Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV5 2BV5131 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BV5 131: liquid ring vacuum pump in ATEX configuration (2014/34 EU, category 2G). Variants: material K (cast iron casing with ceramic-coated internal surface, bronze impeller) and material H (CrNi steel). 50 Hz and 60 Hz, IP55, insulation class F, IE3.

Technical Data

Parameter Value Condition
Ultimate inlet pressure 33 mbar abs. p.1 ↗ 97 % vacuum
Cavitation-free operation down to 80 mbar abs. p.1 ↗
Frequency 50 Hz p.2 ↗ 2BV5131, 400 D / 690 Y
Voltage 400 D / 690 Y V p.2 ↗ 2BV5131, 50 Hz
Current 26,0 D / 15,1 Y A p.2 ↗ 2BV5131, 50 Hz, 400 D / 690 Y
Motor power 14,1 hp p.2 ↗ 2BV5131, 50 Hz
Service factor 1,29 p.2 ↗ 2BV5131, 50 Hz
Efficiency class IE3 p.2 ↗ 2BV5131, 50 Hz
Quantity of operating liquid 1,1 m³/h p.2 ↗ 2BV5131, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BV5131, 50 Hz
Weight 476* / 483** lbs p.2 ↗ 2BV5131, 50 Hz; * material K, ** material H
Frequency 50 Hz p.2 ↗ 2BV5131, 500 D
Voltage 500 D V p.2 ↗ 2BV5131, 50 Hz
Current 21,0 D A p.2 ↗ 2BV5131, 50 Hz, 500 D
Motor power 14,1 hp p.2 ↗ 2BV5131, 50 Hz, 500 D
Service factor 1,29 p.2 ↗ 2BV5131, 50 Hz, 500 D
Efficiency class IE3 p.2 ↗ 2BV5131, 50 Hz, 500 D
Quantity of operating liquid 1,1 m³/h p.2 ↗ 2BV5131, 50 Hz, 500 D
Sound pressure level 73 dB(A) p.2 ↗ 2BV5131, 50 Hz, 500 D
Weight 476* / 483** lbs p.2 ↗ 2BV5131, 50 Hz, 500 D; * material K, ** material H
Protection rating IP55 p.2 ↗ ATEX 3~ 50 Hz version
Insulation material class F p.2 ↗ ATEX 3~ 50 Hz version
ATEX category II 2G Ex h IIB T3 Gb p.2 ↗ material K (cast iron); motor: 0158 II 2G Ex eb IIC T3 Gb
ATEX category II 2G Ex h IIC T3 Gb p.2 ↗ material H (stainless steel); motor: 0158 II 2G Ex eb IIC T3 Gb

Operating Limits

  • Minimum inlet pressure: 33 mbar abs. (97 % vacuum) p.1 ↗
  • Cavitation-free operation down to: 80 mbar abs. p.1 ↗
  • Protection rating: IP55 p.1 ↗
  • ATEX temperature class inside pump: T4 p.1 ↗
  • ATEX ambient conditions: T3 p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BV5131 Type / model range L-BV5, size 131
10-12 p.2 ↗ D02 Motor / connection variant