Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH2 2BH20540-2 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Technical data sheet 2BH2 0540-2: VELOCIS G-BH2 e side channel blower with integrated frequency converter (VFD), 2BH20540-2 series; covers 85 Hz / 380 V Y and 400 V Δ operation, 37/50/60 Hz VFD points, VFD types 2FC4xxx-1 and I/O automation options Z=U51…U54.

Technical Data

Parameter Value Condition
Rated frequency 85 Hz p.2 ↗ 2BH20540-2AA3P6-BA, 380 V Y
Rated voltage 380 V p.2 ↗ 2BH20540-2AA3P6-BA, Y connection
Rated current 41.0 A p.2 ↗ 2BH20540-2AA3P6-BA, 380 V Y
Rated power 20.5 kW p.2 ↗ 2BH20540-2AA3P6-BA, 380 V Y
Max. differential pressure vacuum -510 mbar p.2 ↗ 2BH20540-2AA3P6-BA, 85 Hz
Max. differential pressure pressure 370 mbar p.2 ↗ 2BH20540-2AA3P6-BA, 85 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH20540-2AA3P6-BA, 85 Hz
Weight 176 kg p.2 ↗ 2BH20540-2AA3P6-BA
Rated current 48.0 A p.2 ↗ 2BH20540-2AA3Q6-BA, 380 V Y
Rated power 25.0 kW p.2 ↗ 2BH20540-2AA3Q6-BA, 380 V Y
Max. differential pressure pressure 600 mbar p.2 ↗ 2BH20540-2AA3Q6-BA, 85 Hz
Weight 186 kg p.2 ↗ 2BH20540-2AA3Q6-BA
Rated current 26.0 A p.2 ↗ 400 V Δ, 85 Hz
Rated power 14.0 kW p.2 ↗ 400 V Δ, 85 Hz
Max. differential pressure vacuum -160 mbar p.2 ↗ 400 V Δ, 85 Hz
Max. differential pressure pressure 80 mbar p.2 ↗ 400 V Δ, 85 Hz
Rated current 39.5 A p.2 ↗ 400 V Δ, 85 Hz, variant J
Rated power 20.5 kW p.2 ↗ 400 V Δ, 85 Hz, variant J
Max. differential pressure pressure 370 mbar p.2 ↗ 400 V Δ, 85 Hz, variant J
Rated current 53.7 A p.2 ↗ 400 V, 85 Hz
Rated power 28.2 kW p.2 ↗ 400 V, 85 Hz
Max. differential pressure pressure 800 mbar p.2 ↗ 400 V, 85 Hz
Rated voltage / frequency set point 345 V / 87 Hz V / Hz p.1 ↗ frequency converter operation, delta connection
Minimum pulse frequency 4 kHz p.1 ↗ frequency converter operation
Minimum mains voltage for frequency converter 380 V p.1 ↗ frequency converter operation

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series: side channel blower G-BH2 e
5-8 p.2 ↗ 0540 Size 0540
9-10 p.2 ↗ -2 Version / stage
field 1 p.2 ↗ AA3P6 / AA3Q6 / AAKP6 Motor / voltage / frequency variant code
field 2 p.2 ↗ BA Design variant
VFD type field p.2 ↗ 2FC4xxx-1 □ □00 Frequency converter type; placeholders encode converter size and options