No photo available yet
Agilent Technologies Helium Leak Detectors for Vacuum & Sniffing Applications
Agilent Technologies Helium Leak Detectors for Vacuum & Sniffing Applications — Vacuum technologies.
Helium leak detectors configured for both vacuum-chamber testing and sniffing-mode leak location on roll-to-roll metal deposition lines. The matched web-width data (1660 mm deposited layer, 1300 mm Cu/Al electrolytic foil, 650 mm rolled Al foil) defines the coating-line envelope this detector serves, not a detector rating. Used to qualify vacuum integrity of R2R deposition chambers and locate leaks on the web path.
Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection
| Model | Motor power, kW | Base pressure, mbar | Diffusion pump pumping speed, L/s | Maximim width, mm | Maximum web width deposited layer, mm | Maximum web width electrolytic foil cu al, mm |
|---|---|---|---|---|---|---|
| Helium Leak Detectors for Vacuum & Sniffing Applications Current | — | — | 50000 | 650 | 1660 | 1300 |
| Diffusion Pumps, | — | — | 50000 | 650 | 1660 | 1300 |
| Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps | 0.119 | 3.3 | — | — | — | — |
| Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations | — | 10 | — | — | — | — |
| Vacuum Components - Flanges, Fittings, Valves, & Greases | — | — | — | — | — | — |
Full specifications
| Diffusion Pump Pumping Speed | 50000 L/s |
| Thickness | 6...100 µm |
| Substrate thickness (rolled foil, Al) mfr | 6...100 μm |
| Substrate thickness (electrolytic foil, Cu/Al) mfr | 5...140 μm |
| Substrate thickness mfr | 50 μm |
| unwind zone pressure mfr | 10...1 mbar |
| turbomolecular pump pumping speed mfr | 70...2,000 L/s |
| bulk metal foil thickness mfr | 4...10 μm |
| replacement film thickness mfr | 1 μm |
| automotive energy density requirement mfr | 400 Wh/kg |
| energy density increase mfr | 20 |
| CO2 emission reduction mfr | 20 |
| Maximim Width | 650 mm |
| Maximum Web Width (deposited Layer) | 1660 mm |
| Maximum Web Width (electrolytic Foil, Cu/al) | 1300 mm |
| Maximum Web Width (rolled Foil, Al) | 650 mm |
| anode/cathode collector weight reduction mfr | 50...60 |
| battery weight reduction mfr | 15 |
| Coating thickness (deposited layer) mfr | 50 μm |
Description
Positioning in the series
- This entry is a helium leak-detection configuration for vacuum and sniffing applications, not a pump; it sits alongside diffusion pumps, Roots systems, scroll pumps and turbo pumping stations in the Vacuum Technologies portfolio as the integrity-verification instrument for those pumping trains.
- The matched specifications describe the roll-to-roll deposition process it supports rather than the detector itself: maximum web width 1660 mm for the deposited layer, 1300 mm for electrolytic Cu/Al foil, 650 mm for rolled Al foil.
Process envelope served
- Substrate thickness ranges from 6 to 100 µm for rolled Al foil and 5 to 140 µm for electrolytic Cu/Al foil, with a deposited coating thickness of 50 µm. These are coating-line conditions the leak test must tolerate, not detector limits.
- No curve points, certificates or application notes were supplied for the detector itself, so no sensitivity, pumping-speed or response-time figures are asserted here.
Documentation scope
- The attached brochure is a corporate sustainability document covering the Lexington, Torino and Penang sites; it contains no model, size or ordering data.
- The roll-to-roll technical overview covers web deposition techniques and the role of vacuum and leak detection in lithium-ion battery production, again without model-specific data. Installation, control and connection specifics for this detector are therefore not available from the supplied documents.
Integration & Operating Notes
The 1660 mm deposited-layer, 1300 mm electrolytic-foil and 650 mm rolled-foil widths are maximum web widths of the roll-to-roll process this detector supports. They must not be read as detector dimensions or as limits on the leak-test connection; size the detector interface to the chamber port, not to web width.
Selection & Integration Q&A
The siblings are pumps that create vacuum; this unit verifies vacuum integrity by helium testing in both vacuum-chamber and sniffing modes. Pick it when the task is leak location or acceptance testing on the R2R deposition chamber, and pair it with the appropriate pump from the series rather than substituting one for the other.
The supplied documents give no flange, fitting or backing-pump data for this detector. Confirm the chamber test port size and the available backing vacuum from the installed pump (diffusion, Roots, scroll or turbo station) against the detector's own manual before ordering adapters; do not infer connection geometry from the web-width specifications.
No environmental or duty-cycle ratings are stated in the supplied documents. The process context is a 50 µm deposited layer on webs up to 1660 mm wide, with foil substrates from 5 to 140 µm; test scheduling must respect web handling of these thin substrates. Confirm ambient and cycle limits from the model manual.
The attached documents list no maintenance intervals, cables, probes or consumables for this detector, and no accessories are identified in the verified facts. Treat calibration leaks, sniffing probes and cables as items to specify separately, and source the service schedule from the model instruction manual.