Agilent Technologies 20.60 CFM
Agilent Technologies 20.60 CFM — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h, Ultimate pressure 3.3 mbar.
The Agilent IDP 20.60 CFM is an oil-free dry scroll vacuum pump in the IDP family, configured for 100–120 VAC operation and rated at 60 L/min pumping speed with a 3.3 mbar base pressure. Its 0.16 HP motor and scroll architecture suit clean, hydrocarbon-free backing duty in analytical and laboratory vacuum systems.
Agilent Technologies Idp Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Ultimate pressure, mbar | Pumping speed, m³/h | Base pressure, mbar | Supply frequency, Hz | Operating temperature, °C |
|---|---|---|---|---|---|---|
| 20.60 CFM Current | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 26.48 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 6.0 CFM | — | — | — | — | — | — |
| IDP-4 | 0.119 | 2.4 | 3.6 | 3.3 | — | 5 |
| Scroll Pumps for Helium Recirculation & Cryogenic Applications | 0.119 | — | 3.6 | 3.3 | — | — |
Full specifications
| Motor power | 0.16 HP |
| Pumping speed | 60 L/min |
| Ultimate pressure | 3.3 mbar |
| Base Pressure | 3.3 mbar |
| IDP-3, 1φ, 220 V, 50/60 Hz mfr | 3 |
| IDP-3, 1φ, 115 V, 60 Hz mfr | 3 |
| IDP-3, 1φ, 100 V, 50/60 Hz mfr | 3 |
| IDP-3, 24 VDC mfr | 3 |
| IDP-3 tip seal replacement kit mfr | 3 TS |
| Exhaust silencer kit mfr | 110 |
| Inlet trap mfr | 25 |
| Vibration isolation kit mfr | 110 VIBISOKIT |
| Description mfr | Part number number |
| IDP-7 mfr | Vibration isolation kit kit |
| IDP-7 with inlet isolation valve mfr | 3807 |
| IDP-7/10 tip seal replacement kit mfr | 3807 |
| Purge kit mfr | 3807 |
| Gas ballast kit mfr | 3807 |
| IDP-10 mfr | 3810 |
| IDP-10 with inlet isolation valve mfr | 3810 |
| IDP-15 mfr | 3815 |
| IDP-15 with inlet isolation valve mfr | 3815 |
| IDP-15 tip seal replacement kit mfr | 3815 |
| IDP-35 mfr | 3835 |
| IDP-35 with Gauge mfr | 3835 |
| IDP-35 with Inlet Valve mfr | 3835 |
| IDP-35 with Inlet Valve and Gauge mfr | 3835 |
| Inlet HEPA filter, NW40 mfr | 40 |
| HEPA filter, NW25 mfr | 25 |
| IDP-45 mfr | 3845 |
| IDP-45 with Gauge mfr | 3845 |
| IDP-45 with Inlet Valve mfr | 3845 |
| IDP-45 with Inlet Valve and Gauge mfr | 3845 |
| inlet valve closing time mfr | 20 milliseconds |
| inlet valve opening time mfr | 10 seconds |
| Pirani gauge pressure range mfr | -4...1000 mbar |
| IDP-3 mfr | Vibration isolation kit kit |
| IDP-4 mfr | Replacement filter element element |
| inlet valve opening time after power restore mfr | 10 seconds |
| tip seal replacement duration mfr | half an hour hour |
| IDP-4 maintenance duration mfr | 15...30 minutes |
| integrated Pirani gauge pressure range mfr | -4...1000 mbar |
| VPI valve isolation time mfr | 20 ms |
| Supply frequency | 50 Hz |
| Operating voltage mfr | 100 VAC |
Description
Construction and series positioning
- Oil-free dry scroll mechanism driven by a 0.16 HP motor; no sealing oil in the swept volume.
- This modification is the 100–120 VAC variant of the IDP family; the same series spans smaller and larger displacements (2.1, 5.4, 6.0, 26.48 CFM siblings) and 200–240 VAC motor variants.
- Base pressure is 3.3 mbar, matched to the 60 L/min pumping speed class.
Behavior and operating envelope
- Performance is quoted at a single operating point (60 L/min, 3.3 mbar); no digitized curve data is available for this model, so part-load behavior should be taken from the family brochure rather than extrapolated.
- The scroll stage tolerates continuous duty as a backing pump; ultimate pressure is the floor for the inlet, not a guaranteed working pressure under gas load.
Installation and control
- Operating voltage is 100–120 VAC; the motor variant must be matched to the site supply before commissioning.
- The family documentation covers 50 Hz and 60 Hz operating points; confirm the frequency-specific performance for the installed supply.
- No controller, cabling or inlet fittings are specified in the verified facts; these are treated as separate integration items.
Integration & Operating Notes
This modification is the 100–120 VAC version; connecting it to a 200–240 VAC line, or ordering the wrong variant for a 230 V site, will damage the motor. Confirm supply voltage and frequency (50 or 60 Hz) before commissioning, since the family is documented at both operating points.
The inlet should be sized so the process gas load keeps the pump above its 3.3 mbar base pressure; operating continuously at the ultimate pressure with high gas throughput shifts the effective pumping speed below the 60 L/min rating. Use the family performance data for the actual inlet pressure of the application.
Because the pump is oil-free, the scroll tip seals and bearings are the consumable elements; base pressure drift upward from 3.3 mbar is the usual indicator that seal replacement is due. Plan seal and bearing service against the family maintenance schedule rather than waiting for a pressure failure.
Selection & Integration Q&A
Pick this one when the required backing speed is around 60 L/min at 3.3 mbar and the site is 100–120 VAC. The 26.48 CFM sibling shares the same 60 L/min and 3.3 mbar figures but is a different frame; the 5.4 and 6.0 CFM units suit lower-throughput chambers. Confirm the voltage variant before ordering.
A 100–120 VAC supply at the correct frequency (50 or 60 Hz) matched to the motor variant, plus inlet and exhaust fittings and any vibration isolation, none of which are included in the base delivery. The pump is a backing stage, so the high-vacuum pump and its flange interface must be specified separately.
Scroll tip seals and bearings are the wear items on this oil-free design; base-pressure drift above 3.3 mbar signals seal service. Inlet fittings, exhaust line, isolation mounts and any cabling are not in the base delivery and must be ordered as accessories. Follow the family brochure service schedule.