No photo available yet
Agilent Technologies Gasoline analyzer, benzene analysis
Agilent Technologies Gasoline analyzer, benzene analysis — Gas chromatography.
The Agilent gasoline analyzer for benzene analysis is a three-channel gas chromatograph configured to UOP 1945, quantifying benzene in gasoline-range streams down to 0.01 mol%. It also measures H2, O2, N2, and extended hydrocarbons, serving refinery and fuel-quality laboratories that need a single instrument for light-gas and aromatic speciation.
Agilent Technologies Energy Chemical GC Analyzers Series — Model Comparison & Selection
| Model | Typical quantitation limit, mol% | Carrier gas | Analysis time, min |
|---|---|---|---|
| Gasoline analyzer, benzene analysis Current | 0.01 | — | — |
| Analyzers for biodiesel, biofuels | 0.01 | — | — |
| GCxGC-based analyzers, aviation turbine fuels | — | Hydrogen | — |
| natural gas analyzer, fast analysis times | 0.01 | — | 20 |
| NGA Analyzer, natural gas analysis | 0.01 | — | 20 |
| Refinery gas analyzer, four channel multi-dimensional system | — | Argon | — |
Full specifications
| Typical Quantitation Limit | 0.01 mol% |
| Analyzer channels mfr | Three-channel channel |
| Configured per published method mfr | 1945 UOP |
| Analysis capacity for H2 mfr | Yes Yes |
| Analysis capacity for O2 and N2 mfr | Yes Yes |
| Extended hydrocarbon analysis mfr | Yes Yes |
Description
Construction and series positioning
- This is a three-channel GC analyzer dedicated to benzene in gasoline, configured per UOP 1945; it is one member of the Agilent energy and chemical analyzer portfolio, distinct from the biodiesel/biofuel, refinery gas (RGA), GCxGC aviation-turbine-fuel, and LPG analyzer siblings.
- The three-channel architecture supports parallel analysis of light permanent gases (H2, O2, N2) and extended hydrocarbons alongside the benzene determination, so a single injection sequence covers both permanent-gas and aromatic information.
Analytical behavior
- Typical quantitation limit is 0.01 mol% for benzene, which sets the lower reporting boundary for the aromatic channel; results below this level should not be reported as quantified.
- The instrument is configured to the published UOP 1945 method, so chromatographic conditions, column set, and calibration approach follow that procedure rather than a generic GC configuration.
Installation and operation
- The attached brochure digest lists the analyzer under the fuel-analyzer group of the portfolio but provides no installation, utility, or control details; site requirements (carrier gas, power, detector gases, data system) must be taken from the model-specific site-planning and instruction documents, which are not included in the supplied digests.
Integration & Operating Notes
The typical quantitation limit of 0.01 mol% defines the lowest benzene concentration that can be reported as a quantified value. Samples expected below this level need a different configuration or concentration step; reporting sub-limit values as quantitative results is invalid.
Because the analyzer is configured per UOP 1945, column set, temperature program, and calibration must follow that published method. Altering the method without revalidation changes the benzene result and breaks comparability with UOP 1945 reporting.
The three-channel architecture splits permanent gases (H2, O2, N2), extended hydrocarbons, and the benzene determination across separate channels. Integration and reporting logic must align the channels to a single sample run so results are attributed to the correct injection.
Selection & Integration Q&A
Choose this unit when the matrix is gasoline-range liquid and the target is benzene per UOP 1945 with a 0.01 mol% quantitation limit. The LPG analyzer targets liquefied petroleum gas composition, and the RGA solution targets refinery gas streams; neither is configured for UOP 1945 benzene in gasoline.
The supplied documents do not list carrier gas, detector gas, power, or data-system requirements. These must be taken from the model-specific site-planning guide before ordering; the brochure digest only places the unit in the fuel-analyzer group and gives no utility data.
No mounting, ambient temperature, or humidity limits are stated in the supplied specification sheet or brochure digest. Confirm laboratory bench space and environmental control from the site-planning document; do not assume values from other series members.
The supplied documents give no maintenance interval, spare-part list, or consumables schedule. Columns, calibration standards, carrier and detector gases, and the data system should be treated as items to confirm separately; service intervals must come from the model-specific manual.