Technical Data Sheet — 2BH20540-2 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH2 0540-2: side channel blower with IE3 motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (E225239). Covers three sizes (No. 1, 2, 3) with several voltage/frequency variants and IE3 or NP motor efficiency variants.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 50 Hz p.2 ↗ | 2BH2 0540-2, size 1, 190-210 Δ |
| Voltage | 190-210 Δ V p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Current | 30.8 Δ A p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Power | 8.6 kW p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Max. differential pressure vacuum | -530 mbar p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Max. differential pressure pressure | 450 mbar p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Sound pressure level | 70 dB(A) p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Weight approx. | 132 kg p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Efficiency | IE3 p.2 ↗ | 2BH2 0540-2, size 1, 50 Hz |
| Rated frequency | 60 Hz p.2 ↗ | 2BH2 0540-2, size 1, 190-210 ΥΥ / 380-420 Υ |
| Voltage | 190-210 ΥΥ / 380-420 Υ V p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Current | 35.2 ΥΥ / 17.6 A p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Power | 9.9 kW p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Max. differential pressure vacuum | -460 mbar p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Max. differential pressure pressure | 350 mbar p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Weight approx. | 132 kg p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Efficiency | IE3 p.2 ↗ | 2BH2 0540-2, size 1, 60 Hz |
| Power | 12.6 kW p.2 ↗ | 2BH2 0540-2, size 2, 50 Hz |
| Power | 17.3 kW p.2 ↗ | 2BH2 0540-2, size 3, 50 Hz |
| Protection category | IP55 p.2 ↗ | all variants |
| Insulation class | F p.2 ↗ | all variants |
Operating Limits
- Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure: 1013 mbar p.1 ↗
- Protection category: IP55 p.1 ↗
- Insulation class: F p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH2 | Series: side channel blower G-BH2 |
| 5-8 p.2 ↗ | 0540 | Size designation (2BH2 0540-2) |
| 9-10 p.2 ↗ | -2 | Version / stage number |
| 11-12 p.2 ↗ | AA | Motor / design variant |
| 16-18 p.2 ↗ | -BA | Suffix / variant |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH20540-2AAKN1-BA p.2 ↗ | 2BH20540-2AAKN1-BA | size 1, 50/60 Hz, 190-210 Δ / 190-210 ΥΥ / 380-420 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAKP1-BA p.2 ↗ | 2BH20540-2AAKP1-BA | size 2, 50/60 Hz, 190-210 Δ / 190-210 ΥΥ / 380-420 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAKQ1-BA p.2 ↗ | 2BH20540-2AAKQ1-BA | size 3, 50/60 Hz, 190-210 Δ / 190-210 ΥΥ / 380-420 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAKN6-BA p.2 ↗ | 2BH20540-2AAKN6-BA | size 1, 50/60 Hz, 220-240 Δ / 380-420 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAKQ6-BA p.2 ↗ | 2BH20540-2AAKQ6-BA | size 3, 50/60 Hz, 220-240 ΥΥ / 440-480 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAQQ3-BA p.2 ↗ | 2BH20540-2AAQQ3-BA | size 3, 50/60 Hz, 475-525 Υ / 550-600 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAQN7-BA p.2 ↗ | 2BH20540-2AAQN7-BA | size 1, 50/60 Hz, 380-420 Δ / 660-725 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAQP7-BA p.2 ↗ | 2BH20540-2AAQP7-BA | size 2, 50/60 Hz, 380-420 Δ / 660-725 Υ, IE3 | Order No. as printed | |
| 2BH20540-2AAQQ7-BA p.2 ↗ | 2BH20540-2AAQQ7-BA | size 3, 50/60 Hz, 380-420 Δ / 660-725 Υ, IE3 | Order No. as printed | |