Agilent Technologies natural gas analyzer, fast analysis times
Agilent Technologies natural gas analyzer, fast analysis times — Gas chromatography.
The Agilent natural gas analyzer is a factory-configured, chemically tested three-channel GC system built on the 8890 GC or 990 Micro GC platform, equipped with three valves, four columns, and TCD/FID detection. It delivers a 20-minute analysis with a typical quantitation limit of 0.01 mol%, covering H2, O2, N2, and extended hydrocarbons per UOP 1945. It is positioned for fast, method-compliant natural gas composition analysis within the Energy Chemical GC Analyzer series.
Agilent Technologies Energy Chemical GC Analyzers Series — Model Comparison & Selection
| Model | Typical quantitation limit, mol% | Carrier gas | Analysis time, min |
|---|---|---|---|
| natural gas analyzer, fast analysis times Current | 0.01 | — | 20 |
| Analyzers for biodiesel, biofuels | 0.01 | — | — |
| Gasoline analyzer, benzene analysis | 0.01 | — | — |
| GCxGC-based analyzers, aviation turbine fuels | — | Hydrogen | — |
| NGA Analyzer, natural gas analysis | 0.01 | — | 20 |
| Refinery gas analyzer, four channel multi-dimensional system | — | Argon | — |
Full specifications
| Analysis time | 20 minutes |
| Typical Quantitation Limit | 0.01 mol% |
| Valves mfr | 3 |
| Detectors mfr | TCD/FID TCD/FID |
| Columns mfr | 4 |
| Analyzer channels mfr | Three-channel channel |
| Configured per published method mfr | 1945 UOP |
| Analysis capacity for H2 mfr | Yes Yes |
| Analysis capacity for O2 and N2 mfr | Yes Yes |
| Extended hydrocarbon analysis mfr | Yes Yes |
Description
Construction and series positioning
- Three-channel architecture with three valves and four columns, configured at the factory and chemically tested before delivery.
- Detection by TCD/FID combination, enabling both permanent gas (H2, O2, N2) and hydrocarbon analysis in one run.
- Built on either the Agilent 8890 GC or the 990 Micro GC platform; the specific platform is fixed by the ordered option (#610, #611, #612, #613, or #615).
- Within the series, this modification is the fast natural gas analyzer; sibling models address biodiesel/biofuels, refinery gas (RGA), gasoline/benzene, and aviation turbine fuels via GCxGC.
Analytical behavior
- Analysis time is 20 minutes per sample, with a typical quantitation limit of 0.01 mol%.
- The configuration supports H2, O2, and N2 analysis as well as extended hydrocarbon analysis, all within the same three-channel run.
- Method compliance is tied to UOP 1945 as the published method for this configuration.
Installation, control, and operation
- The analyzer is factory-configured and chemically tested; site integration must respect the selected option's platform (8890 GC or 990 Micro GC) and its utilities.
- The GC gasifier accessory (Part Number G3535A) is available for the 990 Micro GC, 8860 GC, and 8890 GC, but is not part of the base analyzer delivery.
- Standard, extended, and sour gas configurations exist; the ordered option determines which is supplied.
Integration & Operating Notes
The analyzer family is offered in standard, extended, and sour gas configurations. If the sample stream contains sour components, the standard configuration must not be used; the sour gas option must be ordered and the sample conditioning must match it. Confirm the stream composition before selecting the option.
Selection & Integration Q&A
Choose this model when the sample is natural gas and a 20-minute run with 0.01 mol% typical quantitation limit is required, including H2, O2, N2, and extended hydrocarbons per UOP 1945. Select the RGA sibling for refinery gas streams and the gasoline/benzene sibling for fuel analysis; those cover different matrices and methods.
The analyzer is factory-configured and chemically tested, but the GC gasifier accessory (G3535A) is a separate part and not included in base delivery. The platform (8890 GC or 990 Micro GC) is fixed by the ordered option, so site utilities and sample-handling hardware must be matched to that platform.
The family includes standard, extended, and sour gas configurations. If the natural gas stream contains sour components, the standard configuration is not appropriate; the sour gas option must be ordered. Confirm stream composition before selecting the option, because the configuration is fixed at the factory.
Plan for the GC gasifier accessory (G3535A) as a separate order if condensable samples are involved; it is not in the base delivery. Because the unit is factory-configured and chemically tested, service and consumables should follow the platform actually supplied (8890 GC or 990 Micro GC) and the ordered option number.