Agilent Technologies RNA QC, DNA QC, Fragment Analyzer
Agilent Technologies RNA QC, DNA QC, Fragment Analyzer — Automated electrophoresis.
The Agilent Fragment Analyzer is a 12-capillary automated electrophoresis system for RNA and DNA QC, running 12 samples per day with 2 µL per well and a 50-minute analysis. Its 22 cm effective length and CCD detection support sizing from 75 bp with 5% accuracy and quantification over two orders of magnitude, delivering RQN quality scores on a 1–10 scale.
Agilent Technologies Fragment Analyzer Systems Series — Model Comparison & Selection
| Model | Measurement range | Plate capacity | Average sizing of 2 200 nt ivt mrna, nt | Lower marker size of hs rna kit, nt | Maximum ivt mrna sample size analyzed, nt | Sample volume per well, microliter |
|---|---|---|---|---|---|---|
| RNA QC, DNA QC, Fragment Analyzer Current | — | 12 | — | — | — | 2 |
| 5200 Fragment Analyzer | — | — | 2370 | 15 | 6000 | 2 |
| 5300 Fragment Analyzer | — | — | 2370 | 15 | 6000 | — |
| Fragment Analyzer Capillary Arrays | — | 12 | — | — | — | 2 |
| Ultra-high-throughput fragment analysis 5400 Fragment Analyzer | 0.5 | nine plates | 2370 | 15 | 6000 | — |
Full specifications
| Analysis time | 50 min |
| Analysis Time6 | 55 min |
| Analysis Time7 | 40 min |
| Detector type | Charged Coupled Device |
| Plate capacity | 12 samples |
| Sample Input Volume | 2 µL |
| Sample volume | 2 µl |
| Sample Volume Per Well | 2 µL |
| Separation resolution mfr | 3 bp |
| Dilutions per sample mfr | single single |
| Gel capacity mfr | Two gel gel |
| Input concentration dynamic range mfr | two orders of magnitude magnitude |
| RQN quality score scale mfr | 1...10 |
| Sizing range mfr | 200 nt |
| Sizing accuracy mfr | 20 |
| Sizing precision mfr | 20 |
| Quantification accuracy mfr | 30 |
| Quantification precision mfr | 20 |
| Quantification range (DNA Fragment) mfr | 0.1 ng/μL |
| Quantification range (DNA Smear) mfr | 5 ng/μL |
| Guaranteed shelf life mfr | 4 months |
| Kit size mfr | 500 samples |
| DNA fragment concentration range mfr | 0.5 ng/μL |
| Number of capillaries mfr | 12 capillaries |
| RQN scale mfr | 1...10 |
| Capillary arrays mfr | 12 arrays |
| n–1 resolution mfr | 60 nt |
| Samples separated per run mfr | 12 samples |
| Maximum queued samples mfr | 288 samples |
| Capillary counts mfr | 12 capillaries |
| sample separation time mfr | 30 minutes |
| samples per run mfr | 12 samples |
| capillary array options mfr | 12 arrays |
| resolution range mfr | 60 nt |
| Maximum DNA concentration mfr | 600 sample |
| Limit of detection (S/N > 3) or sensitivity mfr | 50 pg/μL |
| Input concentration range mfr | 50 pg/μL |
| Quantitative range mfr | 50 pg/μL |
| Maximum DNA concentration per fragment mfr | 600 pg/μL |
| Maximum DNA concentration per total sample mfr | 5 ng/μL |
| Final sample volume (Plasmid DNA Kit) mfr | 24 μL |
| Effective Length | 22 cm |
| Length | 47 cm |
| Effective length (FA 12-Capillary Array Ultrashort) mfr | 22 cm |
| Total length (FA 12-Capillary Array Ultrashort) mfr | 47 cm |
| Effective length (FA 12-Capillary Array Short) mfr | 33 cm |
| Total length (FA 12-Capillary Array Short) mfr | 55 cm |
| Effective length (FA 12-Capillary Array Long) mfr | 55 cm |
| Total length (FA 12-Capillary Array Long) mfr | 80 cm |
| Standard Warranty | One-year |
Description
Construction and series positioning
- This is the 12-capillary configuration of the Fragment Analyzer series, distinguished from the 5200 (medium throughput, 12–96 samples one to three times per day), 5300 (high-throughput, one to two 96-well plates up to three times per day) and 5400 (ultrahigh-throughput with robotic automation, more than two 96-well plates per day) by its fixed 12-capillary array and 12-sample daily throughput.
- Separation takes place in a 22 cm effective-length capillary array with CCD detection; two gels can be loaded per run, and each sample is measured without dilution (single dilution per sample).
- Reagent kits are room-temperature stable with a guaranteed shelf life of 4 months and are supplied in 500-sample kit sizes.
Analytical behavior
- Sizing spans from 75 bp upward, with 5% sizing accuracy and 2% CV sizing precision; quantification accuracy is 25% with 15% CV precision.
- The input concentration dynamic range covers two orders of magnitude; DNA fragment quantification starts at 0.5 ng/µL, DNA smear quantification at 5 ng/µL, and the DNA fragment concentration range begins at 0.1 ng/µL.
- RNA quality is reported as an RQN score on a 1–10 scale; separation resolution is specified as 100.
Operation and control
- A run processes 12 samples at 2 µL per well in 50 minutes, giving a nominal throughput of 12 samples per day.
- The system uses consumable 12-capillary arrays (ultrashort, short and long variants are listed in the consumables documentation) and application-specific DNA/NGS reagent kits (DNF-473, DNF-474, DNF-476, DNF-477, DNF-905, DNF-910, DNF-915, DNF-920 and others).
- No electrical, interface, environmental or compliance specifications are stated in the verified facts; these must be confirmed against the instrument manual before integration.
Integration & Operating Notes
Samples outside the two-orders-of-magnitude input concentration dynamic range fall outside the validated quantification window; DNA fragment quantification begins at 0.5 ng/µL and DNA smear quantification at 5 ng/µL, so dilute concentrated samples or concentrate dilute ones before loading to keep results within the specified accuracy.
Reagent kits are room-temperature stable but carry a guaranteed shelf life of 4 months; inventory must be rotated so that kits are consumed within this window, since expired reagents invalidate the RQN and quantification results without necessarily producing an instrument error.
Selection & Integration Q&A
Pick the 12-capillary configuration for about 12 samples per day at 2 µL per well and 50 minutes per run. Move to the 5200 for 12–96 samples one to three times daily, the 5300 for one to two 96-well plates up to three times daily, or the 5400 when more than two plates per day with robotic automation are required.
The base instrument requires FA 12-capillary arrays (ultrashort, short or long) and application-specific DNA/NGS reagent kits such as DNF-473, DNF-474, DNF-476, DNF-477, DNF-905, DNF-910, DNF-915 or DNF-920; kits are sized for 500 samples and are room-temperature stable for 4 months, so plan array and kit inventory against the 12-sample daily throughput.
Load 2 µL per well into the 12-capillary array and keep input concentration within the two-orders-of-magnitude dynamic range; DNA fragment quantification starts at 0.5 ng/µL and DNA smear at 5 ng/µL, so samples below these levels must be concentrated before the 50-minute run.
Reagent kits must be consumed within their 4-month guaranteed shelf life despite room-temperature storage, and capillary arrays are consumable items replaced per the array type in use; no electrical, environmental or service-interval data are given in the verified facts, so the instrument manual must be consulted for the maintenance schedule.