Peter Huber Kältemaschinenbau Unichiller GL 1650w
Peter Huber Kältemaschinenbau Unichiller GL 1650w — Recirculating chillers.
The Unichiller GL 1650w is a water-cooled recirculating chiller delivering 165 kW at 20 °C, using R-744 refrigerant and a fixed-speed pressure pump. It is the larger sibling of the GL 1300w, intended for externally closed, high-load process loops where cooling water is available at 5–20 °C and 1–6 bar differential.
Peter Huber Kältemaschinenbau Unichiller GL Series — Model Comparison & Selection
| Model | Cooling capacity, W | Ambient temperature limit, °C | Controller | Cooling water connection | Cooling water differential pressure, bar | Cooling water pressure, psi |
|---|---|---|---|---|---|---|
| Unichiller GL 1650w Current | 165000 | 5–40 | Pilot ONE | G1 1/4 male | 1 | 87.02 |
| Unichiller GL 1300w | 130000 | 5–40 | Pilot ONE | G1 1/4 male | 1 | 87.02 |
Full specifications
| Expansion volume | 50 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 165 kW (at 20 °C) |
| Cooling water connection | G1 1/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled, CO2 (R-744, A1/H280) refrigeration circuit with a fixed-speed pressure pump and G1 1/4 male process connections.
- Delivers 165 kW cooling at 20 °C; the sibling GL 1300w is the smaller-capacity alternative in the same series.
- Controller: Pilot ONE with Ethernet, USB host/device and RS232; external Pt100 sensor input.
- Overall dimensions 918 × 963 × 1771 mm; IP20; safety class I/NFL.
Behavior under load and media
- Cooling capacity falls as cooling-water inlet temperature rises, and required cooling-water flow may increase; size the water supply for worst-case conditions.
- Cooling-water inlet must be 5–20 °C; below the condensation point, internal cooling-water pipes require insulation.
- Wetted cooling-water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; use compatible, low-chloride, non-corrosive water.
- Minimum filling capacity 17.5 l; expansion volume 50 l.
Installation, connection and control
- Requires 400 V 3~ 50 Hz supply; three-phase units below 63 A are supplied with cable but without plug.
- Voltage tolerance ±5% and frequency ±2%, but the combination −5% voltage with +2% frequency is not permitted.
- Leakage current exceeds 3.5 mA; a reliable protective earth is mandatory and RCD selection must account for it.
- Class A, Group 1 to EN55011; additional filtering or separation from sensitive equipment may be needed.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto; Process Safety mode releases maximum cooling on overtemperature trigger.
- Must be installed indoors, not in an ATEX zone, with 50–200 cm wall clearance per side for maintenance; leveling feet/parking brakes must be set before operation.
Integration & Operating Notes
Operating outside this range risks condensation, corrosion or reduced cooling performance; if the inlet falls below the condensation point, the cooling-water pipes inside the unit must be insulated. Verify the site water temperature before commissioning.
Insufficient differential pressure prevents proper cooling and may cause the unit to trip on high temperature. Maximum permissible pressure is 6 bar. Confirm the site water supply meets both limits before installation.
A reliable protective earth connection is mandatory, and RCD selection must account for the >3.5 mA leakage current. Three-phase units below 63 A are supplied with cable but without a plug, so a suitable plug and connection must be provided on site.
Voltage tolerance is ±5% with a simultaneous frequency tolerance of ±2%, but the combination of −5% voltage and +2% frequency is not allowed. Verify the supply quality against this rule to avoid compressor or electronics damage.
Free-standing models require this clearance on either side. The unit must be installed indoors at an illuminance of at least 300 lx and up to 2000 m altitude, and must not be installed or started up inside an ATEX zone.
Electrical lines directly below a water-cooled unit must be protected against liquid ingress from condensation. Also shut off the cooling-water supply even for short downtimes such as overnight to prevent water damage and corrosion.
The Pilot ONE allows the power-failure response to be set as OFF/Standby, ON, or Power Failure Auto. For exothermic processes, Process Safety mode releases maximum cooling capacity when the overtemperature trigger value is reached instead of switching off all poles.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. The unit uses R-744 (CO2) refrigerant with GWP 1 and classification A1, H280, which affects handling and safety requirements.
Selection & Integration Q&A
Choose the GL 1650w when your process requires 165 kW cooling at 20 °C; the GL 1300w is the smaller-capacity sibling. Both share the same series architecture, so select based on the required heat rejection at your worst-case cooling-water temperature.
Provide cooling water at 5–20 °C with a differential pressure of at least 1 bar and maximum 6 bar. Connections are G1 1/4 male, so plan adapters. Use compatible, low-chloride water; the circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.
Install indoors only, not in an ATEX zone, at 300–2000 lx and up to 2000 m altitude, with 50–200 cm wall clearance per side. Ambient temperature must be 5–40 °C. Shut off cooling water even for overnight downtime. Leveling feet/parking brakes must be set before operation.
Three-phase units below 63 A are supplied with cable but without a plug; a suitable plug and connection must be provided on site. Refrigerant circuit work must be performed by approved refrigeration/air-conditioning contractors. No accessories or consumables are listed in the verified facts.