Agilent Technologies Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps

Agilent Technologies Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h.

The Agilent IDP-series dry scroll pump is an oil-free, quiet vacuum source with a 60 L/min pumping speed and 3.3 mbar base pressure, driven by a 0.16 HP motor. It is a compact roughing pump for oil-sensitive analytical and laboratory vacuum systems.

Motor power
0.119 kW
Pumping speed
3.6 m³/h

Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection

Model Motor power, kWBase pressure, mbarDiffusion pump pumping speed, L/sMaximim width, mmMaximum web width deposited layer, mmMaximum web width electrolytic foil cu al, mm
Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps Current 0.1193.3————
Diffusion Pumps, ——5000065016601300
Helium Leak Detectors for Vacuum & Sniffing Applications ——5000065016601300
Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations —10————
Vacuum Components - Flanges, Fittings, Valves, & Greases ——————

Full specifications

Core Performance & Functional Specifications
Motor power 0.16 HP
Pumping speed 60 L/min
Base Pressure 3.3 mbar
IDP-10 mfr 3810
IDP-10 with inlet isolation valve mfr 3810
IDP-7/10 tip seal replacement kit mfr 3807
Exhaust silencer kit mfr 110
Purge kit mfr 3807
Gas ballast kit mfr 3807
Inlet trap mfr 25
Vibration isolation kit mfr 110 VIBISOKIT
IDP-35 mfr 3835
IDP-35 with Gauge mfr 3835
IDP-35 with Inlet Valve mfr 3835
IDP-35 with Inlet Valve and Gauge mfr 3835
Inlet HEPA filter, NW40 mfr 40
HEPA filter, NW25 mfr 25
IDP-45 mfr 3845
IDP-45 with Gauge mfr 3845
IDP-45 with Inlet Valve mfr 3845
IDP-45 with Inlet Valve and Gauge mfr 3845
IDP-15 mfr 3815
IDP-15 with inlet isolation valve mfr 3815
IDP-15 tip seal replacement kit mfr 3815
IDP-3 mfr Vibration isolation kit kit
IDP-4 mfr Replacement filter element element
IDP-7 mfr Vibration isolation kit kit
inlet valve closing time mfr 20 milliseconds
inlet valve opening time after power restore mfr 10 seconds
tip seal replacement duration mfr half an hour hour
IDP-4 maintenance duration mfr 15...30 minutes
integrated Pirani gauge pressure range mfr -4...1000 mbar
VPI valve isolation time mfr 20 ms
Electrical, Power & Drive Specifications
Operating voltage mfr 100 VAC
IDP-35/IDP-45 supply frequency mfr 50 Hz

Description

Construction and series positioning

Performance and operating envelope

Drive, control and installation

Integration & Operating Notes

Electrical
Confirm mains voltage and frequency against the ordered variant

The family is offered with 100–120 VAC and 200–240 VAC motors plus a 24 VDC drive on the IDP-3, and with 50 Hz and 60 Hz operating points. Applying the wrong supply or frequency to the delivered unit can stall or damage the motor, so verify the nameplate before connection.

Agilent IDP dry scroll pump family brochure 5991-7583EN, scope and variants

Selection & Integration Q&A

When should I choose this dry scroll pump instead of a Roots, turbo or diffusion pump from the same catalogue?

Choose the scroll pump for oil-free roughing down to a 3.3 mbar base pressure at 60 L/min. Roots, turbo and diffusion pumps in the series cover higher pumping speeds or high-vacuum duty and are typically backed by a roughing pump such as this one.

What supply and backing-stage requirements must the surrounding system meet?

Match the motor variant to the site: 100–120 VAC or 200–240 VAC at the correct 50/60 Hz point, or 24 VDC on the IDP-3. As a backing pump it must be sized against the inlet flow of the high-vacuum stage it supports.

What mounting and duty-cycle limits apply from the manual?

The supplied document digests contain no mounting orientation, ambient temperature or duty-cycle data for this model. Consult the IDP instruction manual before installation; do not assume continuous-duty or any orientation without that confirmation.

What maintenance and accessories are needed beyond the base pump?

The base delivery details, cable set and controller options are not stated in the supplied digests. Tip-seal inspection follows the IDP manual schedule; confirm included accessories and any cabling or inlet fittings with the order documentation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent IDP-4 Dry Scroll Vacuum Pump
Brochure ·10,7 МБ ·11 pp.
View PDF