Elmo Rietschle L-BV5 2060
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle L-BV5 2060

Elmo Rietschle L-BV5 2060 — Liquid Ring Vacuum Pumps.

The L-BV5 2060 is an ATEX-certified liquid ring vacuum pump (internal 2G, T4) from the L-BV5 series, built for occasional explosive gas/vapour atmospheres. It operates with an operating liquid between +5 °C and +65 °C (nominal +15 °C) and requires suction pressure at least 50 mbar above the vapour pressure. Its primary purpose is safe, reliable vacuum generation in process systems where direct VFD operation is prohibited and independent monitoring of liquid feed and level is mandatory.

Elmo Rietschle L-BV5 Series — Model Comparison & Selection

Model Motor power, kWOperating principleNoise level, dBPower supplyPumping speed, m³/hWeight, kg
L-BV5 2060 Current ——————
2BV5110 5.5ring blow67AC—67
2BV5111 7.5Liquid ring723~ AC—124
2BV5121 11Liquid ring compressor70AC40—
2BV5131 15Liquid ring74AC17.4178
2BV5161 15Liquid ring74AC500160

Full specifications

Operating Conditions, Environment & Protection
Operating temperature +65 °C

Description

Construction and series positioning

Behaviour under load and media

Installation, connection and control

Integration & Operating Notes

Process Limits
Suction pressure must stay 50 mbar above vapour pressure

If the suction pressure falls to within 50 mbar of the operating fluid's vapour pressure, cavitation and loss of ring integrity occur. The manufacturer must be consulted before operating outside this margin, and any change of media or temperature requires re-evaluation.

Operating Instructions — L-BV2 ATEX (EN), Concerning 3.3 / p.5
Control & I/O
Liquid feed and level monitoring must be independent

The flow monitor must trip at ≤50 % of design operating fluid flow, and the level monitor must only permit start-up when the level is between 75 mm and 95 mm. These two monitoring paths must be fully independent, even when implemented in a computer-programmed control, to avoid a common-cause failure.

Operating Instructions — L-BV2 ATEX (EN), Concerning 5.2.3 / p.5–6 and Fig. 2 / p.7
Electrical
Frequency converter operation is not permitted

The motor must be connected directly to the supply. Using a VFD is a forbidden misuse under the ATEX approval and can lead to unacceptable temperature rises or ignition hazards. Ensure the motor protection and cabling follow the separate drive motor manual.

Operating Instructions — L-BV2 ATEX (EN), Concerning 5.3.2 / p.8
Mounting
Verify bleeder resistance < 10^6 Ohm after assembly

Each installed accessory and the pump itself must have a bleeder resistance below 10^6 Ohm to ground. This must be measured after final assembly, as electrostatic charging from isolated metal parts can create an ignition risk in the ATEX zone.

Operating Instructions — L-BV2 ATEX (EN), Concerning 5.1 / p.5
Process Limits
Operating liquid temperature window is +5 to +65 °C

The cooling/feed system must maintain the operating liquid within this range, with +15 °C as the nominal design point. Exceeding +65 °C risks seal damage and invalidates ATEX compliance.

Operating Instructions — L-BV2 ATEX (EN), Concerning 3.3 / p.5 and 5.2.3 / p.6
Maintenance
Weekly dust removal and bearing service every 2 years

Remove dust from the unit weekly. Ball bearings must be re-greased or replaced by a service technician every 2 years or 18,000 operating hours. The operator may not carry out any maintenance requiring dismantling of the machine.

Operating Instructions — L-BV2 ATEX (EN), Concerning 9.1 / p.8
Process Limits
Suction-side separator must be pressure-resistant

If a suction-side separator is required, it must be a pressure-resistant construction per 2014/68/EU; the standard catalogue 2BX separator must not be used. This ensures the separator can withstand the vacuum and potential pressure surges without failure.

Operating Instructions — L-BV2 ATEX (EN), Concerning 5.2.4 / p.8

Selection & Integration Q&A

When should I choose the L-BV5 2060 instead of a larger sibling like the 2BV5121 or 2BV5131?

Choose the L-BV5 2060 for lower flow vacuum duty in ATEX zone 2G with a compact liquid level window (75–95 mm). Larger siblings 2BV5121 (11 kW, 40 m³/h) and 2BV5131 (15 kW) suit higher capacity but have different level windows and may not be available in the same ATEX variant. The 2060 is not available in the corrosion-resistant construction; for aggressive media, select 2BV2070 or 2BV2071.

What are the requirements for the discharge-side pressure monitoring and the operating liquid feed system?

Install pressure monitor G2 downstream of the gas output flange; it must switch off the unit if p2 max is exceeded. The operating liquid feed monitor must trip at ≤50 % of design flow, and the liquid level monitor must only allow start-up between 75 mm and 95 mm. Both monitoring systems must be independent and function even under computer control.

What are the mounting and environment limits for the L-BV5 2060?

The unit is approved for ATEX category 2G (internal T4, surrounding T3) and may only be installed where explosive gas/vapour atmospheres occur occasionally; zone 0 is forbidden. Bleeder resistance to ground must be < 10^6 Ohm for the unit and each attached accessory. Ambient temperature must respect the T3 limit, and the operating liquid must stay within +5 to +65 °C.

What maintenance is required and which accessories are not included in the base delivery?

Weekly dust removal and ball bearing service every 2 years or 18,000 operating hours by a service technician are mandatory. The base delivery does not include monitoring sensors (flow, level, temperature, pressure), pressure-resistant suction-side separator, or the 2BX series operating fluid separator; these must be ordered separately. Note that independent monitoring of operating liquid feed and level is compulsory for safe operation, so the required sensors must be supplied and installed even though they are not part of the base delivery. The standard catalogue separator is not permitted for suction-side use.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — L-BV2 ATEX (EN)
Manual ·951,4 КБ ·12 pp.
View PDF