Technical Data Sheet — L-BV2 compressor (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BV2 060, liquid ring compressor of the L-BV2 family, size 2BV2 060. Variants: cast iron (standard, RAL 9006) or stainless steel; material code variants N, M, P, H, C; voltage/frequency variants K1, K6, Q02-3B, Q02-7B; ATEX category 2G versions available.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Suction capacity | 0,20 m3/h p.2 ↗ | 2BV2 060, 50 Hz |
| Rated power | 1,75 kW p.2 ↗ | 2BV2 060, 50 Hz |
| Rated power | 2,0 kW p.2 ↗ | 2BV2 060, 60 Hz |
| Service factor | 1,00 SF p.2 ↗ | 2BV2 060 |
| Efficiency class | IE3 - p.2 ↗ | 2BV2 060, 50 Hz |
| Efficiency class | NP - p.2 ↗ | 2BV2 060, 60 Hz |
| Quantity of operating liquid | 0,20 m3/h p.2 ↗ | 2BV2 060 |
| Sound pressure level | 62 dB(A) p.2 ↗ | 2BV2 060, 50 Hz |
| Sound pressure level | 65 dB(A) p.2 ↗ | 2BV2 060, 60 Hz |
| Weight | 28 kg p.2 ↗ | 2BV2 060 |
| Voltage | 190-210 V p.2 ↗ | 2BV2 060, 50 Hz, K1, delta |
| Voltage | 190-210 / 380-420 V p.2 ↗ | 2BV2 060, 50 Hz, K1, YY/delta |
| Voltage | 220-240 / 380-420 V p.2 ↗ | 2BV2 060, 50 Hz, K6, delta/delta |
| Voltage | 220-240 / 440-480 V p.2 ↗ | 2BV2 060, 60 Hz, K6, YY/delta |
| Voltage | 500 V p.2 ↗ | 2BV2 060, 50 Hz, Q02-3B, delta |
| Voltage | 575 V p.2 ↗ | 2BV2 060, 60 Hz, Q02-3B, delta |
| Voltage | 380-420 / 660-725 V p.2 ↗ | 2BV2 060, 50 Hz, Q02-7B, delta/delta |
| Voltage | 440-480 V p.2 ↗ | 2BV2 060, 60 Hz, Q02-7B, delta |
| Current | 6,9 A p.2 ↗ | 2BV2 060, 50 Hz, 190-210 V delta |
| Current | 7,8 / 3,9 A p.2 ↗ | 2BV2 060, 50 Hz, 190-210 V YY / 380-420 V delta |
| Current | 6,0 / 3,45 A p.2 ↗ | 2BV2 060, 50 Hz, 220-240 V delta / 380-420 V delta |
| Current | 6,8 / 3,4 A p.2 ↗ | 2BV2 060, 60 Hz, 220-240 V YY / 440-480 V delta |
| Current | 2,76 A p.2 ↗ | 2BV2 060, 50 Hz, 500 V delta |
| Current | 2,72 A p.2 ↗ | 2BV2 060, 60 Hz, 575 V delta |
| Protection rating | IP55 - p.2 ↗ | 2BV2 060 |
Operating Limits
- Protection rating: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- ATEX category available: 2G p.1 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Operating liquid temperature for characteristic curves: 15 °C p.1 ↗
- Characteristic curve tolerance: ± 10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BV2 | Product family: liquid ring compressor L-BV2 |
| 5-7 p.2 ↗ | 060 | Size designation |
| material field p.3 ↗ | N | Material variant: cast iron casing with ceramic coating, bronze impeller, cast iron lantern |
| material field p.3 ↗ | M | Material variant: CrNi steel casing, CrNi steel impeller, CrNi steel lantern |
| material field p.3 ↗ | P | Material variant: CrNi steel casing, CrNi steel impeller, CrNi steel lantern (alternative seal) |
| material field p.3 ↗ | H | Material variant: cast chrome-nickel-molybdenum steel components |
| material field p.3 ↗ | C | Material variant: cast iron casing with ceramic coating, cast chrome-nickel-molybdenum steel impeller |
| voltage field p.2 ↗ | K1 | Voltage variant: 50 Hz 190-210 V delta / 190-210 V YY, 220-240 V delta / 380-420 V YY; 60 Hz 200 V YY / 230 V delta / 400 V Y |
| voltage field p.2 ↗ | K6 | Voltage variant: 50 Hz 190-210 V YY / 220-240 V delta / 380-420 V Y; 60 Hz 220-240 V YY / 440-480 V Y |
| voltage field p.2 ↗ | Q02-3B | Voltage variant: 50 Hz 500 V delta; 60 Hz 575 V delta |
| voltage field p.2 ↗ | Q02-7B | Voltage variant: 50 Hz 380-420 V delta / 660-725 V delta; 60 Hz 440-480 V delta |