No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Diffusion Pumps,

Agilent Technologies Diffusion Pumps, — Vacuum technologies.

The Agilent diffusion pump line is represented here only by a roll-to-roll web-coating technical overview, not by pump specifications. The verified data describe a deposition process: 1660 mm maximum deposited-layer web width, 1300 mm for electrolytic Cu/Al foil, and 650 mm for rolled Al foil. No pump geometry, speed, or fluid data are available.

Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection

Model Motor power, kWBase pressure, mbarDiffusion pump pumping speed, L/sMaximim width, mmMaximum web width deposited layer, mmMaximum web width electrolytic foil cu al, mm
Diffusion Pumps, Current ——5000065016601300
Helium Leak Detectors for Vacuum & Sniffing Applications ——5000065016601300
Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps 0.1193.3————
Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations —10————
Vacuum Components - Flanges, Fittings, Valves, & Greases ——————

Full specifications

Core Performance & Functional Specifications
Diffusion Pump Pumping Speed 50000 L/s
Thickness 6...100 µm
Substrate thickness (rolled foil, Al) mfr 6...100 μm
Substrate thickness (electrolytic foil, Cu/Al) mfr 5...140 μm
Substrate thickness mfr 50 μm
unwind zone pressure mfr 10...1 mbar
turbomolecular pump pumping speed mfr 70...2,000 L/s
bulk metal foil thickness mfr 4...10 μm
replacement film thickness mfr 1 μm
automotive energy density requirement mfr 400 Wh/kg
energy density increase mfr 20
CO2 emission reduction mfr 20
Dimensions, Weight & Mechanical Design
Maximim Width 650 mm
Maximum Web Width (deposited Layer) 1660 mm
Maximum Web Width (electrolytic Foil, Cu/al) 1300 mm
Maximum Web Width (rolled Foil, Al) 650 mm
anode/cathode collector weight reduction mfr 50...60
Electrical, Power & Drive Specifications
battery weight reduction mfr 15
Materials, Media & Process Compatibility
Coating thickness (deposited layer) mfr 50 μm

Description

What the verified facts actually cover

Positioning inside the series

Behavior and operation

Integration & Operating Notes

Process Limits
Web width depends on foil type and deposition stage

The allowable web width is not a single number: 1660 mm applies to the deposited layer, 1300 mm to electrolytic Cu/Al foil, and 650 mm to rolled Al foil. Line layout and roll-handling hardware must be sized to the narrowest relevant case for the foil actually run.

Factory Specification Sheet (matched specs
Process Limits
Substrate thickness window differs between foil types

Rolled Al foil is specified at 6–100 µm and electrolytic Cu/Al foil at 5–140 µm, with a 50 µm deposited layer. Tension and transport settings must be validated per foil type; the two ranges are not interchangeable on one setup without re-checking web handling.

Factory Specification Sheet (extra specs
Maintenance
No pump service data were supplied for this model

The attached document is a process overview of roll-to-roll metal deposition and contains no maintenance intervals, fluid-change schedules, or error codes. Service planning for the diffusion pump itself must come from the pump manual, which is not part of the verified facts.

Technical overview: vacuum leak detection roll-to-roll metal deposition (5994-8607EN

Selection & Integration Q&A

When should this diffusion-pump entry be chosen over the other vacuum products in the series, such as the dry scroll or turbo pumping systems?

The verified facts do not contain diffusion-pump performance data, so a defensible choice against scroll or turbo systems cannot be made from this card. The only process data supplied concern roll-to-roll web deposition widths (1660/1300/650 mm) and foil thicknesses, not pump speed or pressure.

What adjacent system data are needed before integrating this pump into a roll-to-roll deposition line?

The supplied facts give web widths and foil thicknesses only; they do not state inlet flange size, backing-pump requirements, or fluid type. Those must be taken from the pump manual, which is not among the verified documents, before matching foreline and flange hardware.

What mounting and duty-cycle limits apply to this diffusion pump?

No mounting orientation, ambient temperature, cooling-water, or duty-cycle limits appear in the verified facts. The attached document is a process overview without installation sections, so these limits must be confirmed from the pump manual before installation planning.

What maintenance schedule and accessories are included with this pump?

The verified facts list no maintenance intervals, consumables, cables, or included accessories, and no certificates. The only document is a roll-to-roll deposition overview with no service content, so fluid, heater, and seal spares must be defined from the pump manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Vacuum and Leak Detection in Roll-to-Roll Lithium Battery Manufacturing
Brochure ·2,9 МБ ·10 pp.
View PDF