Data sheet 2BH2 0540-3: side channel blower with IE3-motors, 3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CAN/CSA C22.2 No. 68-09 (E225239). Covers sizes 180, 190, 202 with voltage variants (190-210/380-420 V, 220-240/440-480 V, 475-525/550-600 V, 380-420/660-725 V, 440-480/460 V) and IE3/NP motor variants.

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ size 180, 50 Hz, Δ
Rated current 46.4 A p.2 ↗ size 180, 50 Hz, Δ
Motor power 12.6 kW p.2 ↗ size 180, 50 Hz
Vacuum -610 mbar p.2 ↗ size 180, 50 Hz
Pressure 640 mbar p.2 ↗ size 180, 50 Hz
Sound pressure level 70 dB(A) p.2 ↗ size 180, 50 Hz
Weight 180 kg p.2 ↗ size 180, 50 Hz
Rated voltage 190-210 ΥΥ / 380-420 Υ V p.2 ↗ size 180, 60 Hz
Rated current 52.8 ΥΥ / 26.4 A p.2 ↗ size 180, 60 Hz
Motor power 14.5 kW p.2 ↗ size 180, 60 Hz
Vacuum -590 mbar p.2 ↗ size 180, 60 Hz
Pressure 500 mbar p.2 ↗ size 180, 60 Hz
Sound pressure level 75 dB(A) p.2 ↗ size 180, 60 Hz
Motor power 17.3 kW p.2 ↗ size 190, 50 Hz
Vacuum -610 mbar p.2 ↗ size 190, 50 Hz
Pressure 980 mbar p.2 ↗ size 190, 50 Hz
Sound pressure level 70 dB(A) p.2 ↗ size 190, 50 Hz
Weight 190 kg p.2 ↗ size 190, 50 Hz
Motor power 21.3 kW p.2 ↗ size 202, 50 Hz
Vacuum -610 mbar p.2 ↗ size 202, 50 Hz
Pressure 1020 mbar p.2 ↗ size 202, 50 Hz
Sound pressure level 70 dB(A) p.2 ↗ size 202, 50 Hz
Weight 202 kg p.2 ↗ size 202, 50 Hz
Protection class IP55 p.2 ↗
Insulation class F p.2 ↗

Operating Limits

  • Max ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance tolerance: ± 10 % p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series: side channel blower
5-8 p.2 ↗ 0540 Size designation
9-10 p.2 ↗ -3 Version / generation
11-13 p.2 ↗ AAK / AAQ Voltage variant group
16-17 p.2 ↗ -BA Motor variant suffix (IE3/NP)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH20540-3AAKP1-BA p.2 ↗ 2BH20540-3AAKP1-BA size 180, 50/60 Hz, 190-210/380-420 V, IE3
2BH20540-3AAKQ1-BA p.2 ↗ 2BH20540-3AAKQ1-BA size 190, 50/60 Hz, 190-210/380-420 V, IE3
2BH20540-3AAKR1-BA p.2 ↗ 2BH20540-3AAKR1-BA size 202, 50/60 Hz, 190-210/380-420 V, IE3
2BH20540-3AAKP6-BA p.2 ↗ 2BH20540-3AAKP6-BA size 180, 50/60 Hz, 220-240/440-480 V, IE3
2BH20540-3AAKQ6-BA p.2 ↗ 2BH20540-3AAKQ6-BA size 190, 50/60 Hz, 220-240/440-480 V, IE3
2BH20540-3AAKR6-BA p.2 ↗ 2BH20540-3AAKR6-BA size 202, 50/60 Hz, 220-240/440-480 V, IE3
2BH20540-3AAQP7-BA p.2 ↗ 2BH20540-3AAQP7-BA size 180, 50/60 Hz, 380-420/660-725 V, IE3
2BH20540-3AAQQ7-BA p.2 ↗ 2BH20540-3AAQQ7-BA size 190, 50/60 Hz, 380-420/660-725 V, IE3
2BH20540-3AAQR7-BA p.2 ↗ 2BH20540-3AAQR7-BA size 202, 50/60 Hz, 380-420/660-725 V, IE3
2BH20540-3AAQR3-BA p.2 ↗ 2BH20540-3AAQR3-BA size 202, 50/60 Hz, 475-525/550-600 V, NP