Elmo Rietschle 2BV2071
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BV2071

Elmo Rietschle 2BV2071 — Liquid Ring Vacuum Pumps with Motor power 8.6 kW, Pumping speed 500 m³/h.

Single-stage liquid ring vacuum pump 2BV2071 with 7.3 kW (50 Hz) / 8.6 kW (60 Hz) motor, delivering 500 m³/h at 50 Hz and 575 m³/h at 60 Hz. As the largest 2BV207x variant, it is distinguished by a 1.0 L first-fill and 116/156 mm liquid-level window, and is available in cast iron or stainless steel construction. It serves continuous vacuum duty where the operating liquid is water and the process gas is free of solids.

Motor power
8.6 kW
Pumping speed
500 m³/h

Elmo Rietschle L-BV2 Series — Model Comparison & Selection

Model Motor power, kWOperating principlePumping speed, m³/hNoise level, dBPower supplyWeight, kg
2BV2071 Current 7.3Liquid ring50061AC64
2BV2060 3.5Liquid ring vacuum pump—653~ 50/60 Hz28
2BV2061 3Liquid ring2765AC26
2BV2070 7.3Liquid ring7070AC49

Full specifications

Core Performance & Functional Specifications
Motor power 7.3 kW (50 Hz)
60 Hz: 8.6 kW
Operating principle Liquid ring
Pumping speed 500 m³/h (50 Hz)
60 Hz: 575 m³/h
Dimensions, Weight & Mechanical Design
Number of stages 1 dimensionless
Weight 64 kg
Electrical, Power & Drive Specifications
Power supply AC
Operating Conditions, Environment & Protection
Noise level 61 dB(A)
Protection rating IP55

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Check motor insulation resistance before first start

Dry the windings if insulation resistance is ≤1 kΩ per volt of measurement potential. Supply tolerance is ±5% voltage and ±2% frequency. Maintain a minimum 5.5 mm air gap between non-insulated energized components and earth for UN ≤ 690 V.

Operating Instructions — L-BV2 (EN), Commissioning page 20 and Installation page 19
Control & I/O
ATEX versions require independent feed and level monitoring

For ATEX units, operating-liquid feed monitoring must trip at ≤50% of design flow, and liquid level must be between 116 and 156 mm before start-up. Discharge pressure monitoring (G2) must switch off the unit if 1.1 bar abs is exceeded. These monitoring paths must be independent, even when a PLC is used.

Operating Instructions — L-BV2 ATEX (EN), Concerning 5.2.1 and 5.2.3
Maintenance
Re-grease or replace bearings every 2.5 years or 20,000 h

Use UNIREX N3 grease (or DIN 51825-K3N equivalent), filling approx. 50% of the free space in roller bearings and 65% of adjacent areas. For ATEX units, the interval is 2 years or 18,000 h and weekly dust removal is required. The operator may not perform work requiring dismantling.

Operating Instructions — L-BV2 (EN), Maintenance page 28; ATEX supplement Concerning 9.1
Process Limits
First fill is 1.0 L; use an intake strainer for the first 100 h

Fill the pump with 1.0 L of operating liquid before start-up. Fit an intake strainer in the suction line for the first 100 operating hours to prevent installation residues from entering the unit. Maximum installation altitude is 1000 m above sea level without consultation.

Operating Instructions — L-BV2 (EN), Technical Data page 12 and Installation page 16

Selection & Integration Q&A

When should I choose the 2BV2071 instead of a smaller 2BV2060 or 2BV2061?

Choose the 2BV2071 when you need 500 m³/h at 50 Hz (575 m³/h at 60 Hz) and a 7.3 kW motor. The 2BV2060/2061 use 3.0–3.5 kW motors. The 2BV2071 is available in a higher corrosion-resistance/hygiene construction (together with the 2BV2070 and 2BV5.. types); the standard design is cast iron RAL 9006, with all-stainless variants pickled and passivated.

What are the requirements for the operating-liquid supply and discharge piping?

Provide a flow limiter set to the design flow for the 2BV207. size (first fill 1.0 L). Piping must withstand 1.1 bar abs discharge in vacuum operation and be tightened to max 100 Nm. For ATEX, add independent feed monitoring tripping at ≤50% design flow and discharge pressure switch G2.

Can I install the 2BV2071 outdoors or at high altitude?

Ambient temperature must stay between +5 °C and +40 °C; the IP55 motor is protected against dust and water jets but the pump is not weatherproof. Maximum installation altitude is 1000 m above sea level; consult the manufacturer above this. Ensure 53 mm clearance around the fan guard.

What maintenance and accessories are required beyond the base delivery?

Base delivery excludes suction strainer, liquid separator, flow limiter and monitoring sensors. Fit an intake strainer for the first 100 h. Re-grease or replace bearings every 2.5 years or 20,000 h with UNIREX N3 grease. ATEX units need independent feed/level sensors and pressure switch G2.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — L-BV2 (EN)
Manual ·1,9 МБ ·32 pp.
View PDF
PDF
Technical Data Sheet — L-BV2 2BV2071 IE3 compressor (EN)
Datasheet ·378,1 КБ ·3 pp.
View PDF
PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF