Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BV5 2BV5161 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BV5 161: liquid ring vacuum pump in ATEX configuration, model range L-BV5, size 2BV5161. Variants: cast iron (material K, internal surface with ceramic) and stainless steel (material H, CrNi steel); ATEX category 2G, temperature class T4 inside pump / T3 ambient; 50 Hz and 60 Hz; voltages 400 D / 690 Y, 500 D, 575 D.

Technical Data

Parameter Value Condition
Ultimate pressure 33 mbar abs. p.1 ↗ 97 % vacuum
Cavitation-free operation down to 80 mbar abs. p.1 ↗
Pumping speed 765 m³/h p.2 ↗ 2BV5161, 50 Hz, cast iron (K*)
Pumping speed 772 m³/h p.2 ↗ 2BV5161, 50 Hz, stainless steel (H**)
Voltage 400 D / 690 Y V p.2 ↗ 2BV5161, 50 Hz
Voltage 500 D V p.2 ↗ 2BV5161, 50 Hz
Current 28,0 D / 16,2 Y A p.2 ↗ 2BV5161, 50 Hz, 400 D / 690 Y
Current 22,5 D A p.2 ↗ 2BV5161, 50 Hz, 500 D
Motor power 16,6 hp p.2 ↗ 2BV5161, 50 Hz
Efficiency class IE3 p.2 ↗ 2BV5161, 50 Hz
Service factor 1,06 p.2 ↗ 2BV5161, 50 Hz
Rated service factor 1,4 p.2 ↗ 2BV5161, 50 Hz
Noise level 74 dB(A) p.2 ↗ 2BV5161, 50 Hz
Weight 765* 772** lbs p.2 ↗ 2BV5161, 50 Hz, *cast iron / **stainless steel
Protection rating IP55 p.1 ↗ standard motor
Operating liquid quantity 0,3 / 0,3 m³/h p.2 ↗ 50 Hz / 60 Hz, fresh water, p1 >14,8 inch Hg
Operating liquid quantity 0,41 / 0,41 m³/h p.2 ↗ 50 Hz / 60 Hz, fresh water, p1 5,9-14,8 inch Hg
Operating liquid quantity 1,42 / 1,42 m³/h p.2 ↗ 50 Hz / 60 Hz, fresh water, p1 <5,9 inch Hg
Water carry-over 0,18 cfm p.2 ↗ 50 Hz
Water carry-over 0,18 cfm p.2 ↗ 60 Hz
Back pressure 770 inch Hg p.2 ↗ 50 Hz and 60 Hz

Operating Limits

  • Max ambient temperature class: T3 p.1 ↗
  • Temperature class inside pump: T4 p.1 ↗
  • ATEX category: 2G p.1 ↗
  • Minimum inlet pressure without cavitation protection: 80 mbar abs. p.1 ↗
  • Minimum inlet pressure with gas ejector: 10 mbar abs. p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BV5161 Type / model range L-BV5, size 161
field 1 p.2 ↗ □ Material variant: K = cast iron (internal surface with ceramic), H = CrNi steel
field 2 p.2 ↗ □ Voltage connection: D = delta, Y = star (50 Hz: 400 D / 690 Y, 500 D; 60 Hz: 500 D, 575 D)