Agilent Technologies Vacuum Components - Flanges, Fittings, Valves, & Greases
Agilent Technologies Vacuum Components - Flanges, Fittings, Valves, & Greases — Vacuum technologies.
The Agilent Vacuum Components line covers flanges, fittings, valves, and greases for vacuum system construction, not a single pump or instrument. No model-specific performance data is available; selection depends on the required flange standard, fitting size, and valve type. These components serve as the connective hardware between pumps, chambers, and gauges.
Agilent Technologies Vacuum Technologies Series — Model Comparison & Selection
| Model | Motor power, kW | Base pressure, mbar | Diffusion pump pumping speed, L/s | Maximim width, mm | Maximum web width deposited layer, mm | Maximum web width electrolytic foil cu al, mm |
|---|---|---|---|---|---|---|
| Vacuum Components - Flanges, Fittings, Valves, & Greases Current | — | — | — | — | — | — |
| Diffusion Pumps, | — | — | 50000 | 650 | 1660 | 1300 |
| Helium Leak Detectors for Vacuum & Sniffing Applications | — | — | 50000 | 650 | 1660 | 1300 |
| Scroll Pumps, Dry, Quiet, Oil-Free Vacuum Pumps | 0.119 | 3.3 | — | — | — | — |
| Turbo Pumping Systems (TPS), Turbomolecular Pumping Stations | — | 10 | — | — | — | — |
Full specifications
| Degassing | The removal of gas from a material, usually by application of heat under high vacuum. |
| Electron Charge | 1.602 coulomb |
| Molar Volume | 22.41 liters |
| Acceleration due to gravity mfr | 9.8066 |
| Angstrom unit mfr | 10 m |
| Avogadro's number mfr | 6.02214076 |
| Boltzmann's constant mfr | 1.38064852 |
| Equivalent of heat mfr | 4.185 |
| Natural log base mfr | 2.7183 |
| Velocity of light mfr | 2.9979 |
| Velocity of sound mfr | 343 |
| Magnetic flux density mfr | 1 |
| Pressure conversion mfr | 1 atm |
| Pumping speed conversion mfr | 1 h |
| Throughput conversion mfr | 1 cc/sec |
| Outgassing rate mfr | 2 |
| Molecular density mfr | 3.25 |
| Molecular collision rate mfr | 3.78 sec |
| Mean free path mfr | 5.1 cm |
| Monolayer formation time mfr | 2.2 sec |
| Flow/leak rate conversion mfr | 1 sccm |
| Planck's constant mfr | 6.62607 sec |
| ISO/DIS 3556 / 1 mfr | Sputter Ion Pumps - Measurement of Performance C |
| ISO/DIS 3568 mfr | Ionization Vacuum Gauges – Calibration by direct |
| ISO/DIS 3570 / 1 mfr | Vacuum Gauges – Standard Methods for Calibration |
| ISO/DIS 3669 mfr | Bakeable Flange Dimensions Dimensions |
| PN5ASR CC/5 mfr | Vacuum Pumps, Acceptance Specifications Refriger |
| Hydrogen mfr | 2 |
| Helium mfr | He He |
| Deuterium mfr | 2 H |
| Methane mfr | 4 |
| Ammonia mfr | 3 |
| Water (vapour) mfr | 2 O |
| Neon mfr | Ne Ne |
| Nitrogen mfr | 2 |
| Oxygen mfr | 2 |
| Argon mfr | Ar Ar |
| Carbon dioxide mfr | 2 |
| Krypton mfr | Kr Kr |
| Xenon mfr | Xe Xe |
| Mercury mfr | Hg Hg |
| Critical forepressure mfr | See maximum tolerable foreline pressure. pressur |
| Convection mfr | The transfer of heat from one place to another b |
| Desorption mfr | See outgassing. outgassing. |
| Evaporation mfr | The process that happens when a liquid or solid |
| Dynamic seal mfr | A seal that moves. moves. |
| Gas density mfr | The number of molecules per unit of volume. volu |
| High vacuum mfr | 10 |
| Gas load mfr | See pressure, gauge. gauge. |
| General gas law mfr | 1 |
| Foreline valve mfr | A vacuum valve placed in the foreline to permit |
| Implosion mfr | In vacuum work, the inward collapse of the walls |
| Foreline mfr | The section of a pump through which the gases le |
| viscous flow pressure limit mfr | 1 millibar |
| molecular flow pressure limit mfr | 10 millibar |
| pump-down equation upper validity mfr | 1 mbar |
| diffusion pump intake pressure limit mfr | 2 mTorr |
| diffusion pump forepressure limit mfr | 500 mTorr |
| high vacuum range lower bound mfr | 10 Torr |
| rough vacuum range upper bound mfr | 10 Torr |
| ultrahigh vacuum range lower bound mfr | 10 Torr |
| ultrahigh vacuum range upper bound mfr | 10 Torr |
| throughput to power conversion mfr | 5.70 watt |
| Atomic Mass Unit | 1.6605 grams |
| Helium mass spectrometer leak detector (hmsld) mfr | See mass spectrometer leak detector. detector. |
