No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Helium Leak Detectors for Vacuum & Sniffing Applications

Agilent Technologies Helium Leak Detectors for Vacuum & Sniffing Applications — Vacuum technologies.

Helium leak detectors configured for both vacuum-chamber testing and sniffing-mode leak location on roll-to-roll metal deposition lines. The matched web-width data (1660 mm deposited layer, 1300 mm Cu/Al electrolytic foil, 650 mm rolled Al foil) defines the coating-line envelope this detector serves, not a detector rating. Used to qualify vacuum integrity of R2R deposition chambers and locate leaks on the web path.

Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection

Model Motor power, kWBase pressure, mbarDiffusion pump pumping speed, L/sMaximim width, mmMaximum web width deposited layer, mmMaximum web width electrolytic foil cu al, mm
Helium Leak Detectors for Vacuum & Sniffing Applications Current ——5000065016601300
Diffusion Pumps, ——5000065016601300
Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps 0.1193.3————
Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations —10————
Vacuum Components - Flanges, Fittings, Valves, & Greases ——————

Full specifications

Core Performance & Functional Specifications
Diffusion Pump Pumping Speed 50000 L/s
Thickness 6...100 µm
Substrate thickness (rolled foil, Al) mfr 6...100 μm
Substrate thickness (electrolytic foil, Cu/Al) mfr 5...140 μm
Substrate thickness mfr 50 μm
unwind zone pressure mfr 10...1 mbar
turbomolecular pump pumping speed mfr 70...2,000 L/s
bulk metal foil thickness mfr 4...10 μm
replacement film thickness mfr 1 μm
automotive energy density requirement mfr 400 Wh/kg
energy density increase mfr 20
CO2 emission reduction mfr 20
Dimensions, Weight & Mechanical Design
Maximim Width 650 mm
Maximum Web Width (deposited Layer) 1660 mm
Maximum Web Width (electrolytic Foil, Cu/al) 1300 mm
Maximum Web Width (rolled Foil, Al) 650 mm
anode/cathode collector weight reduction mfr 50...60
Electrical, Power & Drive Specifications
battery weight reduction mfr 15
Materials, Media & Process Compatibility
Coating thickness (deposited layer) mfr 50 μm

Description

Positioning in the series

Process envelope served

Documentation scope

Integration & Operating Notes

Process Limits
Web-width figures describe the coating line, not the detector

The 1660 mm deposited-layer, 1300 mm electrolytic-foil and 650 mm rolled-foil widths are maximum web widths of the roll-to-roll process this detector supports. They must not be read as detector dimensions or as limits on the leak-test connection; size the detector interface to the chamber port, not to web width.

Factory Specification Sheet

Selection & Integration Q&A

When should this helium leak detector be chosen instead of the diffusion, Roots, scroll or turbo pumping siblings?

The siblings are pumps that create vacuum; this unit verifies vacuum integrity by helium testing in both vacuum-chamber and sniffing modes. Pick it when the task is leak location or acceptance testing on the R2R deposition chamber, and pair it with the appropriate pump from the series rather than substituting one for the other.

What must be confirmed about the chamber port and adjacent pumping stage before connecting this detector?

The supplied documents give no flange, fitting or backing-pump data for this detector. Confirm the chamber test port size and the available backing vacuum from the installed pump (diffusion, Roots, scroll or turbo station) against the detector's own manual before ordering adapters; do not infer connection geometry from the web-width specifications.

What environment and duty-cycle limits apply when testing a roll-to-roll deposition line?

No environmental or duty-cycle ratings are stated in the supplied documents. The process context is a 50 µm deposited layer on webs up to 1660 mm wide, with foil substrates from 5 to 140 µm; test scheduling must respect web handling of these thin substrates. Confirm ambient and cycle limits from the model manual.

What maintenance schedule and accessories come with the base delivery?

The attached documents list no maintenance intervals, cables, probes or consumables for this detector, and no accessories are identified in the verified facts. Treat calibration leaks, sniffing probes and cables as items to specify separately, and source the service schedule from the model instruction manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Vacuum and Leak Detection in Roll-to-Roll Lithium Battery Manufacturing
Brochure ·2,9 МБ ·10 pp.
View PDF