Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV5 2BV5131 IE3 (DE)

Technical Reference Summary

Covered Models & Document Scope

Technical datasheet for liquid ring vacuum pump type 2BV5 131, ATEX 3~ 50 Hz design, protection IP55, insulation class F. Variants: material K* (cast iron, ceramic-coated interior) and H** (stainless steel); ATEX category 2G (F91 cast iron version: II 2G Ex h IIB T3 Gb, motor 0158 II 2G Ex eb IIC T3 G); voltage variants 400 D / 690 Y and 500 D at 50 Hz, plus other voltages for 50/60 Hz.

Technical Data

Parameter Value Condition
Frequency 50 Hz p.2 ↗ 2BV5131, 400 D / 690 Y
Voltage 400 D / 690 Y V p.2 ↗ 2BV5131, 50 Hz
Current 26,0 D / 15,1 Y A p.2 ↗ 2BV5131, 400 D / 690 Y, 50 Hz
Motor power 10,5 kW p.2 ↗ 2BV5131, 50 Hz
Service factor 1,29 - p.2 ↗ 2BV5131, 50 Hz
Efficiency class IE3 - p.2 ↗ 2BV5131, 50 Hz
Operating liquid quantity 1,8 m³/h p.2 ↗ 2BV5131, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BV5131, 50 Hz, EN ISO 3744, 1 m, tolerance ±3 dB(A)
Weight 216* / 219** kg p.2 ↗ 2BV5131, 50 Hz; * material K, ** material H
Voltage 500 D V p.2 ↗ 2BV5131, 50 Hz
Current 21,0 D A p.2 ↗ 2BV5131, 500 D, 50 Hz
Motor power 10,5 kW p.2 ↗ 2BV5131, 500 D, 50 Hz
Service factor 1,29 - p.2 ↗ 2BV5131, 500 D, 50 Hz
Operating liquid quantity 1,8 m³/h p.2 ↗ 2BV5131, 500 D, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BV5131, 500 D, 50 Hz
Weight 216* / 219** kg p.2 ↗ 2BV5131, 500 D, 50 Hz; * material K, ** material H
Operating liquid quantity at p1 >500 mbar abs., fresh water 15°C 0,4 / 0,4 m³/h p.2 ↗ 50 Hz / 60 Hz
Operating liquid quantity at p1 200-500 mbar abs., fresh water 15°C 0,45 / 0,45 m³/h p.2 ↗ 50 Hz / 60 Hz
Operating liquid quantity at p1 <200 mbar abs., fresh water 15°C 1,8 / 1,8 m³/h p.2 ↗ 50 Hz / 60 Hz
Max. additional water carry-over 4,50 m³/h p.2 ↗ 50 Hz
Max. back pressure 1300 mbar abs. p.2 ↗ 50 Hz
Max. additional water carry-over 4,50 m³/h p.2 ↗ 60 Hz
Max. back pressure 1300 mbar abs. p.2 ↗ 60 Hz
Protection rating IP55 - p.2 ↗ 2BV5131
Insulation class F - p.2 ↗ 2BV5131

Operating Limits

  • Frequency tolerance: max. ±2 % p.2 ↗
  • Max. additional water carry-over: 4,50 m³/h p.2 ↗
  • Max. back pressure: 1300 mbar abs. p.2 ↗
  • Protection rating: IP55 p.2 ↗
  • Insulation class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BV5131 Type / size designation (2BV5 series, size 131)
field 1 p.2 ↗ 0 Design variant
field 2 p.2 ↗ D02 Voltage / connection variant code (D02 for 400 D / 690 Y or 500 D)
field 3 p.2 ↗ 6B / 5B Voltage code: 6B = 400 D / 690 Y, 5B = 500 D
field 4 p.2 ↗ Z Option field, substituted by Z= value
voltage field (other voltages) p.2 ↗ D Voltage code for 400 D / 690 Y, 230 D / 400 Y or 500 D
voltage field (other voltages) p.2 ↗ G Voltage code for 460 Y, 575 D or 460 D