Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH203602 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH2 0360-2: side channel blower with IE3-motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239). Covers performance stages 1-4 and voltage variants (D/Y, UU, U, Q, VD) at 50 Hz and 60 Hz.

Technical Data

Parameter Value Condition
Voltage 190-210 V p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz, D
Current 17.1 A p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz, D
Power at pump shaft 4.6 kW p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz
Vacuum -420 mbar p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz
Pressure 370 mbar p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz
Sound pressure level 65 dB(A) p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz
Weight 92 kg p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 50 Hz
Voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Current 19.6 UU / 9.8 Y A p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Power at pump shaft 5.3 kW p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Vacuum -360 mbar p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Pressure 290 mbar p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Sound pressure level 69 dB(A) p.2 ↗ 2BH20360-2AAKL1-BA, stage 1, 60 Hz
Voltage 190-210 V p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz, D
Current 46.4 A p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz, D
Power at pump shaft 12.6 kW p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz
Vacuum -530 mbar p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz
Pressure 870 mbar p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz
Weight 130 kg p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 50 Hz
Voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 60 Hz
Current 52.8 UU / 26.4 Y A p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 60 Hz
Power at pump shaft 14.5 kW p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 60 Hz
Vacuum -580 mbar p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 60 Hz
Pressure 930 mbar p.2 ↗ 2BH20360-2AAKP1-BA, stage 4, 60 Hz

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series: side channel blower
5-8 p.2 ↗ 0360 Size
9-10 p.2 ↗ -2 Performance stage 1-4
11-13 p.2 ↗ AAK Voltage variant: AAK = 190-210 V D / 190-210 UU / 380-420 U
11-13 p.2 ↗ AAQ Voltage variant: AAQ = 380-420 V D / 660-725 U / 440-480 D / 460 D

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH20360-2AAKL1-BA p.2 ↗ 2BH20360-2AAKL1-BA stage 1, 50/60 Hz, 190-210 V D / 190-210 UU / 380-420 U IE3, 92 kg
2BH20360-2AAKM1-BA p.2 ↗ 2BH20360-2AAKM1-BA stage 2, 50/60 Hz, 190-210 V D / 190-210 UU / 380-420 U IE3, 99 kg
2BH20360-2AAKN1-BA p.2 ↗ 2BH20360-2AAKN1-BA stage 3, 50/60 Hz, 190-210 V D / 190-210 UU / 380-420 U IE3, 111 kg
2BH20360-2AAKP1-BA p.2 ↗ 2BH20360-2AAKP1-BA stage 4, 50/60 Hz, 190-210 V D / 190-210 UU / 380-420 U IE3, 130 kg
2BH20360-2AAKL6-BA p.2 ↗ 2BH20360-2AAKL6-BA stage 1, 50/60 Hz, 220-240 V D / 380-420 U / 440-480 U / 460 U IE3, 92 kg
2BH20360-2AAKM6-BA p.2 ↗ 2BH20360-2AAKM6-BA stage 2, 50/60 Hz, 220-240 V D / 380-420 U / 440-480 U / 460 U IE3, 99 kg
2BH20360-2AAKN6-BA p.2 ↗ 2BH20360-2AAKN6-BA stage 3, 50/60 Hz, 220-240 V D / 380-420 U / 440-480 U / 460 U IE3, 111 kg
2BH20360-2AAKP6-BA p.2 ↗ 2BH20360-2AAKP6-BA stage 4, 50/60 Hz, 220-240 V D / 380-420 U / 440-480 U / 460 U IE3, 130 kg
2BH20360-2AAQL7-BA p.2 ↗ 2BH20360-2AAQL7-BA stage 1, 50/60 Hz, 380-420 V D / 660-725 U / 440-480 D / 460 D IE3, 92 kg
2BH20360-2AAQM7-BA p.2 ↗ 2BH20360-2AAQM7-BA stage 2, 50/60 Hz, 380-420 V D / 660-725 U / 440-480 D / 460 D IE3, 99 kg