The Agilent diffusion pump line is represented here only by a roll-to-roll web-coating technical overview, not by pump specifications. The verified data describe a deposition process: 1660 mm maximum deposited-layer web width, 1300 mm for electrolytic Cu/Al foil, and 650 mm for rolled Al foil. No pump geometry, speed, or fluid data are available.
Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection
| Model | Motor power, kW | Base pressure, mbar | Diffusion pump pumping speed, L/s | Maximim width, mm | Maximum web width deposited layer, mm | Maximum web width electrolytic foil cu al, mm |
|---|---|---|---|---|---|---|
| Diffusion Pumps, Current | — | — | 50000 | 650 | 1660 | 1300 |
| Helium Leak Detectors for Vacuum & Sniffing Applications | — | — | 50000 | 650 | 1660 | 1300 |
| Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps | 0.119 | 3.3 | — | — | — | — |
| Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations | — | 10 | — | — | — | — |
| Vacuum Components - Flanges, Fittings, Valves, & Greases | — | — | — | — | — | — |
Full specifications
| Diffusion Pump Pumping Speed | 50000 L/s |
| Thickness | 6...100 µm |
| Substrate thickness (rolled foil, Al) mfr | 6...100 μm |
| Substrate thickness (electrolytic foil, Cu/Al) mfr | 5...140 μm |
| Substrate thickness mfr | 50 μm |
| unwind zone pressure mfr | 10...1 mbar |
| turbomolecular pump pumping speed mfr | 70...2,000 L/s |
| bulk metal foil thickness mfr | 4...10 μm |
| replacement film thickness mfr | 1 μm |
| automotive energy density requirement mfr | 400 Wh/kg |
| energy density increase mfr | 20 |
| CO2 emission reduction mfr | 20 |
| Maximim Width | 650 mm |
| Maximum Web Width (deposited Layer) | 1660 mm |
| Maximum Web Width (electrolytic Foil, Cu/al) | 1300 mm |
| Maximum Web Width (rolled Foil, Al) | 650 mm |
| anode/cathode collector weight reduction mfr | 50...60 |
| battery weight reduction mfr | 15 |
| Coating thickness (deposited layer) mfr | 50 μm |
Description
What the verified facts actually cover
- The matched specs are web-coating dimensions, not diffusion-pump ratings: maximum deposited-layer web width 1660 mm, electrolytic foil (Cu/Al) 1300 mm, rolled Al foil 650 mm.
- Substrate thickness ranges: rolled Al foil 6–100 µm; electrolytic Cu/Al foil 5–140 µm; deposited coating thickness 50 µm.
- The only attached document is a technical overview of roll-to-roll metal deposition for lithium-ion battery production; it contains no pump models, sizes, or ordering codes.
Positioning inside the series
- Sibling entries are other vacuum product families (helium leak detectors, Roots pumping systems, dry scroll pumps, turbo pumping systems). No sibling diffusion-pump variant is listed, so no modification-to-modification comparison can be made from the verified facts.
- Because the model_code field reads only 'Diffusion Pumps,' the exact pump size, stages, and fluid cannot be stated.
Behavior and operation
- No curve points, no pumping-speed table, no pressure ranges, and no manual sections were supplied. Behavior under load, backing-pump requirements, and fluid/boiler data are therefore not described here rather than inferred.
Integration & Operating Notes
The allowable web width is not a single number: 1660 mm applies to the deposited layer, 1300 mm to electrolytic Cu/Al foil, and 650 mm to rolled Al foil. Line layout and roll-handling hardware must be sized to the narrowest relevant case for the foil actually run.
Rolled Al foil is specified at 6–100 µm and electrolytic Cu/Al foil at 5–140 µm, with a 50 µm deposited layer. Tension and transport settings must be validated per foil type; the two ranges are not interchangeable on one setup without re-checking web handling.
The attached document is a process overview of roll-to-roll metal deposition and contains no maintenance intervals, fluid-change schedules, or error codes. Service planning for the diffusion pump itself must come from the pump manual, which is not part of the verified facts.
Selection & Integration Q&A
The verified facts do not contain diffusion-pump performance data, so a defensible choice against scroll or turbo systems cannot be made from this card. The only process data supplied concern roll-to-roll web deposition widths (1660/1300/650 mm) and foil thicknesses, not pump speed or pressure.
The supplied facts give web widths and foil thicknesses only; they do not state inlet flange size, backing-pump requirements, or fluid type. Those must be taken from the pump manual, which is not among the verified documents, before matching foreline and flange hardware.
No mounting orientation, ambient temperature, cooling-water, or duty-cycle limits appear in the verified facts. The attached document is a process overview without installation sections, so these limits must be confirmed from the pump manual before installation planning.
The verified facts list no maintenance intervals, consumables, cables, or included accessories, and no certificates. The only document is a roll-to-roll deposition overview with no service content, so fluid, heater, and seal spares must be defined from the pump manual.