| Standard pressure mfr | 1013 mbar |
| DIN 28400 mfr | Vacuum Technology; Designations and Definitions |
| DIN 28401 mfr | Graphic Symbols in Vacuum Technology Technology |
| DIN 28402 mfr | Vacuum Technology: Variables, Symbols, Units - O |
| DIN 28403 ISO 1609 PNEUROP 6606 mfr | Vacuum Technology; Quick Connections, Small Flan |
| DIN 28404 ISO 1609 PNEUROP 6606 mfr | Vacuum Technology: Flanges, Dimensions Dimension |
| DIN 28410 mfr | Vacuum Technology; Mass Spectrometer Partial Pre |
| DIN 28411 ISO 3530.2 mfr | Mass Spectrometer type Leak Detector Calibration |
| DIN 28416 mfr | Calibration of Vacuum Gauges – General Method Me |
| DIN 28417 mfr | Measurement of Throughput by Volumetric Method M |
| DIN 28418 ISO/DIS 3567 mfr | Vacuum Gauges – Calibration by Direct Comparison |
| DIN 28426, part I, II ISO 1607 / 1,2 PNEUROP 6602 mfr | Positive Displacement Vacuum Pumps- Measurement |
| DIN 28427 ISO 1608 / 1,2 PNEUROP 5607 mfr | Vapor Vacuum Pumps - Measurement of Performance |
| DIN 28428 PNEUROP 5608 mfr | Vacuum Technology; Acceptance Specifications for |
| DIN 28429 PNEUROP 5615 mfr | Vacuum Technology; Acceptance Specifications for |
| DIN 28430 PNEUROP 6601 mfr | Measurement of Performance of Ejector Vacuum Pum |
| ISO 1314 mfr | Pressure; Basic Definitions, Units Units |
| ISO 3529 I,II,III mfr | Vacuum Technology Vocabulary Vocabulary |
| standard atmosphere mfr | 101325 pascals |
Description
Construction and positioning
- This entry is a component category, not a discrete machine model; it spans flanges, fittings, valves, and greases used to assemble and maintain vacuum systems.
- Sibling entries in the same series are complete pumps (diffusion, roots, scroll) and leak detectors; this category supplies the interfaces and sealing hardware those systems require.
- No certificates, applications, or model-specific specifications are provided for any individual component.
Behavior and media
- No curve points or operating ranges are available for this category; performance depends on the specific component selected (e.g., valve conductance, flange leak rate).
- The attached reference booklet provides formulas and tables (conductance, pump-down, outgassing, unit conversions) that support system-level calculations, but it does not define component ratings.
Installation and operation
- Installation, connection, and control specifics are not documented in the provided digests; refer to individual component datasheets and the vacuum technology standards referenced in the booklet (e.g., DIN 28401 graphic symbols).
Integration & Operating Notes
The provided facts contain no pressure, temperature, or leak-rate ratings for any flange, fitting, valve, or grease. Engineers must obtain the specific component datasheet to confirm compatibility with the system's base pressure, bakeout temperature, and gas load.
Selection & Integration Q&A
Choose this category when you need to connect, seal, isolate, or maintain an existing vacuum system—flanges to mate components, valves to control flow, greases to lubricate seals. Complete pumps (diffusion, roots, scroll) are separate sibling entries for generating vacuum, not for interconnection.
Verify the flange standard (e.g., ISO-K, CF), nominal diameter, and seal material match both mating surfaces. Confirm the valve's pressure rating and conductance suit the pump's throughput and the chamber's base pressure. The reference booklet provides conductance formulas and unit conversions to support these calculations.
No mounting or environmental limits are stated in the provided facts. In practice, limits depend on the specific component: bakeout temperature for flanges and valves, ambient temperature for elastomer seals, and cleanliness requirements for greases. Always refer to the individual component datasheet.
The base delivery typically includes only the component itself; consumables such as centering rings, O-rings, clamp bolts, and grease cartridges are usually ordered separately. No specific accessory list is provided in the facts; check the individual product page for optional items and spare parts.