Elmo Rietschle 2BV5111
Elmo Rietschle 2BV5111 — Liquid Ring Vacuum Pumps with Motor power 8.6 kW.
The 2BV5111 is a liquid-ring vacuum pump/compressor in the L-BV5 series, driven by a 7.5 kW (50 Hz) / 8.6 kW (60 Hz) three-phase motor with IP55 protection. It is distinguished from smaller siblings by its 7.5 kW rating and from larger ones by its 3.0 L first-fill and 130/170 mm liquid-level window. It serves as a robust vacuum source for systems handling wet or condensable gas streams.
Elmo Rietschle L-BV5 Series — Model Comparison & Selection
| Model | Motor power, kW | Operating principle | Noise level, dB | Power supply | Pumping speed, m³/h | Weight, kg |
|---|---|---|---|---|---|---|
| 2BV5111 Current | 7.5 | Liquid ring | 72 | 3~ AC | — | 124 |
| 2BV5110 | 5.5 | ring blow | 67 | AC | — | 67 |
| 2BV5121 | 11 | Liquid ring compressor | 70 | AC | 40 | — |
| 2BV5131 | 15 | Liquid ring | 74 | AC | 17.4 | 178 |
| 2BV5161 | 15 | Liquid ring | 74 | AC | 500 | 160 |
| L-BV5 2060 | — | — | — | — | — | — |
Full specifications
| Motor power | 7.5 kW (50 Hz) 60 Hz: 8.6 kW |
| Operating principle | Liquid ring |
| Rotational speed | 1.00 rpm (50 Hz) 60 Hz: 1.32 rpm |
| Weight | 124 kg |
| Power supply | 3~ AC (50/60 Hz) |
| Noise level | 72 dB |
| Protection rating | IP55 |
Description
Construction and series positioning
- The 2BV5111 is a single-stage liquid-ring machine with a cast-iron body and bronze impeller (standard K variant); stainless-steel (H) and CrNi-steel impeller (C) variants are available for corrosive duties.
- Within the L-BV5 series, it sits between the 5.5 kW 2BV5110 and the 11.0 kW 2BV5121, offering a mid-range power step for moderate vacuum demand.
- Unlike the 2BV5121, which is also offered as a liquid-ring compressor, the 2BV5111 is primarily configured for vacuum operation.
- The motor is a 3~ AC unit rated 7.5 kW at 50 Hz and 8.6 kW at 60 Hz, with a nominal speed of 1.00 rpm at 50 Hz (1.32 rpm at 60 Hz) as listed in the data sheet.
Behavior under load and media
- The pump is designed for continuous duty with an operating-liquid flow that must be maintained; the first fill quantity is 3.0 L, and the design operating-liquid flow must be set according to the technical data for the 2BV511.. group.
- It tolerates a maximum gas/vapour temperature of +80 °C; for higher temperatures, the operating-liquid flow must be increased to twice the design flow (for the 2BV5 series) or a pre-condenser must be installed.
- The maximum water carry-over through the inlet is 2.5 times the design operating-liquid flow continuously and 5 times for a maximum of 2 seconds (for 2BV51.. types).
- The minimum suction pressure must remain at least 50 mbar above the vapour pressure of the operating liquid to avoid cavitation; otherwise, the manufacturer must be consulted.
Installation, connection and control
- The pump requires a three-phase supply with voltage tolerance ±5% and frequency tolerance ±2%; the motor insulation resistance must be checked before commissioning, and windings must be dried if the resistance is ≤1 kΩ per volt.
- Piping connections to suction and discharge must not be tightened beyond 100 Nm; an intake strainer should be fitted for the first 100 operating hours.
- Minimum clearances for heat dissipation are 53 mm around the fan guard; the maximum installation altitude is 1000 m above sea level.
- For non-ATEX units, operation with a frequency converter is permitted up to a maximum speed of 2454 min⁻¹ (for 2BV5110/5111); however, ATEX variants explicitly forbid frequency-converter operation.
- The ATEX supplement requires compulsory monitoring of operating-liquid feed (trip at ≤50% of design flow) and liquid level (start-up only within the 130–170 mm window for 2BV5111), as well as pressure monitoring on the discharge side.
Integration & Operating Notes
Exceeding the maximum discharge pressure of 1.3 bar abs (for 2BV5.. types) when the design operating-liquid flow is maintained can overload the pump and damage internal components. Install pressure relief or monitoring on the discharge line.
Operating below this margin causes cavitation, which erodes the impeller and reduces performance. If the process vapour pressure is close to the suction pressure, consult the manufacturer for a suitable configuration.
Excessive vibration from piping misalignment or foundation issues can lead to bearing failure and seal damage. Measure vibration at the points shown in Fig. 7 of the manual after installation and during operation.
If the insulation resistance is ≤1 kΩ per volt of measurement potential, the windings must be dried. Starting with low insulation resistance risks motor failure and electrical shock.
Use UNIREX N3 grease or equivalent per DIN 51825-K3N, filling approximately 50% of the free space in roller bearings and 65% of adjacent areas. For ATEX units, the interval is 2 years or 18,000 hours and must be performed by a service technician.
This prevents installation residues and debris from entering the pump during initial running-in. After 100 hours, the strainer should be removed or cleaned as appropriate.
Selection & Integration Q&A
Choose the 2BV5111 when your vacuum demand requires a 7.5 kW motor at 50 Hz, offering more capacity than the 5.5 kW 2BV5110 but less than the 11 kW 2BV5121. The 2BV5121 is also available as a liquid-ring compressor, so select it if you need compressing duty; the 2BV5111 is primarily a vacuum pump.
Piping must be aligned without stress, and tightening torque at the suction and discharge connections must not exceed 100 Nm. Use appropriate gaskets and ensure the pipes are supported independently to avoid transferring loads to the pump casing.
The standard ambient temperature range is +5 °C to +40 °C, and the maximum installation altitude is 1000 m above sea level. For outdoor installation, provide protection against weather and ensure the IP55 motor is suitable; for altitudes above 1000 m, consult the manufacturer for derating.
The base delivery does not include the operating-liquid separator, intake strainer, or monitoring sensors (flow, level, pressure) required for ATEX or automatic operation. Bearings require periodic greasing with UNIREX N3, and a spare parts kit including seals and gaskets is recommended for service.