient. Consult the manufacturer for altitudes above 1000 m.

What maintenance items and accessories are not included with the base pump?

The base delivery does not include operating liquid, suction strainer (recommended for first 100 hours), or monitoring sensors for ATEX. Grease for bearings (UNIREX N3) must be procured separately. For ATEX, accessories like separators and check valves must have bleeder resistance <10⁶ Ω and be assessed for the hazardous area.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BV5 2BV5161 IE3 compressor (EN)
Datasheet ·482,4 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF