Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV5 2BV5161 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

L-BV5 liquid ring vacuum pump with ejector, data sheet 2BV5 161. Covers 50 Hz and 60 Hz operation, voltage variants 230Δ/400Y, 265Δ/460Y, 400Δ/690Y, 460Δ, 500Δ, 575Δ, and material variants K (cast iron casing with ceramic coating, bronze port plate) and H (CrNi steel casing, port plate and impeller).

Technical Data

Parameter Value Condition
Suction capacity 300 m³/h p.2 ↗ 2BV5 161, 50 Hz, material K
Suction capacity 304 m³/h p.2 ↗ 2BV5 161, 60 Hz, material H
Rated voltage 230 ∆/ 400 Y V p.2 ↗ 50 Hz
Rated voltage 265 ∆/ 460 Y V p.2 ↗ 60 Hz
Rated voltage 400 ∆/ 690 Y V p.2 ↗ 50 Hz
Rated voltage 460 ∆ V p.2 ↗ 60 Hz
Rated voltage 500 ∆ V p.2 ↗ 50 Hz
Rated voltage 575 ∆ V p.2 ↗ 60 Hz
Current 51,0 ∆ / 29,5 Y A p.2 ↗ 50 Hz, 230∆/400Y
Current ∆/ 28 Y A p.2 ↗ 60 Hz, 265∆/460Y
Current 29,5 ∆ / 17 Y A p.2 ↗ 50 Hz, 400∆/690Y
Current 28,0 ∆ A p.2 ↗ 60 Hz, 460∆
Current 23,5 ∆ A p.2 ↗ 50 Hz, 500∆
Current 22,5 ∆ A p.2 ↗ 60 Hz, 575∆
Power 12,40 kW p.2 ↗ 50 Hz
Power 16,00 kW p.2 ↗ 60 Hz
Service factor 1,21 p.2 ↗ 50 Hz
Service factor 1,03 p.2 ↗ 60 Hz
Operation liquid quantity 2,40 m³/h p.2 ↗ 50 Hz / 60 Hz
Sound pressure level 74 dB(A) p.2 ↗ 50 Hz
Sound pressure level 75 dB(A) p.2 ↗ 60 Hz
Weight 300 kg p.2 ↗ material K
Weight 304 kg p.2 ↗ material H
Max. water carry-over 6 m³/h p.2 ↗ 50 Hz and 60 Hz
Back pressure 1300 mbar atm. p.2 ↗ 50 Hz and 60 Hz

Operating Limits

  • Ultimate pressure (inlet pressure): 33 mbar abs. p.1 ↗
  • Cavitation-free operation down to: 80 mbar abs. p.1 ↗
  • Protection category: IP55 p.1 ↗
  • Max. back pressure: 1300 mbar atm. p.2 ↗
  • Max. water carry-over: 6 m³/h p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BV5161 Model range L-BV5, size 161
field 1 p.2 ↗ 0 Design variant
field 2 p.2 ↗ Q Voltage code (Q = standard voltage range)
field 3 p.2 ↗ 1, 5, 6, 7 Voltage variant: 1 = 200-240V∆/310-415VY (50 Hz) / 200-275V∆/350-480VY (60 Hz); 5 = 450-550V∆ (50 Hz) / 520-600V∆ (60 Hz); 6 = 200-260V∆/350-450VY (50 Hz) / 230-290V∆/400-500VY (60 Hz); 7 = 350-450V∆/610-725VY (50 Hz) / 400-500V∆/690-725VY
suffix p.2 ↗ K Material variant: cast iron casing with ceramic coating, bronze port plate
suffix p.2 ↗ H Material variant: CrNi steel casing, port plate and impeller